FACULX W3103 (AC220V 5000W)

FACULX W3103 Digital High-Power Temperature Controller (AC220V 5000W) User Manual

نښه: FACULX | ماډل: W3103 (AC220V 5000W)

1. پیژندنه

This manual provides detailed instructions for the installation, operation, and maintenance of your FACULX W3103 Digital High-Power Temperature Controller. Please read this manual thoroughly before use to ensure proper functionality and safety.

The FACULX W3103 is a versatile digital thermostat designed for precise temperature control in high-power heating applications. It features a wide temperature measurement range, multiple control functions, and flexible power input options.

2. د خوندیتوب معلومات

WARNING: This device operates with high voltage (AC220V) and high power (5000W). Improper installation or use can result in electric shock, fire, or personal injury. Always follow safety guidelines and consult a qualified electrician if unsure.

  • Ensure the power supply is disconnected before any installation, wiring, or maintenance.
  • وسیله په لوند یا d کې مه چلوئamp چاپیریالونه
  • د تارونو ټولې اړیکې د تارونو د ډیاګرام سره سم خوندي او سمې دي.
  • د اعظمي اوسني درجه بندي 30A څخه ډیر مه کوئ.
  • وسیله د سوځیدونکي موادو څخه لرې وساتئ.
  • دا محصول د لوبو نه دی. د ماشومانو د لاسرسي څخه لرې وساتئ.

3. محصول ختم شوview

The FACULX W3103 Digital Temperature Controller features a clear digital display, control buttons, and a remote temperature sensor for accurate readings.

FACULX W3103 Digital Temperature Controller with sensor

شکل 3.1: مخکی view of the FACULX W3103 Digital Temperature Controller with its wired temperature sensor.

مهمې برخې:

  • ډیجیټل ډیزاین: Shows current temperature, set points, and operational status.
  • "Start Setting" Buttons (Up/Down Arrows): Adjust the start temperature.
  • "Stop Setting" Buttons (Up/Down Arrows): Adjust the stop temperature.
  • "SET" Button: د تنظیم کولو حالت ته ننوځي او انتخابونه تاییدوي.
  • د حرارت سینسر: External probe for accurate temperature measurement.
  • د تارونو ټرمینلونه: For power input and load output connections.

4. مشخصات

Refer to the table below for detailed technical specifications of the FACULX W3103 (AC220V 5000W) model.

Dimensions of FACULX W3103 Digital Temperature Controller

شکل 4.1: Physical dimensions of the temperature controller (96mm x 70mm x 46mm).

فیچرمشخصات
د محصول نومد ډیجیټل تودوخې کنټرولر
ماډلW3103
ننوتۍ جلدtage (Current Model)AC 220V
Output Power (Current Model)۲۵۰۰ واټ ( اعظمي ۱۰A)
د فعالیت ډولد حرارت درجه کنټرول
د محصول ډولوالیtage محصول
د کنټرول ډولد موقعیت کنټرول
د اندازه کولو انډولNTC10K / B3435 / L = 1 meter
د حرارت درجه اندازه کول-50 °C څخه تر 110 °C
د تودوخې کنټرول رینج-19 °C څخه تر 99 °C
د تودوخې اندازه کولو دقیقیت± 0.2 °C
د کنټرول دقیقیت۴۵ سانتي ګراد
ابعاد (L x W x H)96 mm x 70 mm x 46 mm
موادپلاستيک، فلزي

5. ترتیب او نصب کول

Careful installation is crucial for the safe and effective operation of the temperature controller. Ensure power is disconnected before proceeding.

Close-up of FACULX W3103 wiring terminals and display

شکل 5.1: تفصيلي view of the controller's wiring terminals and display interface.

د تار لګولو لارښوونې:

  1. د بریښنا رسولو نښلول: Connect the AC 220V power supply to the designated input terminals. Refer to the diagram on the device for correct polarity and terminal identification.
  2. د نښلولو بار: Connect your heating device (load) to the output terminals. Ensure the load's power consumption does not exceed 5000W or 30A.
  3. د سینسر اړیکه: Plug the NTC temperature sensor into its dedicated port. The sensor cable length is 1 meter. Position the sensor in the area where temperature needs to be measured and controlled.
  4. پورته کول: Mount the controller in a suitable, dry location, away from direct heat sources or excessive moisture. Ensure adequate ventilation.

