Dexcom G6 Transmitter

Dexcom G6 Transmitter Device User Manual

Your guide to understanding and using the Dexcom G6 Transmitter.

Introduction to the Dexcom G6 Transmitter

The Dexcom G6 Transmitter is a key component of the Dexcom G6 Continuous Glucose Monitoring (CGM) System. It is designed to send glucose readings wirelessly from the Dexcom G6 sensor to a compatible display device, such as a smartphone or a Dexcom receiver. This manual provides essential information for the safe and effective use of your Dexcom G6 Transmitter.

It is crucial to read and understand all instructions before using the Dexcom G6 Transmitter. If you have any questions or concerns, please contact Dexcom Technical Support or your healthcare professional.

چمتو کول

Before you begin, ensure you have all components of your Dexcom G6 System: a Dexcom G6 Transmitter, a Dexcom G6 Sensor, and a compatible display device (smartphone with Dexcom G6 app or Dexcom G6 receiver).

1. Transmitter Activation

  1. Locate the Transmitter Serial Number: The serial number (SN) is printed on the back of the transmitter. You will need this for pairing.
  2. سینسر چمتو کړئ: Follow the instructions provided with your Dexcom G6 Sensor to insert it into your skin.
  3. ټرانسمیټر ضمیمه کړئ: Once the sensor is inserted, snap the transmitter into the sensor holder. You should hear a click, indicating it is securely attached.
  4. جوړه کول پیل کړئ:
    • For Smartphone App: Open the Dexcom G6 app, navigate to the 'Settings' or 'Pair New Transmitter' section, and enter the transmitter serial number when prompted.
    • د اخیستونکي لپاره: Turn on your Dexcom G6 receiver, go to 'Settings', then 'Transmitter', and select 'Pair New'. Enter the transmitter serial number.
  5. Wait for Pairing Confirmation: The system will attempt to pair with the transmitter. This may take a few minutes. Once paired, the app or receiver will confirm successful connection and begin the 2-hour sensor warm-up period.

مهم: The transmitter is designed for single-patient use and is not reusable after its operational life ends (approximately 3 months).

Operating the Dexcom G6 System

The Dexcom G6 Transmitter works automatically once paired and attached to a sensor. It continuously sends glucose data to your display device.

1. Glucose Readings

  • The transmitter sends a new glucose reading every 5 minutes.
  • These readings are displayed on your compatible smartphone app or Dexcom receiver.
  • Trends and arrows indicate the direction and rate of glucose change.

۶. خبرتیاوې او الارمونه

The Dexcom G6 System provides customizable alerts for high and low glucose levels, as well as a 'Urgent Low Soon' alert. The transmitter facilitates these alerts by sending data to your display device, which then triggers the audible or vibratory notifications.

  • Urgent Low Soon Alert: Notifies you when your glucose is predicted to reach 55 mg/dL (3.1 mmol/L) within 20 minutes. This alert cannot be turned off.
  • Low Glucose Alert: Customizable threshold for low glucose levels.
  • High Glucose Alert: Customizable threshold for high glucose levels.
  • Signal Loss Alert: Notifies you if the transmitter loses communication with your display device.

Refer to your Dexcom G6 app or receiver manual for detailed instructions on customizing alerts.

3. Transmitter Battery Life

The Dexcom G6 Transmitter has a fixed battery life of approximately 3 months (90 days) from activation. It is not rechargeable. Your display device will provide notifications as the transmitter approaches the end of its battery life.

ساتنه

The Dexcom G6 Transmitter requires minimal maintenance. Proper care ensures optimal performance and longevity within its specified lifespan.

1. پاکول

  • If the transmitter becomes soiled, gently wipe it with a damp ټوکر
  • Do not submerge the transmitter in water or use harsh cleaning agents, solvents, or abrasive materials.
  • Ensure the transmitter is dry before reattaching it to a new sensor.

2. ذخیره کول

  • Store unused transmitters in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Do not store transmitters in a refrigerator or freezer.

