Pulsar PGiPAIRB4

Pulsar PGiPAIRB4 Inverter Generator Parallel Kit

د لارښوونې لارښود

پیژندنه

This manual provides essential instructions for the safe and efficient use of your Pulsar PGiPAIRB4 Inverter Generator Parallel Kit. This kit allows you to connect two compatible Pulsar inverter generators to double their power output, providing increased electrical capacity for various applications, including RV use.

Compatible Pulsar Generator Models: PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO.

د خوندیتوب معلومات

Always read and understand all safety warnings and instructions in this manual and the manuals of your connected generators before operation. Failure to follow these instructions can result in serious injury or property damage.

  • Ensure all connections are secure before starting generators.
  • Operate generators in a well-ventilated area to prevent carbon monoxide poisoning.
  • په لوند شرایطو کې کار مه کوئ.
  • Keep children and pets away from operating equipment.
  • Always turn off generators and disconnect spark plug wires before performing any maintenance or making connections.

د بسته محتويات

ډاډ ترلاسه کړئ چې ټول توکي ستاسو په کڅوړه کې شتون لري:

  • Pulsar PGiPAIRB4 Parallel Kit Unit
  • Connection Cables (integrated)
  • د کارونکي لارښود (دا لاسوند)
Pulsar PGiPAIRB4 Parallel Kit unit with cables

Image: The Pulsar PGiPAIRB4 Parallel Kit unit, showing the main box with receptacles and circuit breakers, and the integrated connection cables extending from it.

تنظیم او پیوستون

Follow these steps to connect your parallel kit to two compatible Pulsar inverter generators:

  1. چمتووالی: Ensure both generators are turned off, cooled down, and disconnected from any loads. Place the generators on a level, stable surface in a well-ventilated area.
  2. Connect Parallel Cables: Locate the parallel connection ports on each generator. These are typically color-coded (red and black) and may have specific shapes.
    Close-up of parallel connection cables

    انځور: نږدې انځور view of the parallel kit's connection cables, showing the red and black connectors designed to plug into the generators.

    Connect the red cable from the parallel kit to the red parallel port on the first generator. Connect the black cable from the parallel kit to the black parallel port on the first generator. Repeat this process for the second generator.
    Close-up of parallel connection adapters

    Image: Various parallel connection adapters and plugs, illustrating the types of connections used for linking generators.

  3. خوندي اړیکې: Ensure all connections are firmly seated and secure. Loose connections can cause arcing or power interruptions.
  4. وروستۍ ځای پر ځای کول: Position the parallel kit unit in a safe, accessible location, away from exhaust fumes and moisture.
    Two Pulsar generators connected with the parallel kit

    Image: Two Pulsar inverter generators shown from the rear, with the PGiPAIRB4 Parallel Kit connected to their respective parallel ports, demonstrating a complete setup.

عملیاتي لارښوونې

Once the parallel kit is securely connected to both generators:

  1. Start Generators: Start both inverter generators according to their individual operating instructions. Allow them to run for a few moments to stabilize.
  2. د نښلولو بارونه: Plug your electrical loads into the receptacles on the PGiPAIRB4 Parallel Kit.
    • The L14-50 receptacle provides 120/240V output at 50 amps.
    • The L14-30 receptacle provides 120/240V output at 30 amps.
  3. څارنه: Observe the generator and parallel kit for proper operation. The circuit breakers on the parallel kit will trip if an overload occurs.
  4. ‍‍‍بندول: To shut down, first disconnect all loads from the parallel kit. Then, turn off both generators according to their individual instructions. Finally, disconnect the parallel kit cables.

ساتنه

The Pulsar PGiPAIRB4 Parallel Kit requires minimal maintenance. Follow these guidelines:

  • Keep the unit clean and free of dirt, dust, and moisture.
  • Inspect cables and connectors regularly for any signs of wear, damage, or corrosion. Replace if necessary.
  • Store the kit in a dry, protected area when not in use.

