Beckett BK171UL

Beckett BK171UL Condensate Pump with Safety Switch User Manual

Model: BK171UL

1. پیژندنه

This manual provides detailed instructions for the installation, operation, and maintenance of the Beckett BK171UL Condensate Pump. This pump is designed for automatic removal of condensate from HVAC equipment, including air conditioners, furnaces, boilers, dehumidifiers, and high-efficiency oil or gas-fired furnaces. It is suitable for condensate water temperatures up to 150°F and acidic condensate.

Beckett BK171UL Condensate Pump

Image 1.1: Beckett BK171UL Condensate Pump, front view.

2. د خوندیتوب معلومات

خبرداری: د بریښنا شاک خطر. د خدمت کولو دمخه بریښنا قطع کړئ.

  • د نصب او عملیاتو دمخه ټولې لارښوونې په دقت سره ولولئ.
  • ډاډ ترلاسه کړئ چې د بریښنا رسولو د پمپ حجم سره سمون لريtage (115V).
  • پمپ د خراب شوي تار یا پلګ سره مه چلوئ.
  • Do not immerse the pump in water.
  • This pump is designed for indoor use only.
  • د عملیاتو پرمهال لاسونه د حرکت کولو برخو څخه پاک وساتئ.
  • د ځایی بریښنایی کوډونو سره سم مناسب ځمکنی کول ډاډمن کړئ.
  • The pump is equipped with a safety switch. Ensure it is correctly wired to prevent overflow.

3. د بسته محتويات

د نصبولو پیل کولو دمخه ډاډ ترلاسه کړئ چې ټولې برخې شتون لري:

  • Beckett BK171UL Condensate Pump unit
  • 3/8" O.D. barbed check valve
  • Integrated 6-ft grounded power cord
  • د لارښود لارښود (دا سند)
چاودنه وشوه view of Beckett BK171UL Condensate Pump components

انځور ۳.۱: چاودنه وشوه view showing pump components including cover, check valve, motor, fan, automatic switches, lift-to-test tab, bullseye level, floats, impeller, multi-slot metal mount tabs, 6 ft. grounded power cord, and collection tank.

4. نصب او تنظیم کول

4.1 د پمپ نصبول

The pump features stainless steel multi-slot mounting tabs for secure installation. Ensure the pump is placed on a level surface. Use the integrated bullseye level on the lid to confirm proper horizontal alignment.

Beckett BK171UL Condensate Pump installation features

Image 4.1: Close-up of pump showing bullseye level, twist lock check valve, and lift-to-test tab for easy installation and maintenance.

4.2 Condensate Inlet Connections

The pump is equipped with four 1-1/8-inch diameter inlet holes for connecting condensate drain lines from your HVAC equipment. Connect the drain line(s) to any available inlet(s).

4.3 Discharge Line Connection

Connect a 3/8" I.D. vinyl tubing (not included) to the 3/8" O.D. barbed check valve. The check valve twists to lock into place on the pump, preventing backflow of discharged water. Route the discharge line to an appropriate drain, ensuring it has a continuous downward slope and is free from kinks or obstructions. The pump can lift water up to 17 feet vertically.

4.4 بریښنایی پیوستون

Plug the 6-ft grounded power cord into a standard 115V electrical outlet. Ensure the outlet is properly grounded and protected by a ground fault circuit interrupter (GFCI) if required by local codes.

4.5 Safety Switch Wiring

The integrated safety switch is designed to shut down the HVAC equipment or trigger an alarm in case of a pump malfunction or high water level, preventing overflow. Consult your HVAC equipment manual for proper wiring of the safety switch. Typically, the safety switch wires are connected in series with the low-voltage thermostat circuit of the HVAC unit.

5. عملیات

5.1 Automatic On/Off Operation

The Beckett BK171UL pump operates automatically. When condensate water in the collection tank reaches a predetermined level, the pump will activate, remove the water, and then shut off once the water level drops. This automatic cycle ensures efficient condensate removal without constant monitoring.

Beckett BK171UL Condensate Pump performance chart

Image 5.1: Diagram illustrating automatic ON/OFF operation and average performance at various lift heights (e.g., 95 GPH at 5 ft lift, 64 GPH at 10 ft lift, 17 ft shut-off).

5.2 Lift-to-Test Function

A "lift-to-test" tab is provided on the pump lid. Lifting this tab manually raises the float, simulating a high water level and activating the pump. This feature allows for quick testing of the pump's functionality and can also be used to drain the tank for servicing.

6. ساتنه

Regular maintenance ensures optimal performance and extends the life of your condensate pump.

  • میاشتنۍ معاینه: Visually inspect the pump, inlet, and discharge lines for any blockages, leaks, or damage. Ensure the discharge line is free of kinks.
  • Quarterly Cleaning:
    1. Disconnect power to the pump and the HVAC unit.
    2. Use the lift-to-test tab to drain the tank, or manually remove any remaining water.
    3. Carefully remove the pump cover.
    4. Clean the collection tank, floats, and impeller area to remove any sludge, debris, or mineral deposits. A mild detergent and soft brush can be used.
    5. Rinse all components thoroughly with clean water.
    6. Reassemble the pump, ensuring the cover is securely in place.
    7. Reconnect power and test the pump using the lift-to-test tab.
  • د تخلیې کرښه: Periodically check the discharge line for algae or mineral buildup, especially if the pump is handling acidic condensate. Clean or replace the tubing as necessary.

