Sinocare AQ Smart 25 Kit

Sinocare Safe AQ Smart 25 Kit Blood Glucose Monitoring System User Manual

Model: AQ Smart 25 Kit | Brand: Sinocare

1. پیژندنه

This manual provides essential instructions for the safe and effective use of the Sinocare Safe AQ Smart Blood Glucose Monitoring System. Please read this manual thoroughly before using the device and keep it for future reference. This system is designed for in vitro diagnostic use by individuals for self-testing of blood glucose levels.

Sinocare Safe AQ Smart Glucometer features: SOD Chip, 5s Fast Test, 0.6µl Blood Sample, Easy to Operate, Up to 1000 Test Memory.

Image: Key features of the Sinocare Safe AQ Smart Glucometer, highlighting its advanced technology for fast and easy blood glucose testing.

۲. په بکس کې څه دي؟

The Sinocare Safe AQ Smart 25 Kit includes the following components:

  • 1x Safe AQ Smart Blood Glucose Meter
  • 1x Lancing Device
  • 25x Lancets
  • 25x Test Strips (in vial)
  • 1x بار وړلو کڅوړه
  • 1x د کارونکي لارښود
  • 1x ګړندی لارښود
  • 2x AAA بیټرۍ
Contents of the Sinocare Safe AQ Smart 25 Kit, including the glucometer, lancing device, lancets, test strips, carrying bag, and manuals.

Image: A visual representation of all items included in the Sinocare Safe AQ Smart 25 Kit.

3. ترتیب کول

Follow these steps to prepare your Sinocare Safe AQ Smart system for use:

  1. بیټرۍ نصب کړئ: Open the battery compartment on the back of the meter and insert the two AAA batteries provided, ensuring correct polarity.
  2. Prepare the Lancing Device:
    • د لینډینګ وسیله کیپ خلاص کړئ.
    • یو نوی جراثیمي لانسیټ په ټینګه سره د لانسیټ هولډر کې دننه کړئ.
    • Twist off the protective cap of the lancet and save it for safe disposal.
    • د لانسینګ وسیلې کیپ بدل کړئ.
    • Adjust the puncture depth by rotating the cap. Settings 1-2 are for soft/thin skin, 3 for average skin, and 4-5 for thick/calloused skin.
    • Pull back the cocking barrel until it clicks, indicating it is ready to use.
  3. Insert a Test Strip: Remove one test strip from the vial and immediately close the vial cap tightly. Insert the test strip into the meter's test strip port. The meter will turn on automatically and display a blood drop symbol, indicating it is ready for a blood sample.

Video: A demonstration of the setup process for the Sinocare Safe AQ Smart Blood Glucose Monitoring System, including preparing the lancing device and inserting a test strip.

4. Operating Instructions (Taking a Blood Glucose Test)

Perform the following steps to measure your blood glucose level:

  1. لاسونه وینځئ او وچ کړئ: Wash your hands thoroughly with soap and warm water, then dry them completely. This helps prevent infection and ensures an accurate reading.
  2. Prepare Finger: Use an alcohol swab to clean the fingertip you intend to prick. Allow the alcohol to air dry completely before proceeding.
  3. د وینې ایس ترلاسه کړئampLe: Press the lancing device firmly against the prepared fingertip and press the release button. A small drop of blood will form.
  4. د وینې S تطبیق کړئampLe: Gently touch the tip of the test strip to the blood drop. The strip will automatically draw the blood into the reaction area. Do not smear the blood.
  5. پایله ولولئ: میټر به ستاسو د وینې ګلوکوز پایله په پنځو ثانیو کې ښکاره کړي.
  6. د کارول شویو موادو ضایع کول: Eject the used lancet from the lancing device into a sharps container. Eject the used test strip from the meter into a waste bin.
Step-by-step visual guide for using the Sinocare Safe AQ Smart Glucometer: insert strip, collect blood, apply blood, and view پایله

Image: Visual instructions for performing a blood glucose test with the Sinocare Safe AQ Smart system.

Video: A demonstration of the blood sampling and testing procedure, showing how to obtain a blood drop and apply it to the test strip for a quick result.

5. ساتنه

Proper maintenance ensures the longevity and accuracy of your device:

  • پاکول: Wipe the meter and lancing device with a soft, damp cloth. Do not immerse the device in water or use harsh cleaning agents.
  • ذخیره کول: Store the meter, test strips, and lancing device in their original carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Keep out of reach of children.
  • Test Strip Storage: Always keep test strips in their original vial with the cap tightly closed. Once opened, test strips are typically valid for 6 months. Write the discard date on the vial.

6. ستونزه حل کول

If you encounter any issues with your Sinocare Safe AQ Smart system, please refer to the full user manual for detailed troubleshooting steps. Common issues may include:

  • Error messages on the display.
  • Inaccurate readings (ensure proper technique, fresh test strips, and correct coding if applicable).
  • Device not turning on (check batteries).

For further assistance, contact Sinocare customer support.

7. مشخصات

فیچرتفصیل
د ماډل شمیرهAQ Smart 25 Kit
وینې ایسampد حجم0.6 µL
د ازموینې وخت5 ثانیې
د بیټرۍ ډول2 AAA بیټرۍ (شامل دي)
ابعاد16.5 x 13.5 x 5.2 سانتي متره
وزن290 ګرامه
اصلچین

۱.۱. د خوندیتوب مهم معلومات

This device is intended for monitoring blood glucose levels for individuals with diabetes mellitus. It is crucial to consult with a healthcare professional for diagnosis, treatment, and interpretation of results. Do not use this device for diagnosing diabetes. Always follow your doctor's advice regarding your diabetes management plan. Keep all components out of reach of small children to prevent choking hazards or accidental ingestion.

9. تضمین او ملاتړ

For information regarding product warranty, returns, or technical support, please refer to the warranty card included in your kit or visit the official Sinocare website. Contact details for customer service are typically provided in the full user manual.

© 2023 Sinocare. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.