This manual provides detailed instructions for the proper setup, operation, and maintenance of your DAC Patient Alert & Personal Alarm, Model HCA001. This device is designed to serve two primary functions: to alert caregivers when a patient moves from a bed or chair, and to function as a personal security alarm for immediate protection.
Please read these instructions carefully before using the device to ensure safe and effective operation.

Image 1: The DAC Patient Alert & Personal Alarm, Model HCA001, shown in its original retail packaging. The packaging highlights its multi-purpose functionality as both a patient alert and a personal alarm.
2. د خوندیتوب معلومات
- د بیټرۍ خوندیتوب: Always use the specified 17-volt battery. Do not mix old and new batteries, or different types of batteries. Dispose of used batteries responsibly according to local regulations.
- د ساه بندیدو خطر: Keep small parts, such as the battery and clips, out of reach of children and individuals who may ingest them.
- د الارم حجم: The alarm produces a loud 110dB sound. Avoid prolonged exposure to the alarm at close range to prevent potential hearing discomfort.
- مطلوب استعمال: This device is an alert system and not a substitute for direct supervision or professional medical care.
- د اوبو ښکاره کول: The device is not waterproof. Avoid exposure to water or excessive moisture.
3. د بسته محتويات
مهرباني وکړئ تصدیق کړئ چې ټول توکي ستاسو په کڅوړه کې شتون لري:
- DAC Patient Alert & Personal Alarm Unit (HCA001)
- 48-inch Adjustable Cord with Alligator Clip and Snap Clip
- 8-inch Accessory Strap with Buckle
- Alarm Mount with Clip or Double-Sided Tape (pre-attached or separate)
Note: A 17-volt battery is required and is not included in the package.
4. ترتیب کول
4.1 د بیټرۍ نصب کول
- د الارم واحد په شا کې د بیټرۍ کڅوړه ومومئ.
- د بیټرۍ کمپارټ پوښ په احتیاط سره خلاص کړئ.
- Insert one 17-volt battery, ensuring the polarity (+/-) matches the indicators inside the compartment.
- د بیټرۍ کمپارټ پوښ په خوندي ډول وتړئ.

Image 2: The back of the DAC Patient Alert & Personal Alarm packaging, illustrating details such as battery requirements (17 Volt Battery Required, Not Included) and warranty information.
4.2 د نصبولو اختیارونه
The alarm unit offers several versatile mounting options:
- مربوط کلیپ: The alarm unit features a built-in clip on its back, allowing it to be easily attached to clothing, a belt, or other thin edges.
- دوه اړخیزه ټیپ: For more permanent placement on flat surfaces like walls, bed frames, or furniture, use the provided double-sided tape on the alarm mount. Ensure the surface is clean and dry before application.
- Accessory Strap: The 8-inch accessory strap with a buckle can be used to secure the alarm to larger objects or limbs, providing a flexible attachment solution.
5. عملیاتي لارښوونې
5.1 Patient Alert Mode
This mode is designed to alert caregivers when a patient moves or attempts to exit a bed or chair.
- Attach the Cord: Securely attach the 48-inch adjustable cord to the patient's clothing or a bedsheet using the alligator clip or snap clip.
- Connect to Alarm: Insert the other end of the cord (the pin) into the designated jack on the alarm unit.
- Position the Alarm: Place the alarm unit in a location where the caregiver can easily hear it, such as near the bed, chair, or on a bedside table. Ensure the cord has enough slack for comfortable patient movement but will pull out if the patient attempts to leave the monitored area.
- فعالول: When the patient moves sufficiently to pull the cord's pin out of the alarm unit, the 110dB alarm will sound.
- د الارم بیا تنظیم کول: To silence the alarm, re-insert the pin firmly into the alarm unit's jack.
5.2 Personal Alarm Mode
This mode provides a loud alarm for personal protection in emergency situations.
- Carry the Alarm: Keep the alarm unit readily accessible, for example, clipped to your belt, bag, or held in your hand.
- فعالول: In an emergency, pull the cord's pin completely out of the alarm unit. The 110dB alarm will sound immediately.
- د الارم بیا تنظیم کول: To silence the alarm, re-insert the pin firmly into the alarm unit's jack.
6. ساتنه
6.1 پاکول
To clean the alarm unit, wipe it with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the unit in water.
6.2 د بیټرۍ بدلول
When the alarm sound becomes weak or fails to activate, it is time to replace the 17-volt battery. Follow the battery installation steps outlined in Section 4.1.
7. ستونزه حل کول
- الارم نه غږېږي:
- Check if the 17-volt battery is installed correctly and is not depleted. Replace if necessary.
- Ensure the pin is fully removed from the jack when attempting to activate the alarm.
- Alarm sounds weakly:
- The battery may be low. Replace the 17-volt battery.
- False alarms in Patient Alert Mode:
- Ensure the cord is securely attached to the patient's clothing and the alarm unit.
- Adjust the cord length to provide sufficient slack for normal movement without accidental dislodgement.
8. مشخصات
- ماډل: HCA001
- د بریښنا سرچینه: 1 x 17-volt battery (not included)
- د الارم حجم: 110 dB
- د تار اوږدوالی: ۳۵.۴۳ انچه (د تنظیم وړ)
- Accessory Strap Length: 8 انچه
- دندې: Patient Alert, Personal Protection Alarm
9. د تضمین معلومات
This DAC Patient Alert & Personal Alarm (Model HCA001) is guaranteed against defects in materials and workmanship in normal use for a period of شپږ (۶) میاشتې from the date of purchase. This warranty is valid only if the alarm has not been altered or modified, or if a repair attempt has not been made by unauthorized personnel.
مهرباني وکړئ د تضمین ادعاګانو لپاره د پیرود ثبوت وساتئ.
۹. اړیکه او ملاتړ
For technical assistance, warranty claims, or further inquiries, please contact:
DAC Technologies of America Inc
د پیرودونکي ملاتړ: 1-800-216-1515