د ستونزو حل کول

ستونزهاحتمالي لاملد حل لاره
No power output from parallel kit.
  • Generators not started.
  • نرمې اړیکې.
  • سرکټ ماتونکی ټکر شو.
  • Incompatible generators.
  • Ensure both generators are running.
  • Check all parallel cable connections.
  • Reset the circuit breaker on the parallel kit.
  • Verify generators are listed as compatible models.
د سرکټ ماتونکی ډیری وخت ټکر کوي.
  • د اوورلوډ حالت.
  • Faulty appliance.
  • Reduce the total electrical load.
  • Test appliances individually to identify faulty ones.

مشخصات

  • ماډل: PGiPAIRB4
  • د محصول Voltage: 120/240V
  • د تولید فریکونسی: 60Hz
  • L14-50 Receptacle: 50 Amps
  • L14-30 Receptacle: 30 Amps
  • مطابقت لرونکي جنراتورونه: Pulsar PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO
  • د محصول ابعاد: 12 x 9 x 4 انچه
  • د توکي وزن: ۲.۴۵ پونډه
  • جوړونکی: پلسر

د تضمین معلومات

For detailed warranty information regarding your Pulsar PGiPAIRB4 Parallel Kit, please refer to the warranty card included with your purchase or visit the official Pulsar Products webسایټ. د تضمین ادعاوو لپاره د پیرود ثبوت وساتئ.

د پیرودونکي ملاتړ

If you have any questions, require technical assistance, or need to order replacement parts, please contact Pulsar Customer Support:

  • Webسایټ: www.pulsarproducts.com
  • Refer to your product registration or warranty documentation for specific contact numbers or email addresses.

اړوند اسناد - PGiPAIRB4

مخکېview Pulsar 9500 Watt Dual Fuel Inverter Generator Operator's Manual
This operator's manual provides comprehensive instructions for the Pulsar PGD95BiSCO 9500 Watt Dual Fuel Inverter Generator, covering safety precautions, operation, maintenance, and troubleshooting.
مخکېview د پلسر PG2200BiS انورټر ګازولین جنراتور چلونکي لارښود
د پلسر PG2200BiS پورټ ایبل انورټر ګازولین جنراتور لپاره جامع آپریټر لارښود، چې د باور وړ فعالیت ډاډمن کولو لپاره خوندیتوب، عملیات، ساتنه، او ستونزې حل کول پوښي.
مخکېview د پلسر PG2000iS/PG2300iS پورټ ایبل انورټر جنریټر آپریټر لارښود
This operator's manual provides essential information for the safe operation, assembly, maintenance, and troubleshooting of the Pulsar PG2000iS and PG2300iS portable inverter gasoline generators. Learn how to use your generator effectively and safely.
مخکېview د پلسر ۱۶۰۰ واټ انورټر جنراتور چلونکي لارښود PGD16iSCO
د پلسر PGD16iSCO 1600 واټ انورټر جنراتور لپاره جامع آپریټر لارښود. د خوندي او مؤثره کارونې لپاره مفصل خوندیتوب لارښوونې، عملیاتي پروسیجرونه، د ساتنې مهالویشونه، د ستونزو حل کولو لارښوونې، او تخنیکي مشخصات پکې شامل دي.
مخکېview Pulsar PG2300iSCO Inverter Gasoline Generator Operator's Manual
Comprehensive operator's manual for the Pulsar PG2300iSCO Inverter Gasoline Generator. This guide covers essential information including safety rules, product features, assembly instructions, detailed operation procedures, maintenance schedules, troubleshooting tips, and a wiring diagram for safe and effective use of the generator.
مخکېview د پلسر PG4500BiSRCO انورټر جنراتور چلونکي لارښود
د پلسر PG4500BiSRCO انورټر جنراتور لپاره د آپریټر لارښود، چې د پټرول او LPG دوه ګوني سونګ توکو کارولو لپاره خوندیتوب، ځانګړتیاوې، عملیات، ساتنه، او ستونزې حل کوي.