LYCEBELL T8-W7L

LYCEBELL 7-in-1 Water Quality Tester Instruction Manual

Model: T8-W7L

1. محصول ختم شوview

This manual provides instructions for the LYCEBELL 7-in-1 Water Quality Tester, Model T8-W7L. This device is designed to accurately measure multiple water parameters including pH, Electrical Conductivity (EC), Total Dissolved Solids (TDS), Oxidation-Reduction Potential (ORP), Specific Gravity (S.G), Salinity, and Temperature. It is suitable for various applications such as testing drinking water, aquariums, aquaculture, laboratories, and pools.

کلیدي ځانګړتیاوې

LYCEBELL 7-in-1 Water Quality Tester showing its display and probe in water

Image 1.1: The LYCEBELL 7-in-1 Water Quality Tester in use, highlighting its multi-functionality and clear LCD screen.

2. د محصول اجزا او ابعاد

The device consists of a main body with an LCD screen, control buttons, a high-precision probe, and a battery compartment. Understanding these components is essential for proper operation and maintenance.

Diagram of LYCEBELL 7-in-1 Water Quality Tester showing its parts and dimensions

Image 2.1: Detailed diagram illustrating the components of the water quality tester, including the HD LCD screen, ON/OFF button, HOLD/TEMP button, MODE/CAL button, high-precision probe, pen cap, and battery location. Dimensions are also shown: 7.2 inches (183mm) length and 1.18 inches (37mm) width.

3. ترتیب کول

د بیټرۍ نصب کول

The device uses three 1.5V button batteries. To install or replace batteries, unscrew the cap at the top of the device. Insert the batteries according to the polarity markings. Securely screw the cap back on.

Close-up of the battery compartment of the water quality tester

انځور ۲: یوه نږدې انځور view of the battery compartment, showing the placement of the three 1.5V button batteries.

ابتدايي بریښنا فعاله ده

Press the "ON/OFF" button to power on the device.

4. عملیات

اندازه کول

  1. د پروب څخه محافظتي خولۍ لرې کړئ.
  2. Rinse the probe with distilled water and blot dry with a clean tissue.
  3. Press the "ON/OFF" button to turn on the meter.
  4. Dip the electrode into the solution to be measured, ensuring the liquid level is below the immersion line.
  5. Gently stir the solution and wait for the reading to stabilize on the LCD display.

د اندازه کولو طریقې بدلول

Press the "MODE/CAL" button to cycle through the different measurement modes: pH, EC, TDS, Salinity, S.G, ORP, and Temperature. The current mode will be displayed on the screen.

Display showing different measurement modes of the water quality tester

Image 4.1: The meter's display cycling through various measurement modes such as pH, µS/cm (EC), ppm (TDS), % (Salinity), S.G, and mV (ORP).

Holding Readings and Temperature Unit Switching

Press the "HOLD/TEMP" button briefly to lock the current reading on the display. Press it again to release.

Long-press the "HOLD/TEMP" button to switch between Celsius (°C) and Fahrenheit (°F) temperature units.

کیلیبریشن

The meter offers instant one-touch calibration. Refer to the included calibration powders for specific instructions on preparing calibration solutions.

  1. Prepare the calibration solution (e.g., pH 6.86, pH 4.00, pH 9.18 for pH calibration).
  2. Turn on the meter and select the desired measurement mode (e.g., pH).
  3. Dip the probe into the calibration solution.
  4. Long-press the "MODE/CAL" button until the calibration mode is activated (usually indicated by a flashing reading or "CAL" on the screen).
  5. The meter will automatically recognize the standard solution and calibrate itself. Wait for the reading to stabilize and the calibration to complete.
  6. د کیلیبریشن وروسته پروب د تشو اوبو سره ومینځئ.

یادونه: Regular calibration is crucial for maintaining measurement accuracy, especially for pH.

5. ساتنه

د پلټنې پاملرنه

Always keep the probe clean. After each use, rinse the electrode with distilled water.

Store the probe with the protective cap on, ideally with a small amount of KCL storage solution or distilled water to prevent the electrode from drying out.

Close-up of the highly sensitive electrode probe

انځور ۲: یوه نږدې انځور view of the highly sensitive electrode probe, emphasizing the importance of its cleanliness for accurate measurements.

د پنروک درجه

The device has an IP67 waterproof rating, meaning it is protected against dust ingress and short-term immersion in water (up to 1 meter for 30 minutes). Avoid prolonged submersion or exposure to high-pressure water.

Image illustrating the IP67 waterproof rating of the water quality tester

Image 5.2: The water quality tester being used near a pool, demonstrating its IP67 waterproof capability.