7. ستونزه حل کول

ستونزهاحتمالي لاملد حل لاره
پمپ نه چلیږيپمپ ته بریښنا نشتهCheck power cord connection, circuit breaker, and GFCI.
Float switch stuck or obstructedDisconnect power, remove cover, clean floats and tank.
Pump runs but does not discharge waterDischarge line clogged or kinkedInspect and clear the discharge line. Ensure no kinks.
Check valve obstructedDisconnect power, remove and clean the check valve.
امپیلر بند شویDisconnect power, remove cover, clean impeller area.
پمپ په دوامداره توګه پرمخ ځيFloat switch stuck in "on" positionDisconnect power, remove cover, clean floats and tank.
Leak in discharge line or check valveInspect all connections and the discharge line for leaks. Tighten or replace as needed.
پمپ شور دیDebris in impeller or motorDisconnect power, remove cover, clean impeller area.
Pump not levelAdjust pump placement using the bullseye level.

8. مشخصات

  • ماډل: BK171UL
  • والیtage: 115V
  • Maximum Lift: 17 فوټ
  • د جریان کچه: 112 GPH @ 1 ft lift
  • Ampزمانه: 1.1 Amps
  • واټtage: 60 واټ
  • فریکونسی: 60 HZ
  • د راټولولو ټانک ظرفیت: ۴ کوتره
  • د اخراج پیوستون: 3/8" O.D. barbed check valve
  • د ننوتلو اړیکې: Four 1-1/8" diameter holes
  • د بریښنا تار: 6 ft grounded with plug
  • Maximum Condensate Water Temperature: 150°F
  • مواد: Acrylonitrile Butadiene Styrene (ABS)، پلاستیک
  • ابعاد (L x W x H): ۸۳.۸" x ۵۵.۷" x ۴۴.۱"
  • د توکي وزن: 3.7 پونډه
  • د خوندیتوب ځانګړتیاوې: Integrated safety switch, Thermally protected motor
  • تصدیقونه: UL/cUL listed in U.S./Canada
Beckett BK171UL Condensate Pump dimensions

Image 8.1: Dimensions of the Beckett BK171UL Condensate Pump.

9. تضمین او ملاتړ

The Beckett BK171UL Condensate Pump comes with a د تولید کونکي 3 کلن تضمین. For warranty claims, technical assistance, or replacement parts, please contact Beckett Corporation customer support. Keep your purchase receipt as proof of purchase.

For further assistance, please refer to the official Beckett Corporation webسایټ یا د دوی د پیرودونکي خدماتو څانګې سره اړیکه ونیسئ.

اړوند اسناد - BK171UL

مخکېview د بیکټ CB22 اتوماتیک کنډنسیټ پمپ: نصب، عملیات او خوندیتوب لارښود
د بیکټ CB22 اتوماتیک کنډنسیټ واحد لپاره د مالکینو جامع لارښود. د نصبولو، خوندي عملیاتو، تارونو، ساتنې، ستونزو حل کولو، او محدود تضمین معلوماتو لپاره تفصيلي لارښوونې پکې شاملې دي.
مخکېview د بیکټ BK17/BK22 د کنډنسیټ لرې کولو پمپ نصبولو او ساتنې لارښود
دا لارښود د بیکټ BK17 او BK22 کنډنسیټ لرې کولو پمپونو لپاره مفصل نصب، ساتنه، او خوندیتوب لارښوونې چمتو کوي، پشمول د تضمین معلومات او د فعالیت مشخصات.
مخکېview Beckett Automatic Condensate Removal Pump Installation and Operation Manual
This manual provides comprehensive installation, operation, wiring, testing, and troubleshooting guidance for Beckett Automatic Condensate Removal Pumps, including models CL201UL, CL202UL, CL202ULHT, and CL202CE. It details warranty information and maintenance procedures.
مخکېview د بیکټ اکوا سمارټ ۷۶۰۰ بویلر کنټرول چټک حوالې لارښود
د بیکټ اکوا سمارټ ۷۶۰۰ لړۍ بویلر کنټرول لپاره یوه لنډه او چټکه لارښود، چې تخنیکي مشخصات، نصب، اساسي پروګرامینګ، او د تارونو ډیاګرامونه، د تضمین معلوماتو سره یوځای پوښي.
مخکېview د بیکټ اکوا سمارټ ماډل ۷۶۰۰ پرمختللي بویلر کنټرول نصب او عملیاتي لارښود
د بیکټ اکوا سمارټ ماډل ۷۶۰۰ بویلر کنټرول سیسټم لپاره جامع لارښود، چې نصب، تارونه، پروګرام کول، د هیټ مینیجر ™ په څیر ځانګړتیاوې، او د استوګنې او سپکو سوداګریزو غوښتنلیکونو لپاره د ستونزو حل کول پوښي.
مخکېview د بیکټ اکوا سمارټ ۷۶۱۰ بویلر کنټرول: د محصول پاڼه او مشخصات
د بیکټ اکوا سمارټ ۷۶۱۰ بویلر کنټرول لپاره جامع محصول پاڼه. د ځانګړتیاوو، ګټو، د هیټ مینیجر ™ فعالیت، اختیاري بېسیم بیا تنظیم، د امر کولو معلومات، د تارونو ډیاګرامونه، بریښنایی درجه بندي، د تودوخې مشخصات، او د چاپیریال درجه بندي توضیحات. د سینسرونو او لوازمو لپاره د برخې شمیرې شاملې دي.