پیژندنه
This manual provides essential information for the proper installation and use of the Penn-Union BLU1/0S19 Copper Compression Lug. This lug is designed for reliable electrical connections, featuring a standard barrel, a single stud hole, and an inspection window. Adherence to these instructions is crucial for ensuring safe and effective performance.
د خوندیتوب معلومات
WARNING: Electrical shock hazard. Always disconnect power before installing or servicing electrical components. Only qualified personnel should perform electrical installations.
- Ensure all power sources are de-energized and locked out before beginning work.
- د مناسب شخصي محافظتي تجهیزاتو (PPE) څخه کار واخلئ، په شمول د موصل شوي دستکشو او د سترګو محافظت.
- Verify the lug's compatibility with the conductor material (copper) and gauge (1/0 AWG).
- Use only recommended crimping tools and dies for proper installation.
- Inspect the lug and conductor for damage before installation.
محصول پای ته ورسیدview
The Penn-Union BLU1/0S19 is a high-quality copper compression lug designed for secure electrical terminations. Key features include:
- معیاري بیرل: برابروي ample space for conductor insertion and crimping.
- Inspection Window: Allows visual verification of full conductor insertion before crimping.
- Single Hole Tongue: Designed for connection to a 1/4" stud.
- مواد: Constructed from durable copper for excellent conductivity.

Figure 1: Penn-Union BLU1/0S19 Copper Compression Lug. This image shows the metallic lug with a cylindrical barrel on one end and a flat tongue with a single hole on the other. The barrel has an inspection window, and the tongue is designed for a stud connection.
تنظیم او نصب کول
Follow these steps for proper installation of the compression lug:
- Prepare the Conductor: Strip the insulation from the 1/0 AWG copper conductor to the length specified by the lug manufacturer or crimping tool instructions. Ensure the conductor strands are clean and free of oxidation.
- کنډکټر داخل کړئ: Insert the stripped conductor fully into the lug barrel. The conductor should be visible through the inspection window, indicating full insertion.
- Crimp the Lug: Using a crimping tool with the correct die for 1/0 AWG copper lugs, perform the required number of crimps according to the tool manufacturer's instructions. Ensure each crimp is complete and secure.
- کرمپ معاینه کړئ: Visually inspect the crimped area for proper deformation and ensure the conductor is still visible in the inspection window. The crimp should be uniform and tight.
- Connect to Stud: Place the lug's tongue onto the 1/4" stud. Secure it with appropriate hardware (e.g., washer, nut) and torque to the recommended specification for the stud size to ensure a secure electrical and mechanical connection.
عملیاتي اصول
Once properly installed, the Penn-Union BLU1/0S19 compression lug provides a low-resistance, high-integrity electrical connection between the 1/0 AWG copper conductor and the 1/4" stud. The crimped connection ensures optimal current flow and mechanical strength, while the copper material offers excellent conductivity and corrosion resistance in typical environments.
ساتنه
Compression lugs generally require minimal maintenance after proper installation. However, periodic inspection is recommended, especially in critical applications or harsh environments.
- بصری معاینه: Check for signs of corrosion, discoloration (indicating overheating), or mechanical damage to the lug or conductor insulation.
- د اتصال بشپړتیا: Ensure the stud connection remains tight. Re-torque if necessary, following manufacturer's specifications.
- پاکول: If necessary, clean the lug and connection points using a non-abrasive, electrically safe cleaner.
د ستونزو حل کول
Most issues with compression lugs stem from improper installation. If a connection fails or shows signs of overheating, consider the following:
- لوز پیوستون: If the lug is loose on the stud, re-torque the nut to the specified value. A loose connection can cause resistance and heat buildup.
- Improper Crimp: If the crimp is not uniform, too shallow, or too deep, it can lead to high resistance. The lug should be replaced and re-crimped with the correct tool and die. Ensure the conductor was fully inserted.
- Incorrect Wire Gauge or Material: Verify that the 1/0 AWG copper conductor matches the lug's specifications. Using an incorrect gauge or aluminum wire with a copper lug can lead to poor connections and failure.
- زنګ وهل: In corrosive environments, ensure proper environmental sealing or use lugs designed for such conditions. Clean and protect connections as needed.
مشخصات
| صفت | ارزښت |
|---|---|
| برانډ | Penn-Union |
| د ماډل شمیره | BLU1 0S19 |
| د تماس مواد | مسو |
| ګیج | 1/0 AWG |
| د مطالعې اندازه | ۳/۴" |
| رنګ | Pink (Indicates 1/0 AWG for some manufacturers) |
| د توکي وزن | 10.08 ounces (for package quantity 10) |
تضمین او ملاتړ
For specific warranty information and technical support regarding the Penn-Union BLU1/0S19 Copper Compression Lug, please contact Penn-Union directly or refer to their official webسایټ د تضمین ادعاګانو لپاره خپل د پیرود رسید وساتئ.
جوړونکی: Penn-Union
د لومړي شتون نیټه: د اګست ۷، ۲۰۲۴