OLMO OS-24SRW-230VI & OS-SR24-230VO

OLMO 24,000 BTU Ductless Mini Split Air Conditioner & Heat Pump

Instruction Manual for Models OS-24SRW-230VI & OS-SR24-230VO

19.5 SEER2 – 230V Inverter System – Pre-Charged with R-32

پیژندنه

This manual provides essential information for the installation, operation, and maintenance of your OLMO 24,000 BTU Ductless Mini Split Air Conditioner and Heat Pump. This system is designed to provide efficient heating and cooling for various spaces, featuring a 19.5 SEER2 rating and a 230V inverter system. It comes pre-charged with R-32 refrigerant and includes a 16-foot installation kit. Please read this manual thoroughly before installation and use to ensure proper function and safety.

OLMO 24,000 BTU Ductless Mini Split Air Conditioner and Heat Pump system with indoor unit, outdoor unit, remote, and smart app interface.

Figure 1: Complete OLMO Mini Split System with Indoor and Outdoor Units, Remote, and Smart App.

شاملې برخې

Your OLMO Mini Split system includes the following components for a comprehensive installation:

  • OLMO 24,000 BTU Single Zone Outdoor Condenser: 19.5 SEER2, 230V.
  • One Wall Mount Air Handler: داخلي واحد.
  • Smart Kit: For controlling your system via smartphone app.
  • 16FT Insulated Copper Line Set: Pre-flared for easier connection.
  • 16FT Communication Cable: For connecting indoor and outdoor units.
  • 16FT Drainage Extension: Designed for no-kink performance.
  • ریموټ کنټرول: د اسانه عملیاتو لپاره.
  • Small Accessories: Various parts for professional installation.
Diagram showing all components included in the OLMO Mini Split package: indoor unit, outdoor condenser, 16ft pre-flared and insulated copper line set, 4/16 AWG connecting cables, and 16ft drainage extension with small accessories.

شکل 2: مفصل view of included components for the OLMO Mini Split system.

تنظیم او نصب کول

مهم: This is not a DIY system. Professional installation is required to ensure proper function, safety, and warranty validity. The system comes pre-charged with R-32 refrigerant.

Outdoor Unit Placement and Connections

The outdoor condenser unit should be placed on a stable, level surface or mounted securely using appropriate brackets. Ensure adequate clearance around the unit for proper airflow and maintenance. The 16FT insulated copper line set, communication cable, and drainage extension are provided for connecting the indoor and outdoor units.

تړل view of the OLMO outdoor condenser unit, showing the fan grille and the OLMO logo in red.

Figure 3: OLMO Outdoor Condenser Unit.

Comparison image showing a 'no kink' rubberized drainage hose with plastic coil inserts (checked) versus a standard plastic hose (crossed out).

Figure 4: No-Kink Drainage Extension included with the system.

د داخلي واحد نصب کول

The indoor air handler should be mounted on a wall in a location that allows for optimal air distribution and minimal obstruction. Consult with your professional installer for the best placement in your space.

تړل view of the OLMO indoor air handler unit, showing the front panel and the OLMO logo.

Figure 5: OLMO Indoor Air Handler Unit.

عملیاتي لارښوونې

Your OLMO Mini Split system can be operated using the included remote control or via the smartphone app (Smart Kit required).

د ریموټ کنټرول دندې

The remote control allows you to adjust various settings for optimal comfort:

  • پاور آن/بند: واحد فعال یا غیر فعالوي.
  • د موډل انتخاب: Choose between Cool, Heat, Fan, Auto, and Dry modes.
  • د حرارت درجه تنظیمول: خپل مطلوب تودوخه تنظیم کړئ.
  • د فین سرعت: Adjust the fan speed (multiple settings available).
  • د سوینګ فعالیت: Control the louver movement for air distribution.
  • د خوب حالت: Optimizes settings for comfortable sleep.
  • د توربو حالت: Provides rapid cooling or heating.
  • د ایکو حالت: د انرژۍ سپمولو عملیات.
  • ټایمر: Set schedules for turning the unit on or off.
  • د ځان پاکولو حالت: د داخلي واحد لپاره د ځان پاکولو دوره پیلوي.
  • د LED ښودنه: Turn the unit's LED display on or off for undisturbed sleep.

