1. پیژندنه
This user manual provides comprehensive instructions for the installation, configuration, operation, and maintenance of the Allied Telesis AT-GS950/18PS V2 Gigabit Ethernet Smart PoE+ Switch. This device is designed to provide reliable network connectivity and power delivery for various network devices.
مهرباني وکړئ د محصول کارولو دمخه دا لارښود په دقت سره ولولئ ترڅو د سم او خوندي عملیاتو ډاډ ترلاسه کړئ. دا لارښود د راتلونکي حوالې لپاره وساتئ.
2. محصول ختم شوview
The Allied Telesis AT-GS950/18PS V2 is a Gigabit Ethernet Smart PoE+ switch featuring IEEE 802.3at compliant PoE+ functionality. It simplifies network deployments by delivering both data and power over a single Ethernet cable, making it ideal for powering devices such as wireless LAN access points and IP cameras.
This switch also incorporates advanced intelligent features like VLAN support, Quality of Service (QoS), and Loop Detection Function (LDF). Management and maintenance are facilitated through an intuitive Web Graphical User Interface (GUI), accessible via a standard web براوزر

شکل 2.1: مخکی view of the Allied Telesis AT-GS950/18PS V2 switch, showing the 16 PoE+ Gigabit Ethernet ports, 2 SFP slots, and LED indicators for power, system status, and port activity.
3. ځانګړتیاوې
- ګیګابایټ ایترنیټ بندرونه: 16 x 10/100/1000BASE-T ports with PoE+ (Power over Ethernet Plus) capability.
- د SFP سلاټونه: 2 x SFP slots for fiber optic uplink connections.
- PoE+ Support (IEEE 802.3at): Provides up to 30W per port for compatible devices, simplifying power infrastructure.
- سمارټ ځانګړتیاوې: Includes VLAN (Virtual Local Area Network) for network segmentation, QoS (Quality of Service) for traffic prioritization, and LDF (Loop Detection Function) to prevent network loops.
- Web GUI Management: Easy configuration and monitoring through a user-friendly web-پر بنسټ انٹرفیس.
- بې فین ډیزاین: Ensures silent operation, suitable for office environments.
- د نصب وړ ریک: Includes a 19-inch rack mount kit for flexible installation.
4. د بسته محتويات
ډاډ ترلاسه کړئ چې ټول توکي شتون لري او په ښه حالت کې دي. که کوم شی ورک وي یا زیانمن شوی وي، سمدلاسه خپل پلورونکي سره اړیکه ونیسئ.
- Allied Telesis AT-GS950/18PS V2 Switch Unit
- Power Cable (AC100V compatible)
- Power Cable Retention Hook
- English Product Information Sheet
- Product Warranty Card (5 years)
- Serial Number Stickers (2 sheets)
- 19-inch Rack Mount Kit (1 set)
- Rubber Feet (4 pieces)
Note: The included power cable is for AC100V. If using AC200V, please consult with your installer.
5. ترتیب کول
5.1 فزیکي نصب کول
The AT-GS950/18PS V2 can be installed on a desktop or mounted in a standard 19-inch equipment rack.
- د ډیسټاپ نصب کول: Attach the provided rubber feet to the bottom of the switch to prevent slipping and ensure proper ventilation. Place the switch on a flat, stable surface.
- د ریک نصب کول: Use the included rack mount kit to secure the switch in a 19-inch equipment rack. Ensure adequate space for airflow around the unit.
Ensure the installation location is well-ventilated, free from excessive dust, and within the specified operating temperature and humidity ranges.
د شبکې اتصال
- Connect network devices (e.g., computers, servers, IP cameras, wireless access points) to the 10/100/1000BASE-T Ethernet ports (1-16) using standard Ethernet cables.
- For devices requiring power, ensure they are PoE or PoE+ compatible and connect them to the PoE+ enabled ports.
- For uplink connections to other network devices or the core network, use the SFP slots (17-18) with appropriate SFP transceivers and fiber optic cables.
5.3 بریښنا
- Connect the power cable to the AC inlet on the rear panel of the switch.
- Secure the power cable with the provided retention hook to prevent accidental disconnection.
- د بریښنا کیبل بله پای په مناسب AC بریښنا پلورنځي کې ولګوئ.
- The system will power on automatically. Observe the LED indicators on the front panel to confirm proper startup. The SYSTEM LED should turn green, and port LEDs will indicate link status and activity.
6. عملیات
6.1 Web GUI لاسرسی
سویچ د هغې له لارې اداره کیدی شي web-based graphical user interface (GUI).
- Ensure your computer is connected to the switch via an Ethernet cable and is on the same network segment.
- خلاص a web براوزر (د مثال په توګه، کروم، فایرفاکس، ایج).
- Enter the default IP address of the switch in the browser's address bar. (Refer to the product's quick start guide or default settings for the exact IP address, typically 192.168.1.1 or similar).
- Enter the default username and password when prompted. (These are usually provided in the quick start guide or on a label on the device).
- Upon successful login, you will access the Web GUI dashboard, where you can monitor and configure the switch.
6.2 بنسټیز ترتیب
د Web GUI allows for various configurations, including VLANs and QoS.
