1. پیژندنه

The AUTOOL LM120 Digital Manifold Gauge is an intelligent electronic instrument designed to assist in the installation, testing, and maintenance of refrigeration equipment. This includes systems such as air conditioners, refrigerators, and cold storage units. It provides precise measurements for pressure, temperature, and vacuum, along with advanced diagnostic capabilities.

AUTOOL LM120 Digital Manifold Gauge with hoses connected to a car's AC system

Image 1.1: AUTOOL LM120 Digital Manifold Gauge in use, connected to an automotive air conditioning system.

2. د خوندیتوب معلومات

مهرباني وکړئ د وسیلې له چلولو دمخه د خوندیتوب ټولې لارښوونې ولولئ او پوه شئ. د دې لارښوونو په تعقیب کې پاتې راتلل ممکن تجهیزاتو ته زیان یا زیان ورسوي.

  • Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working with refrigeration systems and refrigerants.
  • Ensure adequate ventilation in the work area to prevent the accumulation of refrigerant gases.
  • وسیله د سختې تودوخې، مستقیم لمر وړانګو، یا زنګ وهونکي چاپیریال سره مه مخ کوئ.
  • Handle refrigerant hoses and connections with care to prevent leaks and accidental discharge.
  • Refer to local regulations and industry standards for the safe handling, recovery, and disposal of refrigerants.
  • د وسیلې د ترمیم یا ترمیم هڅه مه کوئ. د خدماتو لپاره وړ پرسونل سره اړیکه ونیسئ.

3. محصول ختم شوview او اجزا

The LM120 Digital Manifold Gauge features a robust design with an intuitive interface. Familiarize yourself with the components shown below.

Diagram of AUTOOL LM120 Digital Manifold Gauge with numbered components

Image 3.1: Detailed diagram of the LM120 Digital Manifold Gauge components.

  1. هک
  2. Clamp-on Temperature Probe Socket
  3. د LCD نندارې
  4. د فعالیت تڼۍ
  5. د چلولو/بندولو تڼۍ
  6. د صفر تtonۍ
  7. R+/R- Refrigerant Type Selection Buttons
  8. د کمولو تڼۍ
  9. د واحد تڼۍ
  10. ° C / ° F تtonۍ
  11. د بریښنا تڼۍ
  12. د ټیټ فشار والو
  13. Refrigerant Observation Window
  14. د لوړ فشار والو
  15. 1/4 inch Low Pressure Inlet
  16. د ریلیف والو
  17. 1/4 inch High Pressure Inlet
  18. Refrigerant Inlet / Vacuum Pump Inlet

4. ترتیب کول

Before first use, ensure the device is ready for operation.

4.1 ابتدايي پاور آن

  • فشار ورکړئ او ونیسئ د بریښنا تڼۍ (11) to turn on the device.
  • The LCD Display (3) will illuminate and show the initial readings.

۴.۲ د نلیو نښلول

Connect the appropriate refrigeration hoses to the inlets on the manifold gauge.

  • Connect the low-pressure hose to the 1/4 inch Low Pressure Inlet (۵۶) .
  • د لوړ فشار نلی سره وصل کړئ 1/4 inch High Pressure Inlet (۵۶) .
  • Connect the service hose (for vacuum pump or refrigerant tank) to the Refrigerant Inlet / Vacuum Pump Inlet (۵۶) .
  • ډاډ ترلاسه کړئ چې ټولې اړیکې ټینګې دي ترڅو د لیکیدو مخه ونیول شي.

4.3 Connecting Temperature Probes (Optional)

For dual temperature measurement, connect compatible clamp-on temperature probes (not included) to the Clamp-on Temperature Probe Socket (۵۶) .

5. عملیاتي لارښوونې

This section details the various functions and how to operate the AUTOOL LM120.

5.1 ښکاره کولview

The large LCD provides clear, real-time data for pressure, temperature, and other parameters.

Close-up of the AUTOOL LM120 Digital Manifold Gauge's smart digital display showing pressure and temperature readings

Image 5.1: The smart digital display provides clear readings for various parameters.

5.2 د واحد انتخاب

To change pressure or temperature units:

  • فشار ورکړئ د واحد تڼۍ (9) to cycle through available pressure units (e.g., Kpa, Psi, Bar).
  • فشار ورکړئ ° C / ° F تtonۍ (10) to switch between Celsius and Fahrenheit temperature displays.

5.3 Refrigerant Type Setting

The device has a built-in database of 89 refrigerants. Select the correct refrigerant type for accurate calculations.

AUTOOL LM120 Digital Manifold Gauge showing refrigerant type R11 on its display

Image 5.2: Setting the refrigerant type on the LM120 display.

  • د کارولو R+/R- Refrigerant Type Selection Buttons (7) to scroll through the available refrigerant types.
  • خپل انتخاب تایید کړئ.

5.4 د فشار اندازه کول

The LM120 measures both high and low pressures simultaneously.

  • Ensure hoses are correctly connected to the high and low-pressure ports of the system.
  • The display will show the current high and low pressure readings.

5.5 دحرارت اندازه کول

With optional clamp-on temperature probes, the device can measure dual temperatures.

AUTOOL LM120 Digital Manifold Gauge displaying T1 Sensor and T2 Sensor temperatures

Image 5.3: High/Low pressure temperature test display.