Smart Control (App)

With the included Smart Kit, you can control your OLMO Mini Split system from anywhere using your smartphone. Download the official OLMO remote app from your device's app store:

Image showing a smartphone displaying the OLMO remote app interface and QR codes for downloading the app from iOS and Android app stores.

Figure 6: Download the OLMO Remote App for Smart Control.

کلیدي ځانګړتیاوې

  • Powerful & Efficient Climate Control: Provides high-performance heating and cooling for large rooms, open spaces, and light commercial areas.
  • All-Season Comfort: Operates efficiently in a wide temperature range, ensuring consistent comfort in both summer and winter. Ideal for garages, basements, additions, and converted living spaces.
  • خاموش عملیات: Designed for quiet indoor performance, minimizing noise while maximizing airflow.
  • ښکلی ډیزاین: Modern aesthetics allow the ductless unit to fit seamlessly into your room.
  • تغیر سرعت: Optimizes energy consumption and comfort.
Indoor OLMO mini split unit mounted on a wall in a modern living space, highlighting its sleek design and quiet operation.

Figure 7: OLMO Mini Split Unit in a modern interior setting.

مشخصات

مشخصاتارزښت
د برانډ نومELM
د ماډل معلوماتOS-24SRW-230VI & OS-SR24-230VO
د محصول ابعاد40 x 48 x 40 انچه
د توکي ماډل شمیرهOS-24SRW-230VI & OS-SR24-230VO
موثریتلوړ موثریت
ظرفیت۱ ټنه (۱۲۰۰۰ BTU)
د لګولو ډولسلیټ سیسټم
د فارم فکتورکوچنی ویش
ځانګړي ځانګړتیاوېSilent Mode, Variable Speed
رنګسپین
والیtage230 وولټ (AC)
شاملې برخېComes as a Combo Set
د یخولو ځواک24000 برتانوي حرارتي واحدونه
د موسمي انرژۍ موثریت تناسب (SEER)19.5
یخچالR-32
د بریښنا سرچینهد بریښنا تار شوی
Detailed specifications table for various OLMO mini split models, including power supply, capacity, SEER2, HSPF4, dimensions, noise levels, and refrigerant type.

Figure 8: Comprehensive Technical Specifications.

ساتنه

Regular maintenance is crucial for the longevity and efficient operation of your OLMO Mini Split system. While professional servicing is recommended annually, some basic tasks can be performed by the user:

  • د فلټر پاکول: The indoor unit's air filters should be cleaned regularly (e.g., monthly, or more frequently with heavy use) to maintain airflow and air quality. Refer to your professional installer's instructions for filter removal and cleaning procedures.
  • Outdoor Unit Clearance: Ensure the outdoor unit remains free of debris, leaves, and other obstructions that could impede airflow.
  • Drainage Line Check: Periodically inspect the drainage line for any blockages or kinks to prevent water backup.

د ستونزو حل کول

If you experience any issues with your OLMO Mini Split system, please consult your professional installer or contact technical support. Common issues and initial checks may include:

  • ځواک نشته: Check the circuit breaker and ensure the unit is properly connected to its power source.
  • ناکافي سړه کول/تودوخه: Verify temperature settings, ensure filters are clean, and check for any obstructions to airflow.
  • غیر معمولي غږونه: Minor operational sounds are normal, but loud or persistent noises may indicate an issue requiring professional inspection.
  • د اوبو جریان: Check the drainage line for blockages or improper slope.

For complex issues, always contact a qualified HVAC technician.

