ایمرسن 3F01-110

د ایمرسن وایټ-راجرز 3F01-110 سنیپ ډیسک فین کنټرول کارونکي لارښود

1. محصول ختم شوview

The White-Rodgers 3F01-110 Snap Disc Fan Control is a reliable thermal switch designed for automatic regulation of fan or blower operation in various heating, ventilation, and air conditioning (HVAC) systems. This control is engineered for quick on-job replacement and features a flanged airstream mount for secure installation.

کلیدي ځانګړتیاوې:

  • Designed for automatic fan or blower control based on temperature.
  • Features a Cut-In temperature of 110°F (43°C).
  • Features a Cut-Out temperature of 90°F (32°C).
  • Flanged airstream mount for easy and secure installation.
  • Mounting holes are compatible with standard 3/4-inch snap discs.
  • Single Pole Single Throw (SPST) contact type.
مخکی view of the White-Rodgers 3F01-110 Snap Disc Fan Control

شکل 1: مخکی view of the White-Rodgers 3F01-110 Snap Disc Fan Control, showing the metallic disc and black base with electrical terminals.

2. د خوندیتوب معلومات

Please read and understand all instructions before installing or operating this product. Failure to follow these instructions may result in property damage, personal injury, or death.

  • د بریښنا خطر: Disconnect all power to the appliance or system before installing or servicing the control. Always use appropriate lockout/tagپروسیجرونه
  • وړ پرسونل: Installation and servicing should only be performed by a qualified, experienced technician.
  • مناسب غوښتنلیک: Ensure this control is suitable for your specific application. Refer to the specifications section for details.
  • تارونه: ټول تارونه باید د محلي او ملي بریښنا کوډونو سره مطابقت ولري.
  • د تودوخې محدودیتونه: Do not expose the control to temperatures outside its specified operating range.

3. ترتیب او نصب کول

This section provides general guidelines for installing the White-Rodgers 3F01-110 Snap Disc Fan Control. Specific installation procedures may vary depending on the appliance or system.

3.1 د نصب کولو دمخه چکونه

  • Verify that the power supply to the appliance is disconnected.
  • Confirm that the 3F01-110 model is the correct replacement or new installation part for your system.
  • Inspect the control for any visible damage before installation.

3.2 پورته کول

The 3F01-110 features a flanged airstream mount and is designed to fit standard 3/4-inch snap disc mounting holes.

  1. Locate the appropriate mounting position within the airstream of the fan or blower, ensuring good thermal contact.
  2. Align the mounting holes on the control's flange with the existing or prepared mounting holes.
  3. Secure the control using appropriate fasteners (not included) to ensure a stable and vibration-free installation.
اړخ view of the White-Rodgers 3F01-110 Snap Disc Fan Control

شکل 2: اړخ view of the White-Rodgers 3F01-110 Snap Disc Fan Control, highlighting the flanged mounting plate and electrical terminals.

3.3 تارونه

The 3F01-110 is a Single Pole Single Throw (SPST) control with Normally Open contacts and screw terminals for electrical connections.

  1. Identify the two electrical terminals on the control.
  2. Connect the appropriate electrical wires from your fan or blower circuit to these screw terminals. Ensure connections are tight and secure.
  3. Verify that all wiring conforms to the appliance's wiring diagram and all applicable electrical codes.
  4. Once wiring is complete and secure, restore power to the appliance.
White-Rodgers 3F01-110 Snap Disc Fan Control held in a hand for size comparison

شکل 3: The White-Rodgers 3F01-110 Snap Disc Fan Control held in a hand, illustrating its compact size and dimensions (approximately 1.4 inches / 3 cm in height).

4. عملیاتي لارښوونې

The White-Rodgers 3F01-110 Snap Disc Fan Control operates automatically based on the ambient temperature at its mounting location.

  • Fan Activation (Cut-In): When the temperature at the control's location rises to 110°F (43°C), the internal snap disc will close the electrical contacts, activating the connected fan or blower.
  • Fan Deactivation (Cut-Out): When the temperature at the control's location drops to 90°F (32°C), the internal snap disc will open the electrical contacts, deactivating the connected fan or blower.
  • This automatic operation ensures that the fan runs only when necessary to circulate heated or cooled air, optimizing system efficiency.

5. ساتنه

The White-Rodgers 3F01-110 Snap Disc Fan Control is designed for reliable, long-term operation with minimal maintenance. However, periodic inspection is recommended.

  • کلنۍ معاینه: Annually, or as part of routine HVAC system maintenance, inspect the control for any signs of physical damage, corrosion, or loose wiring connections.
  • پاکول: Ensure the metallic disc and surrounding area are free from dust, debris, or obstructions that could impede proper temperature sensing. Use a soft, dry cloth for cleaning. Do not use liquids or abrasive cleaners.
  • بدلول: If the control shows signs of malfunction, inconsistent operation, or physical damage, it should be replaced by a qualified technician.

6. ستونزه حل کول

If you experience issues with your fan or blower system, consider the following troubleshooting steps related to the snap disc control.

6.1 Fan Does Not Turn On

  • ځواک چیک کړئ: Ensure the appliance has power and the fan motor is operational.
  • د تودوخې معاینه: Verify that the temperature at the control's location has reached or exceeded 110°F (43°C).
  • تارونه: Inspect wiring connections for looseness or damage.
  • Control Failure: If the temperature is above the cut-in point and the fan still does not activate, the control may be faulty and require replacement.

6.2 Fan Does Not Turn Off

  • د تودوخې معاینه: Verify that the temperature at the control's location has dropped below 90°F (32°C).
  • Control Failure: If the temperature is below the cut-out point and the fan continues to run, the control's contacts may be stuck closed, indicating a faulty unit that requires replacement.

7. مشخصات

مشخصاتتفصیل
د ماډل شمیره3F01-110
برانډEmerson (White-Rodgers)
د اړیکو ډولپه نورمال ډول خلاص (SPST)
Cut-In Temperature110°F (43°C)
Cut-Out Temperature90°F (32°C)
والیtage120 وولټ (AC)
د ترمینل ډولسکرو
د نصب کولو ډولFlanged Airstream Mount (3/4" snap disc compatible)
د موادو ډولPlastic (base)
د توکي ابعاد (L x W x H)1 x 5 x 8.25 انچه
د توکي وزن0.7 اونس
UPC786710001697

8. تضمین او ملاتړ

For warranty information or technical support regarding the White-Rodgers 3F01-110 Snap Disc Fan Control, please refer to the official Emerson or White-Rodgers webسایټ ته لاړ شئ یا مستقیم د دوی د پیرودونکو خدماتو سره اړیکه ونیسئ. د تضمین ادعاوو لپاره خپل د پیرود رسید وساتئ.

Emerson Customer Support: د مرستې لپاره، لیدنه وکړئ Emerson Contact Us page or consult your product packaging for specific support details.

اړوند اسناد - 3F01-110

مخکېview د ایمرسن بلو بې سیم آرامۍ انٹرفیس 1F98EZ-1621 د کور مالک کارونکي لارښود
د ایمرسن بلو بېسیم کمفرټ انٹرفیس لپاره د کارونکي لارښود، ماډل 1F98EZ-1621. دا لارښود د ترموسټاټ د تنظیم، پروګرام کولو، عملیاتو او ساتنې په اړه لارښوونې چمتو کوي.
مخکېview د خپل ایمرسن ترموسټاټ ماډل نمبر څنګه ومومئ
ستاسو د ایمرسن ترموسټاټ، په ځانګړې توګه د 1F95EZ-0671 ماډل کې د ماډل نمبر موندلو لپاره لارښود. زده کړئ چې څنګه د مخکینۍ پوښ لرې کړئ او د وسیلې په شا کې د ماډل نمبر وپیژنئ.
مخکېview د ایمرسن بلیو ترموسټاټ 1F98EZ-1421/1F98EZ-1441 د کور مالک کارونکي لارښود
د ایمرسن بلو ترموسټاټ ماډلونو 1F98EZ-1421 او 1F98EZ-1441 لپاره د کور مالکینو جامع لارښود، د تنظیم، پروګرام کولو، سیسټم عملیات، تشخیص او ساتنې توضیحات.
مخکېview 1F75C-11PR د پروګرام وړ ترموسټاټ نصب او عملیاتي لارښوونې
د ایمرسن 1F75C-11PR پروګرام وړ ترموسټاټ لپاره جامع نصب او عملیاتي لارښوونې. د تارونو، د نصب کونکي مینو ترتیبات، د ترموسټاټ عملیات، پروګرام کول، او د ستونزو حل کول پوښي.
مخکېview د ایمرسن 1F75C-11NP ترموسټاټ نصبولو او عملیاتو لارښود
د ایمرسن 1F75C-11NP ترموسټاټ نصب او چلولو لپاره جامع لارښود، د غوره HVAC سیسټم فعالیت لپاره د تارونو، ترتیب، او ستونزو حل پوښښ کوي.
مخکېview د ایمرسن 1F83C-11NP ترموسټاټ نصب او عملیاتي لارښود
د ایمرسن 1F83C-11NP واحدونو نصب او چلولو لپاره جامع لارښودtage ترموسټاټ. د تارونو، نصب کونکو او کاروونکو مینو، د ستونزو حل کول، او مشخصات پوښي.