Kohler 76331-CP

Kohler 76331-CP Shower Arm with 2-Way Diverter Instruction Manual

Model: 76331-CP | Brand: Kohler

1. محصول ختم شوview

The Kohler 76331-CP Shower Arm with 2-Way Diverter is a wall-mount fixture designed to direct water flow between a showerhead and a handshower. Constructed from brass, this unit features a polished chrome finish, engineered to resist corrosion and tarnishing. It includes a flange for installation and is compatible with standard 1/2-inch NPT connections.

Kohler 76331-CP Shower Arm with 2-Way Diverter in Polished Chrome

Image 1.1: The Kohler 76331-CP Shower Arm with 2-Way Diverter, showcasing its polished chrome finish and integrated diverter mechanism.

2. د خوندیتوب معلومات

  • تل د نصب یا ساتنې له پیل کولو دمخه د اوبو اصلي رسولو بند کړئ.
  • مناسب شخصي محافظتي تجهیزات واغوندئ، لکه د خوندیتوب شیشې او دستکشې.
  • که تاسو د نصبولو پروسې د کومې برخې په اړه ډاډه نه یاست، نو د وړ نل لیکونکي سره مشوره وکړئ.
  • ډاډ ترلاسه کړئ چې ټولې اړیکې خوندي دي ترڅو د لیکیدو مخه ونیول شي.
  • Do not overtighten connections, as this can damage the product or plumbing.

3. د بسته محتويات

د نصبولو پیل کولو دمخه ډاډ ترلاسه کړئ چې ټولې برخې شتون لري.

  • Shower Arm with 2-Way Diverter
  • فلج

Note: Showerheads, handshowers, and additional flanges (K-76334 Traditional flange, K-76335 Square flange) are sold separately.

4. مشخصات

فیچرتفصیل
جوړونکیکوهلر
د ماډل شمیره76331-CP
برخه شمیره76331-CP
موادد پیتل جوړول
ختمپولش کروم
د نصبولو طریقهدیوال نصب شوی
د پیوستون ډول1/2 انچه NPT
ځانګړي ځانګړتیاوېDiverter Function
د توکي وزن۲.۴۵ پونډه
د محصول ابعاد4.75 x 3.06 x 12.93 انچه
د جریان کچهپه هره دقیقه کې 2.5 ګیلن

5. د نصبولو لارښوونې

۳.۲ اړین وسایل او توکي (شامل نه دي)

  • د تنظیم وړ رنچ
  • د نل لیکې ټیپ (د تار سیلنټ)
  • نرم ټوکر

5.2 د نصبولو مرحلې

  1. د اوبو رسولو بندول: Locate and turn off the main water supply to your shower area. Open existing shower faucets to relieve pressure.
  2. د شاور موجوده بازو لرې کړئ (که چیرې تطبیق شي): Unscrew the existing shower arm from the wall fitting. Clean any old sealant or debris from the wall pipe threads.
  3. Prepare New Shower Arm: Apply plumber's tape clockwise around the threaded end of the new Kohler shower arm (the end that connects to the wall). Ensure several wraps for a watertight seal.
  4. فلانج نصب کړئ: Slide the decorative flange over the shower arm, ensuring it faces the wall.
  5. Attach Shower Arm to Wall: Carefully thread the shower arm into the 1/2-inch NPT wall fitting. Hand-tighten first, then use an adjustable wrench to tighten an additional 1/2 to 1 full turn until secure and properly oriented. Do not overtighten.
  6. د موقعیت فلانج: د خلاصیدو د پوښلو لپاره د فلانج فلش د دیوال په وړاندې وغورځوئ.
  7. Install Showerhead and Handshower: Attach your desired showerhead to the top outlet and your handshower hose to the bottom outlet of the diverter. Apply plumber's tape to these connections as well.
  8. د لیکونو لپاره ازموینه: Slowly turn the main water supply back on. Check all connections for leaks. If leaks occur, turn off water, tighten connections slightly, and re-test.

6. عملیاتي لارښوونې

The 2-way diverter allows you to easily switch water flow between your main showerhead and a connected handshower.

  • To use the Showerhead: Ensure the diverter handle is in the position that directs water upwards to the showerhead.
  • To use the Handshower: Rotate the diverter handle to the position that directs water downwards to the handshower.
  • To turn off water: Use your shower's main faucet handle to stop the water flow. The diverter only controls the direction of water, not the on/off function or temperature.

7. ساتنه او پالنه

  • پاکول: پالش شوی کروم پای د نرم، d سره پاک کړئamp ټوکر. د خړوبولو پاکوونکو، سختو کیمیاوي موادو، یا د پاکولو پیډونو څخه ډډه وکړئ، ځکه چې دا کولی شي پای ته زیان ورسوي.
  • د ځای پاکول: For water spots, use a mild soap solution and rinse thoroughly with clean water, then dry with a soft cloth.
  • منظم معاینه: Periodically check connections for any signs of leaks or corrosion.

8. ستونزه حل کول

ستونزهاحتمالي لاملد حل لاره
د اړیکو څخه اوبه لیکیږيLoose connections; insufficient plumber's tapeTurn off water supply, tighten connections, reapply plumber's tape if necessary.
Diverter not switching flow completelyDebris in diverter mechanism; worn internal componentsFlush the system by running water through both outlets. If problem persists, contact Kohler customer support.
د اوبو ټیټ فشارMain water supply issue; clogged showerhead/handshowerCheck household water pressure. Clean or replace showerhead/handshower if clogged.

9. تضمین او ملاتړ

For specific warranty information and customer support, please refer to the official Kohler website or contact Kohler directly. Keep your purchase receipt for warranty claims.

د کوهلر رسمي Webسایټ: www.kohler.com

© 2023 Kohler Co. ټول حقونه خوندي دي.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.