تضمین او ملاتړ

Your OLMO Mini Split system comes with a limited warranty:

  • کمپرسور: د 5 کلونو محدود تضمین
  • برخې: د 2 کلونو محدود تضمین

Free US-based technical support is available should you ever need assistance. Please refer to your warranty documentation for full terms and conditions.

Indoor OLMO mini split unit mounted on a wall in a room with plants, showing Energy Star, UL Listed, AHRI Certified, and warranty badges for 5 years compressor and 2 years parts.

Figure 9: Certifications and Warranty Information.

اړوند اسناد - OS-24SRW-230VI & OS-SR24-230VO

مخکېview د اولمو د هوا کنډیشن سیسټمونه: د سیرا لړۍ مینی سپلایټونه، د دیوال له لارې، او د PTAC واحدونه
د OLMO د انرژۍ موثره هوایی کنډیشنرونو لړۍ وپلټئ، پشمول د انورټر ټیکنالوژۍ مینی سپلایټ سیسټمونه (سیرا لړۍ)، د دیوال له لارې AC، او بسته شوي ټرمینل هوایی کنډیشنرونه (PTAC). تفصيلي مشخصات، ځانګړتیاوې، او د محصول معلومات ومومئ.
مخکېview د اولمو دیوال نصب شوی د مینی سپلایټ هوایی کنډیشن سیسټم نصبولو لارښود
د اولمو دیوال نصب شوي کوچني سپلایټ هوایی کنډیشن سیسټمونو لپاره د نصبولو لارښود، د خوندیتوب لارښوونې، د داخلي او بهرني واحدونو لپاره د ځای انتخاب، او د نصب کولو پلیټونو، پایپونو او بریښنایی اتصالاتو لپاره د نصبولو تفصيلي مرحلې پوښي. د ماډل شمیرې OS-09SRW-115VI څخه تر OS-36SRW-230VO پورې شامل دي.
مخکېview د اولمو سیرا لړۍ ریموټ کنټرولر لارښوونې
د اولمو سیرا لړۍ واحد زون هوایی کنډیشن ریموټ کنټرولر چلولو لپاره جامع لارښوونې، چې مختلف حالتونه، دندې، او د ستونزو حل کول پوښي.
مخکېview د OLMO دیوال نصب شوی مینی سپلیټ هوایی کنډیشن سیسټم: د کارولو او نصبولو لارښود
د OLMO ملټي سیرا دیوال نصب شوي مینی سپلایټ ایر کنډیشن سیسټمونو لپاره جامع کارونې او نصبولو لارښود، چې ماډلونه OS-RM09SW-230VI، OS-RM12SW-230VI، OS-RM18SW-230VI، او OS-RM24SW-230VI پوښي. د عملیاتو او تنظیم لپاره اړین معلومات چمتو کوي.
مخکېview د اولمو ملټي زون ملټي سیرا لړۍ د نصبولو لارښود
دا د نصبولو لارښود د OLMO ملټي زون ملټي SIERRA لړۍ دیوال نصب شوي مینی سپلایټ هوایی کنډیشن سیسټم لپاره تفصيلي لارښوونې چمتو کوي. دا د خوندیتوب احتیاطي تدابیر، د نصب کولو پروسیجرونه، د پایپ اړتیاوې، تارونه، او د OS-RMS18-230VO، OS-RMS27-230VO، OS-RMS36-230VO، او OS-RMS42-230VO ماډلونو لپاره د آزموینې منډې پوښي.
مخکېview د اولمو سیرا لړۍ مینی سپلایټ ایر کنډیشنر نصبولو لارښود
دا د نصبولو لارښود د OLMO واحد زون سیرا لړۍ دیوال نصب شوي مینی سپلیټ هوایی کنډیشن سیسټمونو تنظیم کولو لپاره جامع لارښوونې چمتو کوي. دا د خوندیتوب احتیاطي تدابیر، د برخو پیژندنه، عملیات، د نصب کولو مرحلې، ازموینه، ساتنه، او ستونزې حل کول پوښي.