The Altronix ACM8 Access Power Controller is designed to manage power distribution for access control systems. This unit features eight individually fused trigger outputs, providing reliable power and protection for various access control devices. It is suitable for a range of applications requiring controlled power distribution.
2. محصول ختم شوview
The ACM8 is a versatile power distribution board, ideal for integrating with access control panels. It provides individually fused outputs, ensuring protection for connected devices. The board is constructed from durable phenolic or fiberglass material and is UL Recognized, meeting UL294 standards for access control system units.

شکل ۱: پورته څخه ښکته view of the Altronix ACM8 Access Power Controller board, showing the eight fused outputs, relays, and terminal blocks.

شکل ۳: زاویه لرونکی view of the Altronix ACM8 Access Power Controller, highlighting the compact design and component layout.
3. ځانګړتیاوې
- Eight individually fused outputs for device protection.
- ننوتۍ جلدtage: 12 to 24 Volt AC or DC.
- د محصول Voltage: 12 to 24 Volt AC or DC.
- UL Recognized and UL294 compliant for access control applications.
- Constructed from durable Phenolic or Fiberglass material.
- د اسانه ادغام لپاره کمپیکټ ابعاد.
4. مشخصات
| مشخصات | تفصیل |
|---|---|
| د ماډل شمیره | ACM8 |
| د محصول ابعاد (L x W x H) | 8 x 4.5 x 1.25 انچه |
| ننوتۍ جلدtage | له ۱۲ څخه تر ۲۴ ولټه AC یا DC پورې |
| د محصول Voltage | له ۱۲ څخه تر ۲۴ ولټه AC یا DC پورې |
| د محصولاتو شمیر | 8 (Fused) |
| مواد | فینولیک یا فایبر ګلاس |
| معیارونه | UL پیژندل شوی، UL294 |
| د توکي وزن | 11.2 اونس |
| جوړونکی | ALTRONIX |
5. ترتیب کول
- د واحد نصبول: Securely mount the ACM8 board in a suitable enclosure or panel using appropriate hardware. Ensure adequate ventilation if enclosed.
- د بریښنا پیوستون: Connect the main power source (12-24V AC or DC) to the designated input terminals. Observe correct polarity when using a DC input. Refer to the board markings for positive (+) and negative (-) terminals.
- وتۍ اړیکې: Connect your access control devices (e.g., locks, readers) to the individually fused output terminals. Each output provides power when triggered. Ensure proper wiring for each connected device according to its specifications.
- د محرک داخلول: Connect the trigger input from your access control panel or other control device to the ACM8's trigger terminals. This signal will activate the corresponding output.
- ځمکني کول: ډاډ ترلاسه کړئ چې واحد د ځایی بریښنایی کوډونو او خوندیتوب معیارونو سره سم په سمه توګه ځای پر ځای شوی دی.
6. عملیاتي لارښوونې
- ځواک پورته کول: Once all connections are secure and verified, apply power to the ACM8 unit.
- د LED شاخصونه: Each output has an associated LED indicator. When an output is active and power is flowing correctly through its fuse, the corresponding LED will illuminate.
- Trigger Functionality: When a trigger signal is received at the input, the ACM8 will activate the designated output, providing power to the connected access control device.
- Fuse Monitoring: The LED indicators also serve as a visual check for fuse integrity. If an LED is off when the output should be active, it indicates a potential blown fuse or a wiring issue to the connected device.
7. ساتنه
- منظم معاینه: په دوره یي ډول د ټولو تارونو اتصالونه معاینه کړئ ترڅو ډاډ ترلاسه شي چې دوی خوندي دي او د زنګ یا زیان څخه پاک دي.
- د فیوز بدلول: If an output fuse blows, always replace it with a fuse of the same type and rating (e.g., 250V, 2A). Using an incorrect fuse can damage the unit or connected devices.
- پاکول: Keep the unit free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
- د چاپیریال شرایط: Ensure the operating environment remains within specified temperature and humidity ranges to prevent malfunction.
8. ستونزه حل کول
- No Power to Any Outputs:
- Verify that the main input power supply is active and correctly connected to the ACM8.
- Check the main fuse (if applicable to your power supply) and ensure it is intact.
- Individual Output Failure (LED off when active):
- Check the specific output fuse for the affected channel. Replace if blown.
- Verify the wiring to the connected device for shorts or disconnections.
- Ensure the trigger signal for that specific output is being received correctly.
- موقتي عملیات:
- Inspect all terminal connections for looseness.
- د حجم لپاره وګورئtage fluctuations from the input power supply.