- د VLAN ترتیب: Navigate to the VLAN section to create, modify, or delete VLANs. Assign ports to specific VLANs to segment your network and improve security and performance.
- QoS Configuration: Access the QoS settings to prioritize network traffic. This is crucial for applications sensitive to latency, such as VoIP or video streaming, ensuring their smooth operation.
6.3 PoE+ Management
Monitor and manage Power over Ethernet Plus (PoE+) settings through the Web GUI.
- View the power consumption of connected PoE+ devices.
- Enable or disable PoE+ on individual ports.
- Set power priorities for ports to ensure critical devices receive power first in case of budget limitations.
7. ساتنه
7.1 د فرم ویئر تازه معلومات
Regularly check the Allied Telesis support website for the latest firmware versions. Firmware updates can provide new features, performance improvements, and security enhancements.
- وروستی فرم ویئر ډاونلوډ کړئ file from the official Allied Telesis webسایټ
- ته لاسرسی Web GUI and navigate to the firmware update section.
- د نوي فرم ویئر اپلوډ او نصبولو لپاره په سکرین کې لارښوونې تعقیب کړئ. د تازه کولو پروسې په جریان کې وسیله مه بندوئ.
Clean پاکول او پالنه
To ensure the longevity of your switch:
- وسیله پاکه او له دوړو څخه پاکه وساتئ. د پاکولو لپاره نرم، وچ ټوکر وکاروئ.
- مایع یا ایروسول پاکونکي مه کاروئ.
- ډاډ ترلاسه کړئ چې د وینټیلیشن خلاصونه بند شوي ندي.
8. ستونزه حل کول
دا برخه د هغو عامو ستونزو حلونه وړاندې کوي چې تاسو ورسره مخ کیدی شئ.
8.1 د LED شاخصونه
Understanding the LED indicators can help diagnose problems:
| LED | حالت | تفصیل |
|---|---|---|
| سیسټم | شنه (جامد) | سیسټم په نورمال ډول کار کوي. |
| سیسټم | بند | هیڅ ځواک یا سیسټم تېروتنه نلري. |
| PoE ON | شنه (جامد) | PoE power is supplied to the port. |
| PoE ERR | امبر (سخت) | PoE error detected on the port (e.g., overcurrent, short circuit). |
| LINK / ACT | شنه (جامد) | Valid network link established. |
| LINK / ACT | شنه (ځلیدونکی) | Data activity on the port. |
| LINK / ACT | بند | No link or cable issue. |
8.2 ګډې ستونزې او حل لارې
- ځواک نشته:
- Check if the power cable is securely connected to both the switch and the power outlet.
- ډاډ ترلاسه کړئ چې د بریښنا سایټ فعال دی.
- No Network Link:
- Ensure the Ethernet cable is properly connected to both the switch port and the connected device.
- Check the cable for damage. Try a different cable.
- ډاډ ترلاسه کړئ چې وصل شوی وسیله فعاله ده او په سمه توګه کار کوي.
- د PoE وسیله نه فعالیږي:
- Confirm the device is PoE/PoE+ compatible.
- Check the PoE ON LED for the port. If PoE ERR LED is on, there might be an issue with the device or cable.
- Verify the total PoE power budget of the switch is not exceeded.
- لاسرسی نشم کولی Web GUI:
- Ensure your computer's IP address is on the same subnet as the switch's IP address.
- Verify the switch is powered on and the network cable is connected.
- د خپل براوزر کیش پاکولو یا بل براوزر کارولو هڅه وکړئ.
- If the IP address was changed and forgotten, a factory reset might be necessary (refer to advanced manual for reset procedures).
9. مشخصات
| صفت | ارزښت |
|---|---|
| برانډ | متحد ټلویزیون |
| د ماډل شمیره | 4628R |
| د محصول ابعاد (W x D x H) | 44 x 25 x 4.4 سانتي متره |
| د محصول وزن | 4.46 کیلوګرامه |
| رنګ | خړ |
| ایترنیټ بندرونه | 16 x 10/100/1000BASE-T (PoE-OUT) |
| د SFP سلاټونه | 2 |
| د پوسټ معیار | IEEE 802.3at (PoE+) |
| د لومړي شتون نیټه | د ۲۰۲۲ کال د دسمبر ۵ مه |
10. د خوندیتوب معلومات
د وسیلې د ټپي کیدو او زیان څخه د مخنیوي لپاره لاندې خوندیتوب احتیاطي تدابیر په پام کې ونیسئ:
- Do not operate the device near water or in excessively humid environments.
- مناسبه ځمکه تضمین کړئ.
- وسیله مه خلاصوئ casinج. ټول خدمات وړ پرسونل ته راجع کړئ.
- Use only the power adapter and cables supplied or recommended by the manufacturer.
- د بریښنا تارونه د چلولو یا پنچ کیدو څخه خوندي کړئ.
- د وسیلې پاکولو یا حرکت کولو دمخه بریښنا قطع کړئ.
11. تضمین او ملاتړ
This product comes with a 5-year product warranty. For warranty claims or technical support, please contact your authorized Allied Telesis reseller or visit the official Allied Telesis support webسایټ
For the most up-to-date support resources, including FAQs, downloads, and contact information, please refer to: