LYCEBELL LC-5800G

LYCEBELL LC-5800G Professional Ammonia Gas Meter Detector User Manual

1. پیژندنه

This manual provides essential information for the safe and effective operation of your LYCEBELL LC-5800G Professional Ammonia Gas Meter Detector. This device is designed for continuous quantitative analysis of ammonia concentration, offering high precision and reliability for various applications.

2. د خوندیتوب معلومات

Ammonia gas (NH3) is a hazardous substance. Always exercise caution when operating this device in environments where ammonia may be present. The following table outlines potential health effects at various ammonia concentrations:

Concentration (PPM)Human Physiological Reaction
5-10Sensory odor threshold; some people may detect it.
20Most people have obvious irritation, generally harmless.
40Eye pain, tears for 30 minutes.
100Most people feel uncomfortable, harmless.
250Stimulates the nose, throat, eyes, and other senses.
700The limit that the human body can endure; not advisable to stay for more than 30 minutes, may cause permanent eye damage.
1700Severe cough, irritation of the nose, throat; 30 minutes may be fatal.
2500Severe cough, irritation of the nose, throat; 15 minutes may cause death.

Always ensure proper ventilation and evacuate the area immediately if alarm thresholds are exceeded. Do not attempt to repair or modify the device yourself.

3. محصول ختم شوview

The LYCEBELL LC-5800G is a professional handheld ammonia gas detector designed for accurate monitoring of NH3 levels, temperature, and humidity. It features an advanced electrochemical sensor for reliable readings.

کلیدي ځانګړتیاوې:

  • Ammonia Detection: Wide measurement range of 0-100 PPM with 0.1 PPM resolution and ±5% accuracy.
  • Multi-Functional Monitoring: Simultaneously measures temperature (-10℃ to 50℃) and humidity (0-95%RH). Temperature units are switchable between Celsius and Fahrenheit.
  • Two-Level Warning System: Adjustable high/low alarm thresholds with audible and visual signals (slow/fast beeps, flashing lights).
  • د چارج وړ بیټرۍ: Powered by a long-lasting lithium battery, supporting continuous operation.
  • اتومات بریښنا بند: Configurable automatic shutdown to conserve battery life.
  • Tripod-Mountable Design: Integrated tripod mounting hole for stable, hands-free measurements.

د وسیلې برخې:

Diagram showing the components of the LYCEBELL LC-5800G Ammonia Gas Detector, including the probe, display, alarm indicator light, temperature unit button, alarm setting button, increment button, mode button, power on/off button, decrement button, and tripod screw hole.
شکل 3.1: مخکی او شاته view of the LYCEBELL LC-5800G Ammonia Gas Detector with labeled components. Key parts include the sensor probe at the top, the large LCD display, control buttons for power, mode, alarm settings, and temperature unit conversion, and a tripod screw hole on the back.
  • Probe (Sensor): Located at the top, responsible for detecting ammonia gas. Keep it clear of obstructions.
  • ښکاره کول: Large LCD screen showing NH3 concentration, temperature, humidity, and battery status.
  • د الارم شاخص رڼا: Flashes during alarm conditions.
  • °C/°F تڼۍ: د سیلسیس او فارنهایټ د تودوخې واحدونو ترمنځ بدلیږي.
  • د بریښنا / بند تtonۍ: Central button to power the device on or off.
  • د حالت تڼۍ: Accesses settings and various display modes.
  • د الارم تنظیم کولو تڼۍ: Used to configure alarm thresholds.
  • Increment/Decrement Buttons: په ترتیباتو کې د نیویګیشن او ارزښتونو تنظیم کولو لپاره کارول کیږي.
  • Tripod Screw Hole: Located on the back for mounting the device on a tripod.
  • د چارج کولو انٹرفیس: د داخلي بیټرۍ د چارجولو لپاره USB پورټ.

4. ترتیب کول

4.1 ابتدايي چارج کول

Before first use, fully charge the device using the provided USB cable. Connect the USB cable to the charging interface on the device and a compatible USB power source. The charging indicator light will show the charging status (e.g., red for charging, green for fully charged).

Close-up of the LYCEBELL LC-5800G Ammonia Gas Detector showing the sensor, charging port, and LED indicators for charging status. Text indicates battery life up to 30 hours, red light for fully charged, and green light for charging.
شکل 4.1: The device's sensor and charging port. The charging port is a standard USB connection, and LED indicators show charging status.

4.2 بریښنا کول / بندول

To power on the device, press and hold the central power button. The display will illuminate, and the device will perform a self-test. To power off, press and hold the power button again. The device also supports an automatic power-off function, which can be configured in the settings.

5. عملیاتي لارښوونې

5.1 بنسټیز عملیات

Once powered on, the device will display the current ammonia concentration in PPM, along with temperature and humidity readings. Ensure the sensor probe is exposed to the environment you wish to monitor.

The LYCEBELL LC-5800G Ammonia Gas Detector displaying 0.0 PPM for NH3, 55% RH for humidity, and 19.2°C for temperature. A small carrying case is also shown.
شکل 5.1: The device displaying ammonia concentration, humidity, and temperature readings.

5.2 د حرارت د واحدونو بدلول

Press the '°C/°F' button to switch the temperature display between Celsius and Fahrenheit.

5.3 Setting Alarm Thresholds

The device features two adjustable alarm levels: AL1 (first alarm) and AL2 (second alarm). To set these:

  1. Press the 'ALARM' button to enter the alarm setting state.
  2. Use the increment/decrement buttons to adjust the AL1 value.
  3. Press the 'ALARM' button again to switch to AL2 setting.
  4. Use the increment/decrement buttons to adjust the AL2 value.
  5. Press the 'MODE' button to exit the alarm setting state.

When ammonia levels reach or exceed the set thresholds, the device will trigger audible and visual alarms. The alarm sound is approximately 80 dB.

5.4 اتومات بریښنا بند (APO)

The device can be configured for automatic power off to save battery. To adjust this setting:

  1. Press the 'MODE' button to enter the settings menu.
  2. Navigate to the 'TIM SHUT' option using the increment/decrement buttons.
  3. Press 'OK' (central power button) to enter the APO setting.
  4. Toggle between 'APO ON' (auto power off enabled) and 'APO OFF' (auto power off disabled) using the increment/decrement buttons.
  5. Press 'OK' to confirm your selection and 'ESC' to exit the menu.

5.5 غوښتنلیکونه

This ammonia gas detector is suitable for a wide range of applications, including:

  • Poultry farms, pig farms, horse stables, and other livestock facilities.
  • Fish farms and animal welfare shelters.
  • Cold storage rooms and laboratories.
  • Waste management and chemical industries.
  • Environmental protection and other fields requiring ammonia monitoring.
Collage of images showing the ammonia gas detector in various agricultural settings, including poultry farms, pig farms, horse stables, and fish farms.
شکل 5.2: The LYCEBELL LC-5800G in various application environments.

6. ساتنه

To ensure the longevity and accuracy of your device:

  • Keep the sensor probe clean and free from dust or debris. Use a soft, dry cloth for cleaning.
  • وسیله په یخ او وچ ځای کې د مستقیم لمر وړانګو او سختې تودوخې څخه لرې وساتئ.
  • د مطلوب فعالیت ساتلو لپاره په منظم ډول بیټرۍ چارج کړئ.
  • د قوي تاثیراتو سره د وسیله له مینځه وړلو یا تابع کولو څخه ډډه وکړئ.
  • Do not expose the device to corrosive liquids or gases other than those it is designed to detect.

7. ستونزه حل کول

If you encounter issues with your device, consider the following:

  • وسیله نه چلیږي: ډاډ ترلاسه کړئ چې بیټرۍ په بشپړ ډول چارج شوې.
  • ناسم لوستل: Check if the sensor probe is clean and unobstructed. Ensure the device has been allowed sufficient time to stabilize in the environment.
  • الارم نه غږیږي: Verify that alarm thresholds are set correctly and the volume is not muted (if applicable).
  • د بیټرۍ لنډ ژوند: Ensure the device is fully charged. Consider enabling the auto power off (APO) function.

د دوامداره ستونزو لپاره، مهرباني وکړئ د پیرودونکو ملاتړ سره اړیکه ونیسئ.

