OLMO OS-18SRW-230VI & OS-SR18-230VO

د اولمو ۱۸۰۰۰ BTU ډکټلیس مینی سپلایټ ایر کنډیشنر او د تودوخې پمپ کارونکي لارښود

Model: OS-18SRW-230VI & OS-SR18-230VO

1. پیژندنه

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your OLMO 18,000 BTU Ductless Mini Split Air Conditioner and Heat Pump. Please read this manual thoroughly before installation and use, and retain it for future reference.

OLMO 18,000 BTU Mini Split system showing indoor unit, outdoor unit, remote control, and smartphone app interface.

Figure 1: OLMO 18,000 BTU Mini Split system with indoor unit, outdoor unit, remote, and app interface.

2. د خوندیتوب معلومات

Always adhere to basic safety precautions to reduce the risk of fire, electric shock, or injury. This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities unless supervised or instructed concerning its use by a person responsible for their safety.

2.1 عمومي خوندیتوب

  • مسلکي نصب ته اړتیا ده: This is not a DIY system. Installation must be performed by a qualified HVAC technician in accordance with all local and national electrical and safety codes. Improper installation can result in electric shock, fire, water leakage, or other hazards.
  • بریښنایی خوندیتوب: Ensure the unit is connected to a properly grounded power supply with the correct voltage (230V). Do not operate with wet hands or in wet conditions.
  • یخچال: This unit uses R-32 refrigerant. Only qualified personnel should handle refrigerant.
  • تصفیه: Maintain adequate clearance around both indoor and outdoor units for proper airflow and maintenance.
  • پاکول: د پاکولو یا ساتنې ترسره کولو دمخه بریښنا قطع کړئ.

3. د محصول اجزا

Your OLMO Mini Split system includes the following main components and installation accessories:

Diagram showing components included in the order: Single-Zone Sierra Series indoor unit with remote, outdoor condenser pre-charged with R32, 16ft pre-flared and insulated copper line set, 4/16 AWG connecting cables, and 16ft drainage extension with small accessories.

Figure 2: Included components for the OLMO Mini Split system.

  • داخلي واحد: Single-Zone Sierra Series wall-mount air handler.
  • Outdoor Condenser: Pre-charged with R-32 refrigerant.
  • ریموټ کنټرول: د اسانه عملیاتو لپاره.
  • 16FT Insulated Copper Line Set: Pre-flared for easier connection.
  • 16FT Communication Cable: For connecting indoor and outdoor units.
  • 16FT Drainage Extension: Designed to prevent kinking.
  • Small Accessories: Various parts for a complete installation.
Comparison image showing 'No Kink Drainage Extension' with a rubberized hose (included) versus a standard plastic hose (other brands).

Figure 3: Included rubberized drainage hose designed to prevent kinking.

4. د نصبولو لارښوونې

The OLMO Mini Split system requires professional installation. The outdoor condenser comes pre-charged, and a 16-foot installation kit is included to facilitate the process. Ensure the installation site meets all requirements for proper drainage, electrical connections, and structural support.

4.1 د نصب کولو دمخه چکونه

  • Verify that the power supply matches the unit's requirements (230V).
  • Ensure sufficient space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
  • Confirm that the wall or mounting surface for the indoor unit can support its weight.

4.2 Key Installation Steps (Overview for Technician)

  1. Mount the indoor unit securely on the wall.
  2. Install the outdoor condenser on a stable, level surface, ensuring proper vibration isolation.
  3. Connect the pre-flared copper line set between the indoor and outdoor units.
  4. Connect the communication cable and power wiring according to the wiring diagram.
  5. Install the drainage hose, ensuring a continuous downward slope for proper condensate removal.
  6. Evacuate the system using a vacuum pump to remove air and moisture.
  7. Open the refrigerant valves on the outdoor unit.
  8. Perform a leak check and test run the system.

5. عملیاتي لارښوونې

Your OLMO Mini Split system offers various modes and features for optimal climate control. The unit can be operated using the included remote control or via the OLMO Remote App on your smartphone.

5.1 د ریموټ کنټرول عملیات

The remote control allows you to adjust temperature, change operating modes (Cool, Heat, Fan, Dry, Auto), set fan speed, and activate special features like Sleep Mode or Timer functions. Refer to the remote control's dedicated manual for detailed button functions.

5.2 Smart Control via App

The system includes a Smart Kit, enabling control from anywhere using your smartphone and the OLMO Remote App. Download the app from your device's app store:

Image demonstrating the OLMO Remote App on a smartphone, with QR codes for iOS and Android app downloads.

Figure 4: OLMO Remote App interface and download QR codes.

Follow the in-app instructions to connect your unit and access features such as remote temperature adjustment, mode selection, scheduling, and diagnostics.

Living room setting with the OLMO indoor unit installed, highlighting 'Powerful Solutions' features like Smart Connect, Remote Included, Sleep Mode, Turbo/Eco Modes, Multiple Fan Speeds, Timer, Louver Auto Swing, Self Clean Mode, and LED Display.

Figure 5: OLMO Mini Split features for enhanced comfort and control.

