Yaskawa CIMR-7.5G2

Yaskawa CIMR-7.5G2 Variable Frequency Drive User Manual

Model: CIMR-7.5G2 | Brand: Yaskawa

1. پیژندنه او وروستهview

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Yaskawa CIMR-7.5G2 Variable Frequency Drive (VFD). The CIMR-7.5G2 is a robust industrial drive designed for precise speed control of three-phase AC induction motors, operating on a 200-220V, 50-60 Hz, 3-phase power supply. It is crucial to read and understand this manual completely before attempting any installation, operation, or maintenance procedures.

Yaskawa CIMR-7.5G2 Variable Frequency Drive with top cover open, revealing internal components and wiring terminals.

Figure 1: Yaskawa CIMR-7.5G2 Variable Frequency Drive with top cover open, revealing internal components and wiring terminals.

2. د خوندیتوب معلومات

خبرداری: د بریښنایی شاک خطر

  • Only qualified and trained personnel should install, operate, or maintain this equipment.
  • Always disconnect all power sources to the drive and wait for the charge indicator to extinguish before performing any work on the drive or connected equipment. Residual voltage may be present even after power is disconnected.
  • Ensure proper grounding of the drive and motor to prevent electrical shock.
  • Do not operate the drive with covers removed.
  • Protect the drive from moisture, dust, and corrosive gases.

احتیاط: د سامان زیان

  • Do not connect the AC power supply to the output terminals (U, V, W).
  • Ensure correct wiring and proper terminal connections.
  • تایید کړئ چې د ننوتلو حجمtage matches the drive's specifications (200-220V, 3-phase).

3. ترتیب کول

3.1 پیک کول او تفتیش کول

Carefully unpack the CIMR-7.5G2 drive. Inspect the unit for any signs of physical damage that may have occurred during shipping. If any damage is found, contact your supplier immediately.

3.2 پورته کول

Mount the drive vertically on a flat, stable, and non-flammable surface. Ensure adequate clearance around the drive for proper ventilation and heat dissipation. Refer to the drive's dimensions for specific spacing requirements. Avoid mounting in direct sunlight or areas with excessive vibration.

3.3 تارونه

All wiring must comply with local and national electrical codes. Use appropriate wire gauges for the power and motor connections.

  1. Grounding (E): Connect the ground terminal of the drive to a reliable earth ground. This is critical for safety.
  2. Input Power (R, S, T): Connect the 200-220V, 3-phase AC power supply to the R, S, and T input terminals. Ensure the phase sequence is correct.
  3. د موټرو محصول (U، V، W): Connect the three-phase motor leads to the U, V, and W output terminals of the drive.
  4. د کنټرول تارونه: Connect any necessary control signals (e.g., start/stop commands, speed reference, fault outputs) to the designated control terminals. Refer to the terminal diagram on the drive for specific connections.
Yaskawa CIMR-7.5G2 Variable Frequency Drive showing wiring terminals for input power, motor output, and ground.

Figure 2: Yaskawa CIMR-7.5G2 wiring terminals for power and motor connections.

4. عملیاتي لارښوونې

4.1 د کنټرول پینلview

The CIMR-7.5G2 features a user-friendly control panel with a digital display and several function buttons for operation and parameter setting.

تړل view of the Yaskawa CIMR-7.5G2 control panel and wiring terminals, showing the digital display and operational buttons.

3 شکل: تړل view of the Yaskawa CIMR-7.5G2 control panel.

  • ډیجیټل ډیزاین: Shows operational status, frequency, current, voltage, and parameter values.
  • MODE/DATA Button: Used to switch between display modes and enter/confirm parameter settings.
  • د چلولو تڼۍ: د موټرو عملیات پیل کوي.
  • د ودرولو/بیا تنظیمولو تڼۍ: Stops motor operation and resets fault conditions.
  • پورته/ښکته تیرونه: Used to navigate through parameters and adjust values.

4.2 بنسټیز عملیات

  1. پاور آن: Apply 3-phase power to the drive. The display will illuminate.
  2. د موټرو پیل: فشار ورکړئ چلول button. The motor will accelerate to the set speed.
  3. موټر ودروئ: فشار ورکړئ ودروئ/بیا تنظیم کړئ تڼۍ. موټور به ورو شي او ودریږي.
  4. سرعت تنظیم کړئ: د کارولو پورته / ښکته تیرونه to adjust the output frequency (motor speed) while the drive is running or in standby, depending on the parameter settings.

4.3 د پیرامیټر ترتیبات

The CIMR-7.5G2 has various parameters that can be configured to customize its operation for specific applications. These include acceleration/deceleration times, maximum/minimum frequencies, motor data, and control modes. Refer to the detailed parameter list in the complete Yaskawa CIMR-7.5G2 technical manual for comprehensive information on each parameter and its function.