8. مشخصات

پیرامیټرارزښت
د کشف ګازامونیا (NH3)
د اندازه کولو رینج0-100ppm
قرارداد0.1ppm
بنسټیزه تېروتنهLess than ±5% (F.S)
د غبرګون وختله 120 ثانیو څخه لږ
د بیا رغونې وختله 240 ثانیو څخه لږ
د تکرار وړتیاLess than ±1%
د سینسر اصولElectrochemical principle, life for two years
بیټرۍLithium battery (rechargeable)
ښودلLarge screen liquid crystal display
الارمAcoustic, optical double alarm, set the alarm value, an alarm sound is divided into 80 dB
د کار د حرارت درجه-20 ℃ ~ 50 ℃
کاري رطوبت0-95%RH (Non Gel)
د محصول ابعاد6.8 x 2.8 x 0.7 انچه
د توکي وزن14.82 اونس

9. د بسته محتويات

لاندې توکي ستاسو د محصول په کڅوړه کې شامل دي:

  • 1x LYCEBELL LC-5800G Ammonia Gas Detector
  • 1x USB کیبل
  • د 1x ذخیره کڅوړه
  • 1x د کارونکي لارښود
Image showing the LYCEBELL LC-5800G Ammonia Gas Detector, a USB cable, a storage bag, and the user manual, all neatly arranged next to the product box.
شکل 9.1: All items included in the LYCEBELL LC-5800G product package.

۱۱. د محصول ویډیو پای ته ورسیدهview

Watch this video for a visual guide on the LYCEBELL LC-5800G Ammonia Gas Detector's features and operation.

ویډیو 10.1: یو اوورview of the LYCEBELL LC-5800G Ammonia Gas Detector, demonstrating its functions and key features.

11. تضمین او ملاتړ

For warranty information or technical support, please refer to the contact details provided in the packaging or visit the official LYCEBELL webسایټ د تضمین ادعاګانو لپاره خپل د پیرود رسید وساتئ.

اړوند اسناد - LC-5800G

مخکېview د لایسبیل LC-7200B DC/AC True-RMS Clamp د ملټي میټر عملیاتو لارښود
د LYCEBELL LC-7200B DC/AC True-RMS Cl لپاره د کارونکي لارښودamp ملټي میټر. د حجم اندازه کولو لپاره مفصل عملیاتي لارښوونې، د خوندیتوب لارښوونې، تخنیکي مشخصات، او کارول چمتو کوي.tage، جریان، مقاومت، ظرفیت، فریکونسي، تودوخه، او NCV.
مخکېview د AOPUTTRIVER AR8500 امونیا ګاز کشف کونکي کارونکي لارښود او تخنیکي مشخصات
د AOPUTTRIVER AR8500 امونیا ګاز کشف کونکي لپاره جامع لارښود لارښود. د دې دقیق اندازه کولو وسیلې لپاره د محصول توضیحات، تخنیکي پیرامیټرې، عملیات، ساتنه، او د خوندیتوب احتیاطي تدابیر پوښي.
مخکېview د LC-881W WBGT انیمومیټر لارښود: د باد سرعت، تودوخه، رطوبت اندازه کول
د LC-881W WBGT انیمومیټر لپاره رسمي عملیاتي لارښود. زده کړئ چې څنګه د باد سرعت، تودوخې، رطوبت، او په بهر او صنعتي غوښتنلیکونو کې د تودوخې فشار څارنې لپاره د WBGT اندازه کولو لپاره دا 3-in-1 لاسي میټر وکاروئ.
مخکېview Dräger Pac 6x00 / 8x00 Series Gas Detector Approvals and Specifications
Technical specifications, approvals, and regulatory compliance for Dräger Pac 6000, Pac 8000, Pac 8500, and Pac 6500 series portable gas detectors, including sensor data and environmental operating conditions.
مخکېview د رایس لیک MAS-LC سټیشنري څارویو پیمانه نصبولو لارښود
د رایس لیک MAS-LC سټیشنري څارویو پیمانه لپاره د نصبولو لارښود، د تنظیم، ساتنې، ستونزو حل کولو، او مشخصاتو لپاره تفصيلي لارښوونې چمتو کوي. د دې صنعتي وزن کولو سیسټم لپاره خوندیتوب، پورته کول، نصب کول، پرزې، او ساتنې پروسیجرونه پوښي.
مخکېview د DSC LC-181 اوکټا کواډ بهرنۍ حرکت کشف کونکي نصبولو لارښود
د DSC LC-181 Octa-Quad بهرنۍ عکس کشف کونکي لپاره د ماسک ضد ټیکنالوژۍ سره د نصب کولو تفصيلي لارښوونې. د ځانګړتیاوو، مشخصاتو او تنظیم په اړه زده کړه وکړئ.