د بیټرۍ بدلول

Replace batteries when the low battery indicator appears on the screen or when the device fails to power on. Follow the battery installation steps in the "Setup" section.

6. ستونزه حل کول

ناسم لوستل

وسیله فعاله نه ده

د ښودلو مسلې

که چیرې ښودنه تیاره یا ځلیږي، بیټرۍ بدل کړئ.

7. مشخصات

تخنیکي مشخصات

Table of technical specifications for the 7-in-1 water quality tester

Image 7.1: A detailed table outlining the measurement ranges, resolutions, and accuracies for each parameter (TDS, EC, PH, SALT, S.G, TEMP, ORP).

د اندازه کولو پیرامیټونه
شاخصرینجقرارداددقت
TDS0-200000ppm; 10.1-100.0ppt (effective range)۰.۱ پی پی ایم؛ ۰.۱ پی پی ټي± 2 F FS
EC0-200000µS/cm; 10.1-200.0mS/cm (effective range)۱µS/سانتي متره؛ ۰.۱ ملی ایس/سانتي متره± 2 F FS
PH0.00-14.000.01±0.05
سالټ0.01-25.00%; 0-10000ppm; 10.1-200.0ppt0.01%; 1ppm; 0.1ppt0.01-5.00% (±0.1%); 5.1%-25.00% (±1%); ±2% F.S
SG1.000-1.222//
TEMP0-60°C / 32-140°F1°C/1°F±0.5°C
ORP±1999mV1mV±2mV
عمومي مشخصات
صفتارزښت
د محصول ابعاد4.2 x 2.1 x 5.3 انچه
د توکي وزن10.6 اونس
جوړونکیLC
د توکي ماډل شمیرهT8-W7L
ASINB0CNPFZ5QM

8. تضمین او ملاتړ

د تضمین معلومات

Warranty information for this product is not available in the provided data. Please refer to the product packaging or contact LYCEBELL customer support for details regarding warranty terms and conditions.

د پیرودونکي ملاتړ

For technical assistance, troubleshooting, or any other support inquiries, please contact LYCEBELL customer service. Contact details are typically found on the product packaging or the official LYCEBELL webسایټ

اړوند اسناد - T8-W7L

مخکېview د لایسبیل LC-7200B DC/AC True-RMS Clamp د ملټي میټر عملیاتو لارښود
د LYCEBELL LC-7200B DC/AC True-RMS Cl لپاره د کارونکي لارښودamp ملټي میټر. د حجم اندازه کولو لپاره مفصل عملیاتي لارښوونې، د خوندیتوب لارښوونې، تخنیکي مشخصات، او کارول چمتو کوي.tage، جریان، مقاومت، ظرفیت، فریکونسي، تودوخه، او NCV.
مخکېview د T8 محصول لارښود: د نصبولو، عملیاتو، او ساتنې لارښود
د T8 محصول لپاره جامع کارونکي لارښود، چې د نصبولو، تنظیم کولو، عملیاتو، ساتنې، ستونزو حل کولو، او خوندیتوب لارښوونو په اړه مفصل لارښوونې چمتو کوي. د ټولو T8 کاروونکو لپاره اړین لوستل.
مخکېview Tele Radio T60 T8-MN Installation Instructions
Installation instructions for the Tele Radio T60 T8-MN series remote control transmitters, covering technical data, battery handling, and disposal.
مخکېview HOFTRONIC T8 & T5 LED Tubes User Manual and Installation Guide
Comprehensive user manual and installation guide for HOFTRONIC T8 and T5 LED tubes, covering safety, specifications, applications, and installation procedures. Features include high lumen efficiency, energy saving, and long lifespan.
مخکېview د LEDVANCE سبسټیوټیب T8 یونیورسل LED ټیوب نصبولو او عملیاتو لارښود
دا لارښود د LEDVANCE SubstiTUBE T8 UNIVERSAL LED ټیوب د نصب او عملیاتو لپاره اړین معلومات او لارښوونې چمتو کوي. دا د بریښنایی کنټرول ګیرونو (ECGs) سره مطابقت، د مختلف بیلسټ ډولونو (HF، EM، Mains) لپاره د نصب کولو پروسیجرونه، او مهم عملیاتي ملاحظات لکه د تودوخې محدودیتونه او د رڼا ویش توضیح کوي. دا لارښود په څو ژبو کې شتون لري.
مخکېview د RAB LED T8 واحد/دوه اړخیزه هایبرډ نصبولو لارښود
Comprehensive installation guide for RAB LED T8 Single/Double Ended Hybrid tubes, covering ballast compatible and ballast bypass wiring methods for various fluorescent luminaire types. Includes safety warnings, product specifications, and installation steps.