د فلوک ۱۰۷ AC/DC اوسني لاسي ډیجیټل ملټي میټر کارونکي لارښود

ماډل: FLUKE-107

پیژندنه

The Fluke 107 is a compact, handheld digital multimeter designed for basic electrical measurements. It provides accurate readings for voltage, current, resistance, capacitance, frequency, and duty cycle, along with continuity and diode test functions. Its portable design makes it suitable for various applications, from professional use to hobbyist projects.

د فلوک ۱۰۱ ډیجیټل ملټي میټر مخکینۍ برخه view

انځور: مخکینۍ برخه view of the Fluke 107 Digital Multimeter, displaying its screen, rotary dial, and function buttons.

د خوندیتوب معلومات

د بریښنایی ازموینې تجهیزاتو کارولو پرمهال تل د خوندیتوب احتیاطي تدابیر مراعات کړئ. د دې کولو کې پاتې راتلل ممکن د ازموینې لاندې میټر یا تجهیزاتو ته د ټپي کیدو یا زیان لامل شي.

په بکس کې څه دي

The Fluke 107 package typically includes the following components:

Fluke 107 Multimeter with test leads and magnetic strap

Image: The Fluke 107 Multimeter displayed alongside its included test leads and magnetic lanyard.

چمتو کول

د بیټرۍ نصب کول

The Fluke 107 comes with two AAA batteries pre-installed. If replacement is needed:

  1. ډاډ ترلاسه کړئ چې ملټي میټر بند دی.
  2. د میټر په شا کې د بیټرۍ کڅوړه ومومئ.
  3. Open the battery compartment cover by twisting the lock and sliding it open.
  4. Remove the old batteries and insert two new AAA batteries, observing the correct polarity (+/-).
  5. د بیټرۍ کمپارټ پوښ په خوندي ډول وتړئ.

د ټیسټ لیډونو سره وصل کول

The Fluke 107 has three recessed banana jacks:

Always connect the black test lead to the COM jack. Connect the red test lead to the appropriate jack based on the measurement you intend to perform.

Using the Smart Strap Magnetic Lanyard

The included Smart Strap allows for hands-free operation by attaching the meter to a ferrous metal surface or by configuring it as a stand. The strap has a slot that fits into the meter's case and secures with Velcro. The magnetic end can then be used to attach the meter to metal surfaces or to itself to form a viewing stand.

عملیاتي لارښوونې

کنترول ختم شوview

The Fluke 107 features a central rotary selector knob and three soft-touch buttons:

Hand in glove operating Fluke 107 Multimeter

Image: A gloved hand adjusting the rotary dial of the Fluke 107 Multimeter, demonstrating its ergonomic design.

د اندازه کولو دندې

The meter is auto-ranging by default for most functions, simplifying operation.

  1. والیtagد e اندازه کول (AC/DC):
    • روټري غوټۍ ته وګرځوئ V~ د AC حجم لپارهtage یا V- د DC حجم لپارهtage.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • Apply the test probes across the circuit or component to measure voltage.
  2. د اوسني اندازه کول (AC/DC):
    • روټري غوټۍ ته وګرځوئ A~ (AC) or A- (DC). Use the yellow button to toggle between AC and DC if needed.
    • Connect the red test lead to the A (10A FUSED) jack and the black test lead to the COM jack.
    • مهم: Connect the meter in series with the circuit to measure current. Ensure the circuit is de-energized before connecting the meter.
  3. د مقاومت اندازه کول (Ω):
    • روټري غوټۍ ته وګرځوئ Ω.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • Apply the test probes across the component. Ensure the circuit is de-energized.
  4. د دوام ازموینه:
    • روټري غوټۍ ته وګرځوئ Ω. Press the yellow button until the continuity icon (speaker symbol) appears.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • A continuous beep indicates a complete circuit (resistance less than 70Ω). "OL" indicates an open circuit.
  5. د ډایډ ټیسټ:
    • روټري غوټۍ ته وګرځوئ Ω. Press the yellow button until the diode icon (arrow with line) appears.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • Place the red probe on the anode and black probe on the cathode of the diode. The display shows the forward voltage drop. Reverse the probes; "OL" should be displayed for a good diode.
  6. د ظرفیت اندازه کول:
    • Turn the rotary knob to the capacitance symbol (--||-).
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • مهم: Discharge capacitors before connecting them to the meter. Apply probes across the capacitor. Readings may take up to 18 seconds to stabilize.
  7. Frequency (Hz) and Duty Cycle (%) Measurement:
    • Select AC Volts or AC Amps فعالیت.
    • فشار ورکړئ هرټز % button to display frequency. Press again for duty cycle. Press a third time to return to voltage/current display.

