ACiQ RXNG09AXVJU / FTXNG09AXVJU

Goodman Mini-Split AC/Heating System E-Series User Manual

Model: RXNG09AXVJU / FTXNG09AXVJU | Brand: ACiQ

پیژندنه

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman Mini-Split AC/Heating System E-Series. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide efficient heating and cooling for residential and light commercial applications.

تنظیم او نصب کول

The Goodman Mini-Split AC/Heating System E-Series includes an indoor wall-mounted air handler unit, an outdoor mini-split heat pump condenser, and a comprehensive installation kit. Professional installation is recommended for optimal performance and safety.

اجزا شامل دي

Goodman Mini-Split AC/Heating System E-Series with all components

شکل 1: پایview of the Goodman Mini-Split AC/Heating System E-Series and its included components, showing the indoor unit, outdoor unit, remote control, and installation kit elements.

د نصبولو په اړه نظرونه

Ensure the installation area for both indoor and outdoor units meets the required clearances for proper airflow and maintenance. The system operates on 208/230V, 1 Phase, 60Hz power. The 0.75-ton unit is designed to efficiently heat and cool areas up to 400 square feet.

ACiQ Mini Split Installation Kit components

شکل 2: مفصل view of the ACiQ Mini Split Installation Kit, including line sets, control wire, drain tube, wall mount bracket, and line cover guards.

عملیاتي لارښوونې

Your Goodman E-Series Mini-Split system offers various modes and features for optimal comfort and energy efficiency.

د عملیاتو اساسي طریقې

کلیدي ځانګړتیاوې او کنټرولونه

Goodman E-Series Mini-Split features list

Figure 3: Illustration of the key features of the Goodman E-Series Mini-Split system, including remote control, auto-restart, self-diagnosis, and various operational modes.

ساتنه

Regular maintenance ensures the longevity and efficient operation of your mini-split system. Always disconnect power to the unit before performing any maintenance.

د فلټر پاکول

The system is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage and air quality. Refer to the specific instructions in your full product manual for filter removal and cleaning procedures. Generally, filters can be gently vacuumed or washed with lukewarm water and mild detergent, then air-dried completely before reinstallation.

Drain Pan Maintenance

The indoor unit features a removable dirt-water drain pan. Periodically inspect and clean the drain pan to prevent mold growth and blockages, which can lead to water leaks. Ensure the drain tube is clear and free of obstructions.

د واحد پاکول

The indoor unit has a wipe-clean flat panel. Use a soft, damp cloth to clean the exterior surfaces. Do not use harsh chemicals or abrasive cleaners. For the outdoor unit, ensure the coils are free of debris and obstructions. The outdoor unit also features anti-corrosion treatment for enhanced durability.

د ستونزو حل کول

Before contacting customer support, please refer to the following common issues and solutions. The self-diagnosis feature with a digital display can provide initial indications of problems.

ستونزهاحتمالي لاملد حل لاره
واحد نه خلاصیږيNo power, remote control batteries low, unit switch off.Check power supply, replace remote batteries, ensure indoor unit ON/OFF switch is engaged.
ناکافي تودوخه/یخونهDirty air filters, blocked outdoor unit, incorrect mode/temperature setting, refrigerant leak.Clean filters, clear obstructions from outdoor unit, verify settings, contact professional for refrigerant check.
غیر معمولي شورLoose parts, fan obstruction, refrigerant flow noise (normal).Inspect for loose parts or obstructions. If noise persists or is abnormal, contact service.
د داخلي واحد څخه د اوبو لیکیدلClogged drain pan/tube, improper installation.Clean drain pan and tube. If issue persists, professional inspection is required.
Digital display shows error codeد داخلي سیسټم نیمګړتیا.Note the error code and consult the full product manual or contact customer support for specific guidance.

For issues not listed or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or ACiQ customer support.

مشخصات

Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).

صفتارزښت
د برانډ نومACiQ
د ماډل معلوماتRXNG09AXVJU / FTXNG09AXVJU
BTU Capacity (Cooling)۱۵۰۰۰ BTU (۱.۲۵ ټنه)
BTU Capacity (Heating)4,400 BTU – 13,000 BTU
SEER2 Efficiency18 SEER2
والیtage208/230 Volts, 1 Phase, 60Hz
د شور کچه (بهرنی واحد)56 dB
د لګولو ډولسلیټ سیسټم
د فارم فکتورکوچنی ویش
یخچالR 410A
وړاندیز شوی پوښښ ساحهتر 400 مربع فوټ پورې
Goodman Mini-Split AC/Heating System dimensions and specifications

Figure 4: Dimensional specifications and performance ratings for the Goodman Mini-Split AC/Heating System, including BTU, square footage coverage, and noise levels.

تضمین او ملاتړ

For warranty information, please refer to the warranty card included with your product or visit the official ACiQ website. Warranty terms typically cover manufacturing defects and vary by component.

For technical support, service requests, or to inquire about replacement parts, please contact ACiQ customer service. Have your model number (RXNG09AXVJU / FTXNG09AXVJU) and purchase date ready when contacting support.

آنلاین سرچینې: For additional resources, FAQs, and product registration, visit the په ایمیزون کې د ACiQ پلورنځی.

اړوند اسناد - RXNG09AXVJU / FTXNG09AXVJU

مخکېview د ACiQ 9K-24K معیاري تودوخې واحد زون سیسټمونه: نصب او د مالک لارښود
د ACiQ 9K-24K معیاري تودوخې واحد زون سیسټمونو نصب او د مالک لارښود. دا لارښود د ACiQ ایر کنډیشنرونو نصب، عملیات، خوندیتوب، او ساتنې توضیحات ورکوي، پشمول د ماډل مشخصات او د R454B یخچال معلومات.
مخکېview ACiQ R32 Multi-Zone Condenser & Wall Mounted Air Handler Troubleshooting Guide
This troubleshooting guide provides detailed steps and solutions for common faults and errors encountered with ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler systems, including sensor faults, communication errors, and component issues.
مخکېview د ACiQ 9K-24K معیاري تودوخې واحد زون سیسټمونه: نصب او د مالک لارښود
Comprehensive installation and owner's manual for ACiQ 9K-24K Standard Heat Single-Zone Systems, covering setup, operation, maintenance, and troubleshooting for various ACiQ models.
مخکېview د ACiQ دیوال نصب شوی هوایی هینډلر او د خورا تودوخې واحد زون کنډنسر نصب او د مالک لارښود
دا لارښود د ACiQ دیوال نصب شوي هوایی هینډلرونو او د خورا تودوخې واحد زون کنډنسرونو لپاره د نصب، عملیاتو او خوندیتوب تفصيلي لارښوونې چمتو کوي، چې د ACIQ-06W-HH-MD څخه تر ACIQ-24ZPL-HP230C ماډلونه پوښي.
مخکېview ACiQ R32 Multi-Zone Condenser & Wall Mounted Air Handler Service & Technical Manual
Comprehensive service and technical manual for ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler units. This guide provides detailed information on installation, operation, troubleshooting, and maintenance for models ACiQ-09W-E-M, ACiQ-12W-E-M, ACiQ-18W-E-M, ACiQ-18Z-E-M2, and ACiQ-24Z-E-M3.
مخکېview ACiQ Central Heat Pump Split System Owner's Manual & Operating Guide
Comprehensive owner's manual for ACiQ Central Heat Pump Split Systems, covering safety precautions, operating conditions, features, energy saving tips, care and maintenance, and troubleshooting for models ACiQ-24, ACiQ-36, and ACiQ-48.