This manual provides detailed instructions for the installation, operation, and maintenance of the ZL-R200A Universal Air Source Heat Pump Water Heater Controller. This multi-function controller is designed to optimize the performance and efficiency of air-source heat pump water heaters, offering features such as auxiliary heating, waterflow auditing, ventilation pump control, and various protection mechanisms.
Please read this manual thoroughly before installation and operation to ensure safe and correct usage of the product.
2. کلیدي ځانګړتیاوې
- څو اړخیز ډیزاین: Includes waterflow auditing, ventilation pump control, and sensor failure action functions.
- د تودوخې پوښتنه: Allows checking temperatures from all sensors, with results displayed for 3 seconds.
- د اوبو د حرارت درجه ترتیب: Adjustable temperature range from 10℃ to 70℃ (factory default 40℃).
- دوه کاري طریقې: "AUTO" mode for continuous heating based on settings, and "SAVE" mode for heating only within three predefined time periods.
- Multiple Control Functions: Manages temperature, auxiliary electrical heaters, and water ventilation pump.
- Winter Antifreeze & Auto Defrost:
- Antifreeze pumping activates when outdoor temperature ≤ 2℃ (pump runs 3 minutes every 30 minutes), stopping when ≥ 3℃.
- Auto defrost starts at -9~0℃ and stops at 2-30℃.
- Multiple Protections & Warning: Features exhaust temperature protections, high/low pressure warnings, compressor delay protections, and water sensor failure warnings.
- Auto Restart & Restore: Automatically restarts after power loss, retains power failure memory, and supports recovery to factory settings.



3. نصب او ویرینګ
Proper installation and wiring are critical for the safe and correct operation of the ZL-R200A controller. It is recommended that installation be performed by a qualified technician.
3.1 عمومي احتیاطي تدابیر
- The panel should be installed indoors, not outdoors.
- Do not plug in/out panel bundle with power supplied.
- All sensors must be installed at correct positions.
- Ensure U34 is set correctly; otherwise, the system will not work.
3.2 د تارونو ډیاګرام
Refer to the diagram below for correct wiring connections. Ensure all connections are secure and follow local electrical codes.

4. عملیات
The ZL-R200A controller features an intuitive display and buttons for easy operation.
4.1 د کنټرول پینلview

۵.۲ د اوبو د تودوخې تنظیمول
The water temperature can be set within a range of 10℃ to 70℃. The factory default setting is 40℃.
4.3 کاري طریقې
The controller offers two primary working modes:
- د "آټو" حالت: The system maintains heating according to the set temperature.
- "خوندي کول" حالت: Heating is restricted to three predefined time periods. This mode is designed for energy saving.
To switch between "AUTO" and "SAVE" modes, press the M key. When "Auto restart function" is disabled (U80 = 0), it will be "AUTO" mode after power supplied.
۵.۴.۸ د سیسټم پیرامیټر ترتیبات
To access and modify system parameters:
- مطبوعاتي SET key to set the temperature. Keeping pressed can fast set.
- مطبوعاتي SET key to set the clock. Keeping pressed can fast set. The setting will be saved 5 seconds later after set.
- To enter system parameter set: Press ▲ او ▼ keys simultaneously for 3 seconds. The big digits show "P00" for password edit.
- مطبوعاتي ▲ or ▼ key to set password, press SET تصدیق کول.
- If the password is wrong, exit. Else enter parameter set status.
- مطبوعاتي ▲ or ▼ to select parameter. Press SET to show the value of the parameter.
- مطبوعاتي ▲ or ▼ د ارزښت ټاکلو لپاره. مطبوعاتي SET د پیرامیټر انتخاب ته د بیرته راستنیدو لپاره.
- ساتل SET pressed for 5 seconds to save the setting, and exit.
The status will exit if there is no key operation for 15 seconds, and the settings will not be saved.
د سیسټم پیرامیټر جدول:

ګړی تنظیم
- مطبوعاتي SET کیلي، د ساعت شمیرې به راښکاره شي، فشار ورکړئ ▲ or ▼ د ساعت ټاکلو کیلي.
- مطبوعاتي SET بیا کیلي، دقیقې شمیرې به روښانه شي، فشار ورکړئ ▲ or ▼ د دقیقې ټاکلو لپاره کیلي.
- مطبوعاتي SET د وتلو کلیدي.
Periods Setting for "SAVE" Mode
- ساتل SET key depressed for 3 seconds to enter the period setting status.
- مطبوعاتي SET key to select the period and on/off. Press ▲ or ▼ د وخت ارزښت ټاکلو لپاره.
- ساتل SET key depressed for 3 seconds to save the settings, and exit.
The status will exit if there is no key operation for 15 seconds, and the settings will not be saved.
5. ساتنه
To ensure the longevity and optimal performance of your ZL-R200A controller, follow these general maintenance guidelines:
- Keep the display panel clean and free from dust. Use a soft, dry cloth for cleaning.
- Ensure the controller is installed in a dry, indoor environment to prevent moisture damage.
- په منظم ډول د تارونو ټولې اړیکې د ټینګښت او د اغوستلو یا زنګ وهلو نښو لپاره وګورئ.
- Avoid exposing the unit to extreme temperatures or direct sunlight.
- If any sensors are damaged or malfunctioning, replace them promptly with compatible parts.
6. ستونزه حل کول
This section provides guidance on common issues you might encounter with your ZL-R200A controller.
6.1 عام مسایل او حلونه
| ستونزه | احتمالي لامل | د حل لاره |
|---|---|---|
| سیسټم کار نه کوي | Incorrect U34 setting. | Set U34 correctly as per the System Parameter Table. |
| Real clock loses time | Power loss for more than 72 hours. | Reset the clock. The real clock can only keep running correctly for 72 hours after power supply loses. |
| Sensor failure warning | Sensors not installed correctly or are faulty. | Ensure all sensors are installed at correct positions. Check sensor connections and replace faulty sensors if necessary. |
| ترتیبات خوندي شوي ندي | No key operation for 15 seconds during setting. | Ensure to press and hold the SET key for 5 seconds to save settings before the 15-second timeout. |
| High/Low pressure warning | System pressure issues. | Consult a qualified technician to diagnose and resolve pressure-related problems in the heat pump system. |
7. مشخصات
| پیرامیټر | ارزښت |
|---|---|
| نوم | د اوبو ګرمولو کنټرولر |
| مواد | چاپ شوی سرکټ بورډ |
| د رینجونو ترتیب کول | 10 ℃ تر 70 ℃ |
| د ښودلو لړۍ | -40 ℃ تر 130 ℃ |
| د کار د حرارت درجه | 0-50℃ |
| د ذخیرې د حرارت درجه | -10 ℃ تر 60 ℃ |
| محیطي رطوبت | 20-85%RH without dew |
| د بریښنا رسول | 220VAC ±10%، 50/60Hz |
| Outputs (Compressor) | 30A |
| Outputs (Heaters) | 8A |
| Outputs (Others) | 3A |
| هیسټریسیس | 2~10℃ |
| د اوبو سینسرونو کیلیبریشن | -9.9~ 9.9℃ |
| له حرارت څخه انرژي ترلاسه شوه | -5~ 25℃ |
| د یخ وهلو د پیل وخت | 10-90 دقیقې |
| د یخ وهلو د پیل تودوخه | -9~0℃ |
| د یخ وهلو د بندولو تودوخه | 2~30℃ |
| د یخ وهلو اعظمي وخت | 2-15 دقیقې |
| د اخراج محافظت تودوخه | 50 ~ 125℃ |
| د پینل اندازه ښودل | ۱۶۶ * ۶۹.۵ ملي متره / ۶.۵۳ * ۲.۷۳ انچه |
| Mainboard Size | 105 * 90 * 35mm / 4.13 * 3.54 * 1.39in |
| د بسته وزن | 725g / 1.60lb |
7.1 د بسته محتويات
- 1 * Mainboard
- 1 * Display Panel
- 4 * Temperature Sensors

8. د کارن لارښوونې
- د نسخې چک: If you are replacing an older controller, ensure you have the "New version" ZL-R200A for optimal compatibility and features.
- د بریښنا ضایع: Be aware that the internal clock will only retain its setting for up to 72 hours after a power loss. For extended outages, you may need to reset the clock.
- د سینسر ځای په ځای کول: Correct placement of all four temperature sensors is crucial for accurate readings and proper system operation.
9. تضمین او ملاتړ
For warranty information, technical support, or service inquiries, please contact your original seller or the product manufacturer. Keep your purchase receipt as proof of purchase.