د بریښنا بند

The meter automatically powers off after 20 minutes of inactivity to conserve battery life. This feature can be disabled if continuous operation is required.

ساتنه

پاکول

قضیه د اعلان سره پاک کړئamp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and free from scratches.

د بیټرۍ بدلول

Refer to the "Battery Installation" section under Setup for detailed instructions. Replace batteries when the low battery indicator appears on the display.

Fuse Check and Replacement

The Fluke 107 has a single internal fuse for the Amps function. To check the fuse:

  1. د انتخاب کونکي سویچ ته وګرځوئ Ω موقعیت
  2. Plug the red test lead into the VΩHz jack.
  3. Insert the probe tip of the red test lead into the A (10A FUSED) jack until electrical contact is made.
  4. A reading of less than 0.5Ω indicates a good fuse. An "OL" reading indicates a blown fuse that requires replacement.

Fuse replacement requires opening the meter case by removing three screws. It is recommended that fuse replacement be performed by qualified personnel or a Fluke service center.

د ستونزو حل کول

ستونزهاحتمالي لاملد حل لاره
"OL" (اوورلوډ) ښودل شویInput value exceeds selected range; open circuit in continuity/diode test; blown fuse in current mode.Ensure correct function/range is selected. Check for open circuits. Check fuse in current mode.
هیڅ ښودنه نشته یا تیاره ښودنه نشتهLow battery; meter off; damaged display.Replace batteries. Turn meter ON. Contact service if display is damaged.
ناسم لوستلLow battery; incorrect function/range; poor test lead connection; external interference.Replace batteries. Verify function/range. Ensure leads are fully inserted. Move away from strong electromagnetic fields.
د اوسني اندازه کولو نشتهBlown fuse; incorrect connection (not in series).Check and replace fuse if necessary. Ensure meter is connected in series with the circuit.

مشخصات

پیرامیټرارزښت
Max Voltagد هر ټرمینل او د ځمکې ځمکې ترمنځ600V
د تازه کولو نرخ ښکاره کړئ3 updates per second
د بیټرۍ ډول2 x AAA batteries (Alkaline or Lithium recommended)
د بیټرۍ ژوندلږترلږه 200،XNUMX ساعتونه
د عملیاتي حرارت درجهله 0°C څخه تر 40°C (32°F څخه تر 104°F)
DC Volts Ranges6.000V, 60.00V, 600.0V (Accuracy: 0.5% + 3 counts)
AC Volts Ranges6.000V, 60.00V, 600.0V (Accuracy: 1% + 3 counts)
ACmV Range600.0mV (Accuracy: 3% + 3 counts)
DC Amps Ranges4.000A, 10.00A (Accuracy: 1.5% + 3 counts)
AC Amps Ranges4.000A, 10.00A (Accuracy: 1.5% + 3 counts)
د مقاومت حدونه400.0Ω, 4.000kΩ, 40.00kΩ, 400.0kΩ, 4.000MΩ, 30.00MΩ (Accuracy: 0.5% + 2 or 3 counts, 1.5% + 3 counts for 40MΩ)
د ظرفیت حدود50.00nF, 500.0nF, 5.000µF, 50.00µF, 500.0µF, 1000µF (Accuracy: 2% + 5 counts on two lowest, 5% + 5 counts on higher)
د فریکونسۍ حدود50.00Hz, 500.0Hz, 5.000kHz, 50.00kHz, 100.0kHz (Accuracy: 0.1% + 3 counts)
د دندې سایکل1% ~ 99% (Accuracy: 1% typical)
Diode Test Range2.000V (Accuracy: 10%)
د محصول ابعاد8.27 x 11 x 2.17 انچه؛ 7.05 اونس