3. ضایع کول

Once the transmitter battery expires (approximately 3 months after activation), it must be properly disposed of. Do not dispose of the transmitter in household waste. Follow local regulations for electronic waste disposal. Dexcom may offer a return program for used transmitters; check their official webد توضیحاتو لپاره سایټ.

د ستونزو حل کول

This section addresses common issues you might encounter with your Dexcom G6 Transmitter.

1. Signal Loss

If your display device shows a 'Signal Loss' alert:

  • Check Proximity: Ensure your display device is within 20 feet (6 meters) of your transmitter without significant obstructions.
  • Restart Display Device: Try restarting your smartphone or Dexcom receiver.
  • Check Transmitter Connection: Verify that the transmitter is securely snapped into the sensor holder.
  • له لاسوهنې ډډه وکړئ: Keep the display device away from other electronic devices that might cause interference.
  • د لیږدونکي بیټرۍ: If the transmitter is near the end of its 3-month lifespan, signal loss may indicate a low battery. Replace the transmitter.

۶.۳. د جوړې کولو ستونزې

If you are unable to pair a new transmitter:

  • د سریال شمیره تایید کړئ: Double-check that you have entered the correct transmitter serial number.
  • د بلوتوټ ترتیبات: Ensure Bluetooth is enabled on your display device.
  • Forget Device (Smartphone): If previously paired, try "forgetting" the Dexcom G6 transmitter from your smartphone's Bluetooth settings before attempting to pair again.
  • وسیلې بیا پیل کړئ: Restart both your display device and, if possible, the transmitter (by temporarily detaching and reattaching it to the sensor, though this is generally not recommended unless instructed by support).

۳. ناسم لوستل

If you suspect inaccurate glucose readings:

  • Perform a Fingerstick: Compare the Dexcom G6 reading with a blood glucose meter reading.
  • انتظار: Sometimes, readings can fluctuate during the first 24 hours of a new sensor session.
  • اوبه ورکول: Dehydration can affect sensor accuracy. Ensure adequate hydration.
  • Sensor Site: Ensure the sensor is properly adhered and not dislodged.
  • د ملاتړ سره اړیکه: If discrepancies persist, contact Dexcom Technical Support. Do not calibrate the G6 system unless instructed by a healthcare professional or Dexcom support.

مشخصات

فیچرمشخصات
ماډلDexcom G6 Transmitter
د بیټرۍ ژوندApproximately 3 months (90 days)
بې سیم ټیکنالوژيد بلوتوټ ټیټ انرژي (BLE)
د عملیاتي لړۍتر ۴۹.۲۱ فوټو (۱۵ مترو) پورې د لید کرښه
د اوبو مقاومتWater resistant up to 8 feet (2.4 meters) for 24 hours. Do not submerge longer or deeper.
د عملیاتي حرارت درجهله 50°F څخه تر 104°F (10°C څخه تر 40°C)
د ذخیرې د حرارت درجهله 32°F څخه تر 86°F (0°C څخه تر 30°C)

د تضمین معلومات

The Dexcom G6 Transmitter is covered by a limited warranty. The warranty typically covers defects in materials and workmanship for the duration of the transmitter's expected life (approximately 3 months from activation). For specific terms and conditions, please refer to the warranty card included with your product packaging or visit the official Dexcom webسایټ

Keep your purchase receipt and the transmitter serial number as proof of purchase for warranty claims.

د ملاتړ او اړیکو معلومات

For technical assistance, product inquiries, or to report an issue, please contact Dexcom Technical Support.

  • رسمي Webسایټ: www.dexcom.com
  • د پیرودونکي خدمت تلیفون: Refer to the Dexcom website or product packaging for the most current contact numbers for your region.
  • آنلاین سرچینې: The Dexcom website offers FAQs, user guides, and video tutorials.

Always consult your healthcare professional for medical advice and treatment decisions.

© 2024 Dexcom, Inc. All rights reserved. Dexcom and Dexcom G6 are registered trademarks of Dexcom, Inc.

دا لارښود یوازې د معلوماتو لپاره دی او د مسلکي طبي مشورې ځای نه نیسي.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.