IMPORTANT: Double-check all wiring before applying power. Incorrect wiring can damage the device or connected equipment and poses a safety risk.

6. عملیاتي لارښوونې

Once installed and powered on, the controller will display the current temperature. Follow these steps to set your desired temperature range.

FACULX W3103 Digital Temperature Controller display showing AC220V

شکل 6.1: Controller display indicating AC220V power input and temperature readings.

د تودوخې پیرامیټرې تنظیم کول:

  1. پاور آن: Connect the device to the AC 220V power supply. The display will show the current temperature measured by the sensor.
  2. Set Start Temperature:
    • Press the "SET" button once. The "Start Setting" value will flash.
    • Use the "Start Setting" Up/Down arrow buttons to adjust the desired temperature at which the heating should activate.
    • Press "SET" again to confirm and move to the Stop Temperature setting, or wait a few seconds for it to auto-save.
  3. Set Stop Temperature:
    • After setting the Start Temperature, the "Stop Setting" value will flash.
    • Use the "Stop Setting" Up/Down arrow buttons to adjust the desired temperature at which the heating should deactivate.
    • Press "SET" again to confirm and exit setting mode, or wait a few seconds for it to auto-save.

The controller will now maintain the temperature within the set range. If the current temperature falls below the "Start Setting", the heating element will activate. If it rises above the "Stop Setting", the heating element will deactivate.

Advanced Functions (Intermittent Operation, Timed On/Off):

This model supports advanced functions like intermittent operation and timed on/off settings. Specific instructions for these modes are typically accessed by pressing and holding the "SET" button for several seconds to enter a parameter menu. Refer to the on-screen codes and a more detailed functional diagram (if available with the product packaging) for precise configuration of these advanced features.

7. ساتنه

The FACULX W3103 is designed for reliable operation with minimal maintenance. Regular checks can help ensure its longevity and performance.

  • پاکول: Periodically wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • اړیکې: Annually inspect all wiring connections to ensure they are tight and free from corrosion.
  • سینسر: Ensure the temperature sensor is clean and free from debris that could affect its accuracy. Do not bend or damage the sensor cable.
  • وینټیلیشن: Ensure the controller's ventilation openings are not obstructed to prevent overheating.

د هر ډول ساتنې ترسره کولو دمخه تل بریښنا قطع کړئ.

8. ستونزه حل کول

If you encounter issues with your temperature controller, refer to the following common problems and solutions:

ستونزهاحتمالي لاملد حل لاره
ښودنه بنده دهد برېښنا نشتوالی؛ ناسم تارونه؛ فیوز چاودېدلی.Check power connections; verify wiring; check circuit breaker/fuse.
د تودوخې لوستل ناسم ديSensor damaged or improperly placed; sensor cable faulty.Inspect sensor and cable for damage; reposition sensor; replace sensor if damaged.
د تودوخې وسیله نه چالانیږي/بندیږيIncorrect temperature settings; faulty wiring to load; load malfunction.Verify Start/Stop temperature settings; check load wiring; test heating device independently.
Controller displays "HHH" or "LLL"Temperature sensor open circuit (LLL) or short circuit (HHH); temperature out of range.Check sensor connection; replace sensor if faulty; ensure operating within specified temperature range.

که چیرې د دې حل لارو هڅه کولو وروسته هم ستونزه دوام ومومي، مهرباني وکړئ د پیرودونکو ملاتړ سره اړیکه ونیسئ.

9. تضمین او ملاتړ

This product comes with a standard manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including the warranty period and coverage details.

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your retailer or the manufacturer directly. Keep your purchase receipt and product model information handy when contacting support.

جوړونکی: FACULX

د ماډل شمیره: W3103 (AC220V 5000W)

© 2024 FACULX. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.