تضمین او ملاتړ

The Fluke 107 Digital Multimeter comes with a 1-year manufacturer warranty. For warranty claims, technical support, or service, please contact Fluke customer service or visit the official Fluke website. Ensure you have your product model number and purchase details available.

For additional resources and detailed user manuals, please refer to the official Fluke support channels.

اړوند اسناد - فلوک-۱۱۵

مخکېview فلوک ۱۰۷ لاسي CAT III ډیجیټل ملټي میټر - تخنیکي مشخصات
د فلوک ۱۰۷ لاسي CAT III ډیجیټل ملټي میټر لپاره تفصيلي تخنیکي مشخصات، ځانګړتیاوې، او عمومي معلومات. د بریښنا اندازه کول، د خوندیتوب درجه بندي، او د امر کولو توضیحات پکې شامل دي.
مخکېview فلوک 107 CAT III ډیجیټل ملټي میټر مشخصات en Kenmerken
Gedetailleerde specifications, kenmerken en technische gegevens voor de Fluke 107 CAT III ډیجیټل ملټي میټر په handpalmformaat کې. د EURO-INDEX diensten په اړه د الیکټریش او الجیمین مشخصات، afmetingen، تضمین او معلومات شامل دي.
مخکېview فلوک ۱۰۶/۱۰۷ د پام سایز ډیجیټل ملټي میټرونه: تخنیکي مشخصات او ځانګړتیاوې
د فلوک ۱۰۶ او ۱۰۷ پام لرونکي ډیجیټل ملټي میټرونو لپاره تفصيلي تخنیکي مشخصات، د محصول مهم ټکي، او عمومي معلومات. د دوی د بریښنایی مشخصاتو، دقت، ځانګړتیاو، او شامل تجهیزاتو په اړه زده کړه وکړئ.
مخکېview د فلوک ۱۰۶/۱۰۷ ډیجیټل ملټي میټرونو کارونکي لارښود
د فلوک ۱۰۶ او ۱۰۷ ډیجیټل ملټي میټرونو لپاره جامع کارونکي لارښود، د خوندیتوب معلومات، وسایل او نور پوښښ کويview، اندازه کول، ساتنه، او مشخصات.
مخکېview د بریښنایی موټرو د چارج کولو سټیشنونو لپاره د فلوک FEV100 اډاپټر کټ: تخنیکي معلومات او مشخصات
د فلوک FEV100 اډاپټر کټ لپاره تخنیکي مشخصات، ځانګړتیاوې، او د ازموینې پروسیجرونه وپلټئ، چې د بریښنایی موټرو چارج کولو سټیشنونو (EVSEs) په خوندي او مؤثره توګه ازموینې لپاره ډیزاین شوی. د خوندیتوب معلومات، مطابقت، او د امر کولو توضیحات پکې شامل دي.
مخکېview فلوک ۱۱۰ ټرو-آر ایم ایس ملټي میټر: تخنیکي مشخصات او ځانګړتیاوې
د فلوک ۱۱۰ کمپیکټ ټرو-آر ایم ایس ملټي میټر تفصيلي مشخصات او ځانګړتیاوې، چې د دقیق بریښنایی نصبولو او ستونزو حل کولو لپاره ډیزاین شوي. دقت، د خوندیتوب درجه بندي، او شامل شوي لوازمات پکې شامل دي.