The Fluke 107 is a compact, handheld digital multimeter designed for basic electrical measurements. It provides accurate readings for voltage, current, resistance, capacitance, frequency, and duty cycle, along with continuity and diode test functions. Its portable design makes it suitable for various applications, from professional use to hobbyist projects.

انځور: مخکینۍ برخه view of the Fluke 107 Digital Multimeter, displaying its screen, rotary dial, and function buttons.
د خوندیتوب معلومات
د بریښنایی ازموینې تجهیزاتو کارولو پرمهال تل د خوندیتوب احتیاطي تدابیر مراعات کړئ. د دې کولو کې پاتې راتلل ممکن د ازموینې لاندې میټر یا تجهیزاتو ته د ټپي کیدو یا زیان لامل شي.
- مه کوه apply more than the rated voltage, as specified in the specifications section, between terminals or between any terminal and earth ground.
- مه کوه use the meter if it is damaged or operating abnormally. Inspect the case and test leads before use.
- مه کوه use the meter around explosive gas, vapor, or in damp یا لوند چاپیریال.
- د خپلو اندازه کولو لپاره تل سم ټرمینلونه، فعالیت، او حد وکاروئ.
- محتاط اوسئ کله چې د حجم سره کار کوئtagد 30V AC RMS، 42V چوکۍ، یا 60V DC څخه پورته. دا حجمونهtagد شاک خطر رامنځته کوي.
- د سرکټ بریښنا منحل کړئ او ټول لوړ حجم خارج کړئtage capacitors مخکې له دې چې د مقاومت، دوام، diodes، یا capacitance ازموینه وکړي.
- Ensure the test leads are fully seated in the meter's input jacks.
- کله چې د بیټرۍ ټیټ شاخص څرګند شي نو سمدلاسه بیټرۍ بدله کړئ ترڅو دقیق لوستل ډاډمن شي.
په بکس کې څه دي
The Fluke 107 package typically includes the following components:
- فلوک ۱۱۷ ډیجیټل ملټي میټر
- TL75 Test Leads (Hard Point Test Leads)
- 2 AAA Batteries (Installed)
- Smart Strap Magnetic Lanyard
- User Manual (printed safety information booklet)

Image: The Fluke 107 Multimeter displayed alongside its included test leads and magnetic lanyard.
چمتو کول
د بیټرۍ نصب کول
The Fluke 107 comes with two AAA batteries pre-installed. If replacement is needed:
- ډاډ ترلاسه کړئ چې ملټي میټر بند دی.
- د میټر په شا کې د بیټرۍ کڅوړه ومومئ.
- Open the battery compartment cover by twisting the lock and sliding it open.
- Remove the old batteries and insert two new AAA batteries, observing the correct polarity (+/-).
- د بیټرۍ کمپارټ پوښ په خوندي ډول وتړئ.
د ټیسټ لیډونو سره وصل کول
The Fluke 107 has three recessed banana jacks:
- A: For current measurements (up to 10A).
- COM: Common terminal for all measurements (black test lead).
- VΩHz: د جلد لپارهtage, resistance, capacitance, frequency, and diode tests (red test lead).
Always connect the black test lead to the COM jack. Connect the red test lead to the appropriate jack based on the measurement you intend to perform.
Using the Smart Strap Magnetic Lanyard
The included Smart Strap allows for hands-free operation by attaching the meter to a ferrous metal surface or by configuring it as a stand. The strap has a slot that fits into the meter's case and secures with Velcro. The magnetic end can then be used to attach the meter to metal surfaces or to itself to form a viewing stand.
عملیاتي لارښوونې
کنترول ختم شوview
The Fluke 107 features a central rotary selector knob and three soft-touch buttons:
- د روټري انتخاب کونکی نوب: Used to select the desired measurement function (OFF, AC Volts, DC Volts, AC mV, Ohms/Continuity/Diode, Capacitance, AC/DC Amps).
- تOLDۍ ت .ۍ: Freezes the current reading on the display. Press again to resume live readings.
- Hz % Button: Toggles between frequency (Hz) and duty cycle (%) display when measuring AC Volts or AC Amps.
- Yellow Function Button:
- In AC/DC Amps mode: Toggles between AC and DC current measurement.
- In Ohms mode: Toggles between resistance, continuity test, and diode test.
- د شاتړ تڼۍ: Activates or deactivates the display backlight. The backlight automatically turns off after 2 minutes of inactivity, but this can be overridden.

