The Behringer XM8500 is a high-performance dynamic cardioid vocal microphone designed for exceptional voice projection and transparent sound reproduction. Its robust construction and advanced features make it suitable for both studio recording and live performance applications. This manual will guide you through the proper setup, operation, and maintenance of your microphone to ensure optimal performance and longevity.
Key features include an ultra-wide frequency response, a cardioid pickup pattern to minimize background noise and feedback, a shock mount system to reduce handling noise, and an integrated spherical wind and pop noise filter. The microphone comes complete with a microphone stand adapter and an impact-resistant carrying case for protection and portability.
2. ترتیب کول
To begin using your Behringer XM8500 microphone, follow these steps for proper connection:
- بسته بندي کول: Carefully remove the microphone and all accessories from the impact-resistant carrying case. Ensure all components are present: the XM8500 microphone, microphone clip, and XLR cable.
- Attaching the Microphone Clip: Securely attach the included microphone clip to a standard microphone stand.
- د مایکروفون نصب کول: Insert the Behringer XM8500 microphone into the microphone clip. Ensure it is firmly seated.
- د XLR کیبل نښلول: Connect the female end of the XLR cable to the XLR connector at the base of the microphone. Connect the male end of the XLR cable to an appropriate input on your audio mixer, audio interface, or ampلايف
- فعالول: If your microphone features an on/off switch, ensure it is in the 'OFF' position before connecting to prevent sudden loud noises. Once connected, switch it to the 'ON' position.



3. عملیاتي لارښوونې
The Behringer XM8500 is designed for straightforward operation. Here are guidelines for optimal use:
- آن/بند سویچ: Locate the slide switch on the microphone body. Slide it to the 'ON' position to activate the microphone. Slide it to 'OFF' when not in use to prevent unwanted noise and conserve connected equipment.
- د مایکروفون ځای پرځای کول: Due to its cardioid pickup pattern, the XM8500 is most sensitive to sound coming from directly in front of it, while rejecting sounds from the sides and rear. For vocals, position the microphone directly in front of the sound source (e.g., your mouth) at a distance of 2-6 inches for a full, rich sound.
- د چاودیدونکو توکو کمول: The integrated spherical wind and pop noise filter helps reduce harsh 'P' and 'B' sounds (plosives). For additional reduction, maintain a slight distance or angle the microphone slightly off-axis.
- Reducing Handling Noise: The internal shock mount system is designed to minimize noise from handling the microphone. For best results, use the microphone clip and stand whenever possible.
4. ساتنه
Proper care and maintenance will extend the life and performance of your microphone:
- پاکول: To clean the microphone grille, gently wipe it with a soft, dry cloth. For stubborn grime, a slightly damp cloth can be used, ensuring no moisture enters the microphone capsule. Do not use harsh chemicals or abrasive cleaners.
- ذخیره کول: When not in use, store the microphone in its provided impact-resistant carrying case. This protects it from dust, moisture, and physical damage. Avoid storing the microphone in extreme temperatures or high humidity.
- د کیبل پاملرنه: Always coil the XLR cable neatly after use to prevent kinks and damage. Avoid pulling on the cable when disconnecting; always grasp the connector itself.


5. ستونزه حل کول
If you encounter issues with your Behringer XM8500, consider the following common troubleshooting steps:
- غږ نشته:
- Ensure the microphone's on/off switch is in the 'ON' position.
- Verify that the XLR cable is securely connected at both the microphone and the input device (mixer/interface).
- Check the input device's gain/volume settings. Increase the gain gradually.
- Test with a different XLR cable or input channel if available.
- ټیټ حجم:
- Increase the gain on your mixer or audio interface. Dynamic microphones often require more gain than condenser microphones.
- Ensure the microphone is positioned close enough to the sound source.
- Feedback (High-pitched squealing):
- مایکروفون د سپیکرو یا مانیټرونو څخه لرې ځای په ځای کړئ.
- Reduce the overall volume or specific frequency bands on your mixer/EQ that are causing the feedback.
- Ensure the microphone is pointed away from speakers, utilizing its cardioid pattern.
- د کنټرول ډیر شور:
- Ensure the microphone is properly seated in its shock mount or clip.
- Minimize physical contact with the microphone body during use.
6. مشخصات
| فیچر | مشخصات |
|---|---|
| د ماډل نوم | XM8500 |
| برانډ | بېرنجر |
| د مایکروفون فارم فکتور | یوازې مایکروفون |
| قطبي بڼه | یو اړخيزه |
| د ارتباط ټیکنالوژي | تارونه |
| د نښلونکي ډول | XLR |
| د تعدد ځواب | له 50 Hz څخه تر 15 kHz پورې |
| د سیګنال څخه تر شور پورې نسبت | 35 dB |
| د توکي وزن | ۱.۶۲ اونس (۰.۱ پونډه) |
| د محصول ابعاد (L x W x H) | 12.2 x 25 x 3.54 انچه |
| مواد | جامع |
| شاملې برخې | Dynamic Cardioid Microphone, Microphone Stand Adapter, Impact-Resistant Carrying Case |
7. تضمین او ملاتړ
For warranty information, technical support, or service inquiries regarding your Behringer XM8500 microphone, please refer to the official Behringer webسایټ ته مراجعه وکړئ یا مستقیم د دوی د پیرودونکي ملاتړ سره اړیکه ونیسئ. د هر ډول تضمین ادعا لپاره د پیرود ثبوت وساتئ.