5. ساتنه

Regular maintenance is essential to ensure the long-term reliability and performance of your Yaskawa CIMR-7.5G2 drive.

  • د دوړو لرې کول: Periodically clean dust and debris from the drive's heatsink and ventilation openings using compressed air. Ensure power is disconnected before cleaning.
  • د ټرمینل تفتیش: Check all wiring terminals for tightness and signs of corrosion. Loose connections can lead to overheating and drive malfunction.
  • د یخولو فین: Inspect the cooling fan for proper operation and signs of wear. Replace if necessary.
  • د چاپیریال شرایط: ډاډ ترلاسه کړئ چې عملیاتي چاپیریال د ټاکل شوي تودوخې او رطوبت حدودو کې پاتې کیږي.

6. ستونزه حل کول

This section provides general guidance for common issues. For detailed troubleshooting and error code explanations, refer to the comprehensive Yaskawa CIMR-7.5G2 technical manual.

ستونزهاحتمالي لاملد حل لاره
ډرایو نه چالانېږيد ننوتلو ځواک نشته؛ فلج شوی فیوز؛ داخلي خرابيCheck power supply; Inspect fuses; Contact Yaskawa support.
موټروان نه چلیږيIncorrect wiring; Drive in fault state; No run commandVerify wiring; Check display for fault codes and reset; Ensure run command is active.
overcurrent تېروتنهMotor overload; Short circuit in motor/wiring; Rapid accelerationCheck motor load; Inspect motor/wiring; Increase acceleration time.
اوورولtage ګناهلوړ انټرنیټ ولtage؛ چټک کمښت؛ بیا تولیدونکی بارد ننوتلو حجم چیک کړئtage; Increase deceleration time; Consider braking resistor.

If you encounter persistent issues or error codes not listed here, please contact Yaskawa technical support.

7. مشخصات

Key technical specifications for the Yaskawa CIMR-7.5G2 Variable Frequency Drive:

  • د ماډل شمیره: CIMR-7.5G2
  • ننوتۍ جلدtage: 200-220V AC, 3-Phase
  • د ننوتۍ فریکونسۍ: 50-60 Hz
  • جوړونکی: یاکاوا
  • د توکي وزن: 15 پونډه
  • ASIN: B01MQ237XQ
  • د شتون لومړۍ نیټه: د اکتوبر ۲۹، ۲۰۲۳

8. تضمین او ملاتړ

For information regarding the warranty terms and conditions for your Yaskawa CIMR-7.5G2 drive, please refer to the documentation provided at the time of purchase or visit the official Yaskawa website. For technical assistance, troubleshooting beyond this manual, or spare parts inquiries, please contact Yaskawa customer support directly. Ensure you have your model number (CIMR-7.5G2) and serial number ready when contacting support.

You can find more information and support resources on the official Yaskawa webسایټ: www.yaskawa.com

اړوند اسناد - CIMR-7.5G2

مخکېview YASKAWA AC Drive L1000A: Quick Start Guide for Elevator Applications
This Yaskawa AC Drive L1000A Quick Start Guide provides essential information for the safe and effective installation, wiring, and initial setup of AC drives for elevator applications. It covers critical safety precautions, mechanical and electrical installation, keypad operation, and startup procedures.
مخکېview YASKAWA AC Drive A1000 Quick Start Guide
Quick Start Guide for the YASKAWA AC Drive A1000 series, a high-performance vector control drive. This manual provides essential information for safe installation, wiring, initial setup, operation, and troubleshooting of industrial AC drives.
مخکېview Yaskawa V7 & V74X Drives Modbus Communication Manual
Guide to Modbus communication for Yaskawa V7 and V74X AC drives, covering network setup (RS-232, RS-422, RS-485), parameter access, message formats, and troubleshooting for industrial automation.
مخکېview Yaskawa Z1000 AC Drive User Manual for HVAC Fan and Pump Applications
This comprehensive user manual provides detailed instructions for the Yaskawa Z1000 AC Drive, covering installation, setup, programming, operation, and troubleshooting for HVAC fan and pump applications. It includes specifications for 200V and 400V classes.
مخکېview Yaskawa AC Drive - A1000 High Frequency Custom Software Supplement
This document supplements the Yaskawa A1000 Quick Start Guide and Technical Manual, detailing modifications and new functions for the High Frequency Custom Software. It covers changes to parameters, functions, and application notes for high-speed motor applications.
مخکېview YASKAWA AC Drive GA700 Initial Steps - Installation and Operation Guide
Comprehensive guide for the YASKAWA AC Drive GA700, covering essential initial steps for installation, wiring, operation, and safety. This document details product features, user qualifications, safety warnings, moving and receiving procedures, keypad functions, LED status indicators, and a step-by-step start-up guide for high-performance industrial applications.