Image: A gloved hand adjusting the rotary dial of the Fluke 107 Multimeter, demonstrating its ergonomic design.
د اندازه کولو دندې
The meter is auto-ranging by default for most functions, simplifying operation.
- والیtagد e اندازه کول (AC/DC):
- روټري غوټۍ ته وګرځوئ V~ د AC حجم لپارهtage یا V- د DC حجم لپارهtage.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- Apply the test probes across the circuit or component to measure voltage.
- د اوسني اندازه کول (AC/DC):
- روټري غوټۍ ته وګرځوئ A~ (AC) or A- (DC). Use the yellow button to toggle between AC and DC if needed.
- Connect the red test lead to the A (10A FUSED) jack and the black test lead to the COM jack.
- مهم: Connect the meter in series with the circuit to measure current. Ensure the circuit is de-energized before connecting the meter.
- د مقاومت اندازه کول (Ω):
- روټري غوټۍ ته وګرځوئ Ω.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- Apply the test probes across the component. Ensure the circuit is de-energized.
- د دوام ازموینه:
- روټري غوټۍ ته وګرځوئ Ω. Press the yellow button until the continuity icon (speaker symbol) appears.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- A continuous beep indicates a complete circuit (resistance less than 70Ω). "OL" indicates an open circuit.
- د ډایډ ټیسټ:
- روټري غوټۍ ته وګرځوئ Ω. Press the yellow button until the diode icon (arrow with line) appears.
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- Place the red probe on the anode and black probe on the cathode of the diode. The display shows the forward voltage drop. Reverse the probes; "OL" should be displayed for a good diode.
- د ظرفیت اندازه کول:
- Turn the rotary knob to the capacitance symbol (--||-).
- Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
- مهم: Discharge capacitors before connecting them to the meter. Apply probes across the capacitor. Readings may take up to 18 seconds to stabilize.
- Frequency (Hz) and Duty Cycle (%) Measurement:
- Select AC Volts or AC Amps فعالیت.
- فشار ورکړئ هرټز % button to display frequency. Press again for duty cycle. Press a third time to return to voltage/current display.
د بریښنا بند
The meter automatically powers off after 20 minutes of inactivity to conserve battery life. This feature can be disabled if continuous operation is required.
ساتنه
پاکول
قضیه د اعلان سره پاک کړئamp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and free from scratches.
د بیټرۍ بدلول
Refer to the "Battery Installation" section under Setup for detailed instructions. Replace batteries when the low battery indicator appears on the display.
Fuse Check and Replacement
The Fluke 107 has a single internal fuse for the Amps function. To check the fuse:
- د انتخاب کونکي سویچ ته وګرځوئ Ω موقعیت
- Plug the red test lead into the VΩHz jack.
- Insert the probe tip of the red test lead into the A (10A FUSED) jack until electrical contact is made.
- A reading of less than 0.5Ω indicates a good fuse. An "OL" reading indicates a blown fuse that requires replacement.
Fuse replacement requires opening the meter case by removing three screws. It is recommended that fuse replacement be performed by qualified personnel or a Fluke service center.
د ستونزو حل کول
| ستونزه | احتمالي لامل | د حل لاره |
|---|---|---|
| "OL" (اوورلوډ) ښودل شوی | Input value exceeds selected range; open circuit in continuity/diode test; blown fuse in current mode. | Ensure correct function/range is selected. Check for open circuits. Check fuse in current mode. |
| هیڅ ښودنه نشته یا تیاره ښودنه نشته | Low battery; meter off; damaged display. | Replace batteries. Turn meter ON. Contact service if display is damaged. |
| ناسم لوستل | Low battery; incorrect function/range; poor test lead connection; external interference. | Replace batteries. Verify function/range. Ensure leads are fully inserted. Move away from strong electromagnetic fields. |
| د اوسني اندازه کولو نشته | Blown fuse; incorrect connection (not in series). | Check and replace fuse if necessary. Ensure meter is connected in series with the circuit. |
مشخصات
| پیرامیټر | ارزښت |
|---|---|
| Max Voltagد هر ټرمینل او د ځمکې ځمکې ترمنځ | 600V |
| د تازه کولو نرخ ښکاره کړئ | 3 updates per second |
| د بیټرۍ ډول | 2 x AAA batteries (Alkaline or Lithium recommended) |
| د بیټرۍ ژوند | لږترلږه 200،XNUMX ساعتونه |
| د عملیاتي حرارت درجه | له 0°C څخه تر 40°C (32°F څخه تر 104°F) |
| DC Volts Ranges | 6.000V, 60.00V, 600.0V (Accuracy: 0.5% + 3 counts) |
| AC Volts Ranges | 6.000V, 60.00V, 600.0V (Accuracy: 1% + 3 counts) |
| ACmV Range | 600.0mV (Accuracy: 3% + 3 counts) |
| DC Amps Ranges | 4.000A, 10.00A (Accuracy: 1.5% + 3 counts) |
| AC Amps Ranges | 4.000A, 10.00A (Accuracy: 1.5% + 3 counts) |
| د مقاومت حدونه | 400.0Ω, 4.000kΩ, 40.00kΩ, 400.0kΩ, 4.000MΩ, 30.00MΩ (Accuracy: 0.5% + 2 or 3 counts, 1.5% + 3 counts for 40MΩ) |
| د ظرفیت حدود | 50.00nF, 500.0nF, 5.000µF, 50.00µF, 500.0µF, 1000µF (Accuracy: 2% + 5 counts on two lowest, 5% + 5 counts on higher) |
| د فریکونسۍ حدود | 50.00Hz, 500.0Hz, 5.000kHz, 50.00kHz, 100.0kHz (Accuracy: 0.1% + 3 counts) |
| د دندې سایکل | 1% ~ 99% (Accuracy: 1% typical) |
| Diode Test Range | 2.000V (Accuracy: 10%) |
| د محصول ابعاد | 8.27 x 11 x 2.17 انچه؛ 7.05 اونس |
تضمین او ملاتړ
The Fluke 107 Digital Multimeter comes with a 1-year manufacturer warranty. For warranty claims, technical support, or service, please contact Fluke customer service or visit the official Fluke website. Ensure you have your product model number and purchase details available.
For additional resources and detailed user manuals, please refer to the official Fluke support channels.