This manual provides essential instructions for the installation, operation, and maintenance of your Elkay ERS11Y Commercial Remote Chiller. Designed for commercial applications, this unit delivers chilled drinking water efficiently. Please read this manual thoroughly before installation and use to ensure proper function and safety.
محصول پای ته ورسیدview
The Elkay ERS11Y is a compact, remote chiller unit constructed from galvanized steel, suitable for various commercial environments. It is designed to provide a continuous supply of chilled water when connected to a compatible dispenser. This unit is NSF compliant, ensuring it meets public health and safety standards.
- Chilling Capacity: 1.5 gallons per hour (GPH) of 50°F (10°C) drinking water, based on 80°F (26.7°C) inlet water and 90°F (32.2°C) ambient temperature.
- والیtage: 115V
- مطابقت: Designed for use with Elkay Aqua-Chill Dispenser model ELK2156.

Figure 1: Elkay ERS11Y Commercial Remote Chiller. This image displays the compact, galvanized steel construction of the chiller unit, highlighting its vented sides and visible condenser coil.
مشخصات
| جوړونکی | ایلکی |
| د ماډل شمیره | ERS11Y |
| برخه شمیره | ERS11Y |
| ابعاد (H x W x D) | 14 inches (plus 2 inches with supplies) x 7-1/8 inches x 17-1/8 inches |
| وزن | ۲.۴۵ پونډه |
| مواد | جستی فولاد |
| ختم | جستی فولاد |
| والیtage | 115V |
| واټtage | ۴۵ واټه |
| Chilling Capacity | 1.5 GPH (په ساعت کې ګیلن) |
| د بریښنا سرچینه | Corded-electric (requires wiring) |
تنظیم او نصب کول
Proper installation is crucial for the efficient and safe operation of your Elkay ERS11Y chiller. It is recommended that installation be performed by a qualified professional.
د ځای اړتیاوې:
- Install the chiller in a location that allows for adequate ventilation. Restricted airflow can lead to reduced efficiency and potential damage.
- Ensure the surface is level and capable of supporting the unit's weight (33 lbs).
- Maintain sufficient clearance around the unit for air circulation and future maintenance access.
بریښنایی پیوستون:
- The unit requires a 115V electrical supply.
- Wiring should be performed by a licensed electrician in accordance with all local and national electrical codes. The unit typically requires direct wiring rather than a standard plug.
- Ensure the circuit is properly grounded and protected by an appropriate circuit breaker.
د پلمبینګ اتصال:
- Connect the chiller to a potable water supply using appropriate plumbing lines and fittings.
- ډاډ ترلاسه کړئ چې ټولې اړیکې خوندي او له لیک څخه پاک دي.
- Flush the water lines thoroughly before connecting to the chiller to remove any debris.
- The chiller is designed for use with compatible water dispensers, such as the Elkay Aqua-Chill Dispenser ELK2156.
Note: Refer to the specific installation instructions provided with your water dispenser for complete plumbing and electrical diagrams.
عملیاتي لارښوونې
Once properly installed and connected, the Elkay ERS11Y chiller operates automatically to provide chilled water.
- لومړنی پیل: After installation, ensure all water and electrical connections are secure. Turn on the water supply to the unit.
- پاور آن: Activate the electrical supply to the chiller. The unit will begin the chilling cycle.
- لومړی کارول: Allow approximately 30-60 minutes for the chiller to reach its optimal operating temperature and chill the initial volume of water. Dispense a few cups of water to clear any air from the lines and ensure cold water flow.
- اتوماتیک عملیات: The chiller is equipped with a thermostat that automatically cycles the compressor on and off to maintain the desired water temperature.
The unit is designed for continuous operation. If the unit is turned off for an extended period, repeat the initial startup steps.
ساتنه
Regular maintenance ensures the longevity and efficient performance of your chiller. Always disconnect power before performing any maintenance.
- د کنډنسر کویل پاکول: Periodically inspect and clean the condenser coil to remove dust and debris. A dirty coil can reduce cooling efficiency and increase energy consumption. Use a soft brush or vacuum cleaner.
- وینټیلیشن: Ensure that the area around the chiller remains clear and well-ventilated. Do not block air vents.
- Water Line Inspection: Regularly check water lines and connections for any signs of leaks or damage.
- د فین معاینه: Ensure the fan operates freely and is not obstructed. Some user experiences indicate that the fan may need manual adjustment during initial setup to ensure proper clearance.
For any complex maintenance or repairs, contact a qualified service technician.
د ستونزو حل کول
This section addresses common issues you might encounter with your Elkay ERS11Y chiller. For problems not listed here, contact customer support.
| ستونزه | احتمالي لامل | د حل لاره |
|---|---|---|
| No cold water / Water not chilling |
|
|
| واحد ډیر شور دی |
|
|
| د اوبو لیک |
|
|
د تضمین معلومات
Elkay warrants every water cooler, packaged water chiller, fountain, and accessory to be free from defects in material and workmanship under normal use for یو (1) کال from the date of installation or eighteen (18) months from the date of shipment from the factory, whichever occurs first.
Additionally, Elkay warrants the compressor and hermetically sealed refrigeration system, including cooling coils or tank assembly when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship under normal use for an additional four (4) years from the end of the initial one (1) year period.
Note: Packaged water chillers are not subject to the additional four (4) year warranty when used in chilled water commercial/industrial applications other than for potable water.
د پیرودونکي ملاتړ
For further assistance, technical support, or to inquire about service, please contact Elkay customer service or visit their official webسایټ