1. محصول ختم شوview
The Cooper Lighting Sure-Lites® EU Series EUR70R is a self-powered, LED edge-lit exit sign designed for recessed mounting. It features a red 'EXIT' legend and operates on 120/277 Volts AC. This unit provides reliable emergency illumination for egress pathways.
کلیدي ځانګړتیاوې عبارت دي له:
- Self-powered operation with an internal sealed lead calcium battery.
- Energy-efficient LED illumination.
- Anodized aluminum construction for durability.
- Recessed mounting for a clean aesthetic.
- Solid state, voltage limited charger.
- ټیټ ولtage disconnect to protect the battery.
2. د خوندیتوب معلومات
WARNING: Risk of electric shock. Disconnect power before installation or servicing.
- All electrical connections must be made in accordance with local codes, ordinances, and the National Electric Code (NEC).
- نصب کول باید د وړ پرسونل لخوا ترسره شي.
- د عرضې حجم ډاډمن کړئtage is compatible with the fixture (120/277V AC).
- د ګازو یا برقی هیټرونو سره نږدې مه کیږدئ.
- د برېښنا رسونې تارونو ته اجازه مه ورکوئ چې ټوټه ټوټه شي یا زیانمن شي.
- The battery is an integral component and is not user-replaceable.
3. د بسته محتويات
د نصبولو پیل کولو دمخه ډاډ ترلاسه کړئ چې ټولې برخې شتون لري:
- EUR70R LED Edge-Lit Exit Sign unit
- Die-cast canopy (for mounting)
- Installation hardware (screws, wire nuts, etc. - may vary)
- د لارښوونې پاڼه (دا سند)
۵. نصب کول (تنظیم)
This exit sign is designed for recessed mounting. Follow these steps for proper installation:
- د نصب کولو ځای چمتو کړئ: Ensure the ceiling or wall opening is appropriately sized for recessed installation. The product dimensions are approximately 14.25 inches (L) x 12.88 inches (W) x 0.4 inches (D). Ensure there is sufficient depth and clearance for the fixture and wiring.
- د بریښنا قطع کول: Turn off the electrical power at the circuit breaker or fuse box before proceeding.
- د تارونو نښلول:
- Connect the building's AC supply wires to the corresponding wires on the exit sign.
- The unit is designed for 120V or 277V AC input. Connect the appropriate voltage wires as per the wiring diagram provided with the unit (refer to specific wiring labels on the fixture).
- Ensure all connections are secure using approved wire connectors.
- د ځمکې تار سره وصل کړئ.
- د فکسچر نصب کول:
- Carefully insert the exit sign into the prepared recessed opening.
- Secure the fixture using the provided mounting hardware and die-cast canopy, ensuring it is flush and stable.
- Initial Power-Up and Battery Charge:
- Restore AC power to the circuit.
- The unit's internal battery will begin charging. Allow at least 24 hours for the battery to achieve a full charge before conducting any discharge tests.
- Observe the charging indicator light (if present) to confirm proper operation.

Figure 1: Cooper Lighting EUR70R LED Edge-Lit Exit Sign. This image shows the front view of the exit sign with the red 'EXIT' legend, indicating its sleek, recessed design.
5. عملیات
The EUR70R exit sign operates automatically:
- AC Power Present: When normal AC power is supplied, the LED 'EXIT' legend will be illuminated, and the internal battery will be charged and maintained by the solid-state charger.
- AC Power Failure: In the event of an AC power interruption, the unit will automatically switch to battery power, illuminating the 'EXIT' legend for a minimum duration as required by safety codes. The low-voltage disconnect feature prevents deep discharge of the battery.
- AC Power Restored: When AC power is restored, the unit will automatically switch back to AC operation, and the battery will begin recharging.
6. ساتنه
Regular maintenance ensures the reliable operation of your exit sign.
- میاشتنۍ ازموینه: Press and hold the test button (if present) for 30 seconds. The 'EXIT' legend should remain illuminated. Release the button; the legend should return to normal operation.
- کلنۍ ازموینه: Disconnect AC power to the unit for 90 minutes. The 'EXIT' legend should remain illuminated for the entire duration. Reconnect AC power after the test.
- پاکول: Clean the sign's surface with a soft, damp ټوکر د کثافاتو پاکوونکي یا محلول مه کاروئ.
- د بیټرۍ بدلول: The sealed lead calcium battery has a typical lifespan. If the unit fails to meet the required emergency illumination duration during testing, the battery may need replacement. This should be performed by qualified service personnel.
7. ستونزه حل کول
| ستونزه | احتمالي لامل | د حل لاره |
|---|---|---|
| 'EXIT' legend does not illuminate on AC power. | No AC power to the unit. د تارونو ناسمه اړیکه. د LED ناکامي. | سرکټ بریکر/فیوز چیک کړئ. د تارونو اړیکې تایید کړئ. د وړ خدماتو کارمندانو سره اړیکه ونیسئ. |
| 'EXIT' legend does not illuminate during power failure or test. | بیټرۍ چارج شوې نه ده. د بیټرۍ ناکامي. د داخلي سرکټ تېروتنه. | Allow 24 hours for initial charge. Perform annual test; if failure persists, battery may need replacement by qualified personnel. د وړ خدماتو کارمندانو سره اړیکه ونیسئ. |
| Unit does not stay illuminated for required duration during test. | بیټرۍ په بشپړه توګه چارج شوې نه ده. د بیټرۍ ژوند پای ته نږدې دی. | Ensure unit has been on AC power for at least 24 hours. بیټرۍ ممکن د وړ پرسونل لخوا بدلولو ته اړتیا ولري. |
8. مشخصات
- ماډل: EUR70R
- نښه: Cooper Lighting Sure-Lites®
- ننوتۍ جلدtage: ۱۲۰/۲۴۰ ولټه AC
- Power Rating (AC): ۶۵۰ واټونه (۷۰ وولټ)، ۷۸۰ واټونه (۱۰۰ وولټ)
- د رڼا سرچینه: LED
- Legend Color: Red 'EXIT'
- د نصب کولو ډول: بیاځل شوی
- ساختماني مواد: Anodized المونیم
- ابعاد: 14.25 انچه (L) x 12.88 انچه (W) x 0.4 انچه (D)
- وزن: تقریبا 2 پونډه
- د بیټرۍ ډول: Sealed Lead Calcium (internal, non-user replaceable)
- ASIN: B018HR72YY
- UPC: 993520725594
9. تضمین او ملاتړ
For warranty information or technical support, please contact Cooper Lighting customer service. Retain your proof of purchase for warranty claims. Specific warranty terms and conditions may vary and are typically provided at the time of purchase or on the manufacturer's official webسایټ
جوړونکی: د کوپر رڼا