  • Attach the temperature probes to the desired measurement points (e.g., suction line, liquid line).
  • The display will show T1 and T2 temperature readings.

5.6 Evaporation Pressure & Temperature Test

This function measures the maximum pressure when the refrigerant changes from liquid to gas and the lowest temperature when the liquid becomes gaseous.

AUTOOL LM120 Digital Manifold Gauge displaying evaporation pressure and temperature test results

Image 5.4: Evaporation pressure and temperature test results on the display.

5.7 Condensing Pressure & Temperature Test

This function measures the minimum pressure when the refrigerant changes from gas to liquid and the maximum temperature when the gas changes to liquid.

AUTOOL LM120 Digital Manifold Gauge displaying condensing pressure and temperature test results

Image 5.5: Condensing pressure and temperature test results on the display.

5.8 Pressure Leakage Test

The device can perform a pressure leakage test, recording leak time and speed.

AUTOOL LM120 Digital Manifold Gauge displaying pressure leakage test results with time and pressure values

Image 5.6: Pressure leakage test in progress, showing initial and current pressure values over time.

  • Connect the gauge to the system to be tested.
  • فشار ورکړئ د فعالیت تڼۍ (4) to navigate to the leakage test mode.
  • Follow the on-screen prompts to start and monitor the test. The device calculates the pressure difference between the initial and second test pressures to determine if refrigerant is leaking.

5.9 د خلا اندازه کول

The LM120 can measure the percentage of vacuum achieved in a system.

  • Connect the vacuum pump to the Refrigerant Inlet / Vacuum Pump Inlet (۵۶) .
  • Activate the vacuum pump and monitor the vacuum percentage په ننداره کې.

5.10 Superheat and Subcooling Calculation

Leveraging its integrated 89-type refrigerant database, the LM120 can automatically calculate superheat and subcooling temperatures.

Table showing 89 types of refrigerant data built into the LM120 Digital Manifold Gauge

Image 5.7: Built-in database of 89 refrigerant types for accurate calculations.

  • Ensure the correct refrigerant type is selected (refer to Section 5.3).
  • With pressure and temperature probes connected, the device will display calculated superheat and subcooling values.

6. ساتنه

Proper maintenance ensures the longevity and accuracy of your LM120 Digital Manifold Gauge.

  • پاکول: وسیله په نرم، وچ ټوکر سره پاک کړئ. د کثافاتو پاکوونکي یا محلولونه مه کاروئ.
  • ذخیره کول: Store the gauge in its original case or a protective container in a cool, dry place away from direct sunlight and extreme temperatures.
  • د نلی معاینه: Regularly inspect refrigerant hoses for cracks, wear, or damage. Replace damaged hoses immediately.
  • د پیوستون چک: Ensure all connections and valves are clean and free of debris.

7. ستونزه حل کول

If you encounter issues with your LM120, refer to the following common problems and solutions.

ستونزهاحتمالي لاملد حل لاره
وسیله فعاله نه دهLow or depleted internal battery; power button not pressed correctly.Ensure the device is charged or has sufficient power. Press and hold the Power Button firmly.
د فشار/تودوخې ناسمې لوستلIncorrect refrigerant selected; loose hose connections; faulty probes; sensor calibration needed.Verify the correct refrigerant type. Check all hose connections for tightness. Ensure temperature probes are clean and properly connected. Perform a zero calibration if available (using Zero Button).
ښودنه تیاره یا د لوستلو وړ نه دهBacklight off; low battery.Press the Dimming Button (8) to adjust backlight. Ensure the device is charged.
Leakage test shows false positive/negativeImproper connection; external temperature fluctuations; insufficient test duration.Ensure all connections are absolutely leak-free. Conduct the test in a stable environment. Allow sufficient time for the test to complete.

8. مشخصات

Detailed technical specifications for the AUTOOL LM120 Digital Manifold Gauge.

فیچرمشخصات
جوړونکیAUTOOL
د ماډل شمیرهLM120
موادHigh-strength Engineering Plastic
د فشار ازموینې حد0 Kpa - 6000 kpa
د فشار ازموینې حل1 Kpa
د فشار ازموینې دقت+/- 0.5 %(FS) + 5dgt
د فشار د زیاتولو حد10000 Kpa (10 Mpa; 100 bar)
Number of Refrigerants in Database۴ ډوله
د انٹرفیس معیاري1/4 انچه
ابعاد (L x W x H)20.32 x 7.62 x 12.7 سانتي متره (8 x 3 x 5 انچه)
وزن۵۸.۹۷ ګرامه (۲.۰۸ اونس)
اجزا شامل دي1 set of LM120 Digital Refrigeration Manifold Gauge
بیټرۍ ته اړتیا دهNo (implies internal rechargeable or power source)
UPC733810026709، 733810026198

9. تضمین او ملاتړ

AUTOOL is committed to providing high-quality products and customer satisfaction.

  • د درې کلن تضمین: For damage caused by non-human factors, AUTOOL promises to resend parts free of charge within 3 years from the date of purchase.
  • Permanent Maintenance: The product is covered by permanent maintenance support.
  • د پیرودونکي ملاتړ: For any inquiries, technical assistance, or warranty claims, please contact AUTOOL customer support. You can expect a response within 24 hours.