1. پیژندنه

The daier XH-M609 is a DC 12V-36V battery low voltage disconnect protection module designed to prevent batteries from over-discharging. This module automatically disconnects the load when the battery voltage drops below a user-defined threshold, thereby extending battery lifespan and preventing damage. It is suitable for various types of storage batteries and lithium batteries.

مخکی view of the daier XH-M609 module with a digital display showing '8.8.8' and two buttons.

شکل 1: مخکی view of the XH-M609 module, showing the digital display, input/output terminals, and control buttons.

2. ځانګړتیاوې

  • پراخه ټوکtagد لړيو: Operates with DC 12V to 36V power supplies.
  • د تنظیم وړ محافظت: User-configurable low voltage disconnect threshold.
  • Automatic Disconnect: Automatically cuts off power to the load when battery voltage ډیر ټیټ دی.
  • ډیجیټل ډیزاین: Integrated LED display for real-time voltagڅارنه.
  • د بریښنا ټیټ مصرف: Consumes less than 1.5W.
  • پراخه مطابقت: Suitable for various battery types, including lead-acid and lithium batteries.

3. مشخصات

Table of parameters for the XH-M609 module, listing product name, model, power supply voltage، د محصول حجمtage, control precision, power consumption, scope of application, net weight, and size.

Figure 2: Detailed specifications of the XH-M609 module.

پیرامیټرارزښت
د محصول نومBattery Overdischarge Protection Module
ماډلد XH-M609 معرفي کول
د بریښنا رسولو Voltageډي سي ۱۲ ولټه - ۲۴ ولټه
د محصول VoltageEqual to supply voltage
د کنټرول دقیقیت0.1 وی
د بریښنا مصرفله 1.5 W څخه کم
د غوښتنلیک ساحهد ذخیره کولو مختلفې بیټرۍ، لیتیم بیټرۍ
خالص وزن28 ګرامه
ابعاد (L x W x H)57 x 42 x 19 mm
د کڅوړې ابعاد4.65 x 2.56 x 0.59 انچه
د توکي وزن1.76 اونس
Technical drawing showing the dimensions of the XH-M609 module in millimeters, including overall length, width, and height of components.

Figure 3: Dimensional drawing of the XH-M609 module.

4. سیټ اپ او ویرینګ

Proper wiring is essential for the correct operation of the XH-M609 module. Refer to the wiring diagram below for connection instructions.

  1. Input Power (VIN): Connect your DC 12V-36V battery or power source to the 'VIN' terminals. Ensure correct polarity: '+' to positive, '-' to negative.
  2. Output Load (VOUT): Connect your load (e.g., pump, light, inverter) to the 'VOUT' terminals. Ensure correct polarity: '+' to positive, '-' to negative. The module will control the power to this load.
Wiring diagram showing a storage battery connected to the VIN terminals of the XH-M609 module, and an output power device (like a pump) connected to the VOUT terminals.

Figure 4: Wiring diagram for the XH-M609 module. Connect the battery to 'VIN' and the load to 'VOUT'.

مهم: Always ensure power is disconnected before making any wiring changes to prevent short circuits or damage to the module and connected devices.

۵. عملیات او پروګرام کول

The XH-M609 module features two buttons, '+' and '-', for setting the protection voltage and return difference (hysteresis).

Close-up of the XH-M609 module's digital display showing '10.2' and instructions for the '+' and '-' buttons. '+' button: press once to display protection value, long press to set. '-' button: press once to display return difference value, long press to set.

Figure 5: Button functions for setting protection and return difference values.

Setting the Low Voltage Disconnect (Protection) Value:

  1. Display Protection Value: په لنډه توګه '+' button once. The current low voltage disconnect value will be displayed.
  2. Set Protection Value: فشار ورکړئ او ونیسئ '+' button for approximately 3 seconds. The display will start flashing, indicating it is in setting mode.
  3. وکاروئ '+' او '-' buttons to adjust the desired low voltage disconnect threshold. This is the voltage at which the module will cut off power to the load.
  4. Once the desired value is set, wait a few seconds without pressing any buttons. The display will stop flashing, and the setting will be saved automatically.

Setting the Return Difference (Hysteresis) Value:

The return difference, also known as hysteresis, is the voltage difference between the disconnect voltage and the reconnect voltage. د مثال لپارهample, if the disconnect is set to 10.0V and the return difference is 2.0V, the load will reconnect when the battery reaches 12.0V.

  1. Display Return Difference Value: په لنډه توګه '-' button once. The current return difference value will be displayed.
  2. Set Return Difference Value: فشار ورکړئ او ونیسئ '-' button for approximately 3 seconds. The display will start flashing.
  3. وکاروئ '+' او '-' buttons to adjust the desired return difference value.
  4. Once the desired value is set, wait a few seconds without pressing any buttons. The display will stop flashing, and the setting will be saved automatically.

والیtage Calibration (Advanced):

Some users have reported slight inaccuracies in voltage readings. If precise calibration is required, a common method involves:

  1. فشار ورکړئ او ونیسئ '+' button for approximately 3 seconds until the offset voltage is displayed (e.g., '000').
  2. وکاروئ '+' or '-' buttons to adjust this offset value to match a known accurate voltmeter reading. Setting it to '000' typically means no offset.
  3. Wait for the display to stop flashing to save the setting.

6. ساتنه

The XH-M609 module is designed for reliable operation with minimal maintenance. Follow these guidelines:

  • پاک ساتل: Ensure the module is free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning.
  • د چاپیریال شرایط: Operate the module within its specified temperature and humidity ranges. Avoid extreme heat, cold, or direct sunlight.
  • خوندي اړیکې: Periodically check all wiring connections to ensure they are tight and free from corrosion. Loose connections can lead to intermittent operation or damage.
  • د فزیکي زیان څخه مخنیوی وکړئ: Protect the module from impacts or excessive vibration.

7. ستونزه حل کول

If you encounter issues with your XH-M609 module, consider the following troubleshooting steps:

  • موډل فعال نه دی:
    • د ننوتلو حجم چیک کړئtage (VIN) to ensure it is within the 12V-36V range.
    • Verify that the power supply is connected with correct polarity.
    • Inspect wiring for any breaks or loose connections.
  • Load Not Disconnecting/Reconnecting:
    • Confirm that the protection voltage and return difference values are set correctly.
    • Use a separate voltmeter to verify the actual battery voltage against the module's display. If there's a significant discrepancy, consider voltage calibration (Section 5).
    • Ensure the load's current draw does not exceed the module's relay capacity (typically 20A).
  • ناسم والیtage لوستل:
    • Perform the voltage calibration procedure as described in Section 5.
    • Ensure stable input power. Fluctuations can affect readings.
  • Module Drains Battery After Disconnect:
    • The module itself has a small power consumption (<1.5W). For long-term storage or very sensitive applications, it may be necessary to completely disconnect the battery from the module when not in use.

8. د خوندیتوب معلومات

  • This module operates with DC voltage. Always observe correct polarity when connecting power and loads. Incorrect wiring can damage the module or connected devices.
  • د اعظمي ان پټ حجم څخه ډیر مه کوئtage د 36V DC.
  • Ensure the load current does not exceed the relay's rated capacity (typically 20A).
  • Keep the module away from water, flammable materials, and high temperatures.
  • Do not attempt to modify or disassemble the module. This may void any potential warranty and could lead to malfunction or injury.
  • Installation should be performed by individuals familiar with basic electronics and electrical safety practices.

9. تضمین او ملاتړ

Specific warranty information for the daier XH-M609 module is not provided in this manual. Please refer to the product packaging or contact your retailer for details regarding warranty coverage and technical support.