5.3 Key Operating Features

  • All-Season Comfort: Provides efficient heating and cooling across a wide temperature range.
  • خاموش عملیات: Designed for minimal noise during indoor performance.
  • غلي حالت: Reduces fan speed for ultra-quiet operation.
  • تغیر سرعت: Inverter technology adjusts compressor speed for precise temperature control and energy efficiency.
  • د خوب حالت: Adjusts temperature automatically for comfortable sleep and energy savings.
  • ټایمر: واحد په ځانګړو وختونو کې د فعالولو یا بندولو لپاره پروګرام کړئ.
  • Louver Auto Swing: Automatically adjusts airflow direction for even distribution.
  • د ځان پاکولو حالت: Helps prevent mold and bacteria growth on the indoor coil.
  • د LED ښودنه: د ترتیباتو او حالت روښانه اشاره وړاندې کوي.

6. ساتنه

Regular maintenance ensures optimal performance and longevity of your OLMO Mini Split system. Always disconnect power to the unit before performing any maintenance.

6.1 Indoor Unit Maintenance

  • د هوا فلټر پاکول: The indoor unit's air filters should be cleaned every 2-4 weeks, or more frequently depending on usage and air quality. Gently remove the filters and wash them with lukewarm water and mild detergent. Allow them to dry completely before reinserting.
  • بهرنۍ پاکوالی: د داخلي واحد بهرنۍ برخه د نرم، ډ سره پاک کړئamp ټوکر د سختو کیمیاوي موادو یا خړوبولو پاکونکو څخه کار مه اخلئ.

۶.۲ د بهرنۍ واحد ساتنه

  • د کویل پاکول: Periodically inspect the outdoor coil for dirt, leaves, and debris. Carefully clean the coil with a soft brush or water hose. Avoid bending the fins.
  • تصفیه: Ensure that vegetation, snow, or other obstructions do not block airflow around the outdoor unit.
  • د اوبو ایستل: Check the condensate drain line for blockages.

7. ستونزه حل کول

د تخنیکي مالتړ سره اړیکه نیولو دمخه، بیاview لاندې عامې ستونزې او حل لارې:

ستونزهاحتمالي لاملد حل لاره
واحد نه خلاصیږيبرېښنا نشته، سرکټ بریکر ټکر شوی، د ریموټ کنټرول بیټرۍ ټیټې دي.د برېښنا رسولو وګورئ، د سرکټ بریکر بیا تنظیم کړئ، د ریموټ بیټرۍ بدل کړئ.
ناکافي یخول/تودوخهDirty air filters, blocked outdoor unit, incorrect mode setting, low refrigerant.Clean air filters, clear obstructions from outdoor unit, verify mode, contact technician for refrigerant check.
غیر معمولي شورLoose parts, fan obstruction, refrigerant flow noise (normal).Inspect for loose parts or obstructions. If persistent or loud, contact technician.
د داخلي واحد څخه د اوبو لیکیدلBlocked drain line, improper installation.Check and clear drain line. If issue persists, contact technician.

If troubleshooting steps do not resolve the issue, please contact OLMO technical support.

8. مشخصات

The following table outlines the key specifications for the OLMO 18,000 BTU Ductless Mini Split Air Conditioner and Heat Pump (Model OS-18SRW-230VI & OS-SR18-230VO).

Detailed specifications table for various OLMO indoor and outdoor models, including power supply, capacity, cooling/heating BTUs, SEER2, HSPF, dimensions, noise levels, refrigerant type, and pipe lengths.

Figure 6: Comprehensive specifications for OLMO Mini Split models.

مشخصاتارزښت
برانډELM
د ماډل معلوماتOS-18SRW-230VI & OS-SR18-230VO
د یخولو ځواک۷،۵۰۰ برتانوي حرارتي واحدونه (BTU)
موثریت (SEER2)21 SEER2
ظرفیت1.5 ټنه
والیtage230 وولټ (AC)
یخچالR-32
د لګولو ډولسلیټ سیسټم
د محصول ابعاد40 x 48 x 40 inches (Overall)
ځانګړي ځانګړتیاوېSilent Mode, Variable Speed
رنګسپین

9. تضمین او ملاتړ

Your OLMO Mini Split system is backed by a limited warranty:

  • کمپرسور: د 5 کلونو محدود تضمین
  • برخې: د 2 کلونو محدود تضمین
OLMO Mini Split system with certifications (UL Listed, AHRI Certified, Energy Star, Blue Fin Condenser, NEEP) and warranty details (5 years compressor, 2 years parts).

Figure 7: Product certifications and warranty information.

For technical assistance or warranty claims, free US-based technical support is available. Please refer to your purchase documentation for contact details or visit the official OLMO webسایټ

اړوند اسناد - OS-18SRW-230VI & OS-SR18-230VO

مخکېview د اولمو د هوا کنډیشن سیسټمونه: د سیرا لړۍ مینی سپلایټونه، د دیوال له لارې، او د PTAC واحدونه
د OLMO د انرژۍ موثره هوایی کنډیشنرونو لړۍ وپلټئ، پشمول د انورټر ټیکنالوژۍ مینی سپلایټ سیسټمونه (سیرا لړۍ)، د دیوال له لارې AC، او بسته شوي ټرمینل هوایی کنډیشنرونه (PTAC). تفصيلي مشخصات، ځانګړتیاوې، او د محصول معلومات ومومئ.
مخکېview د اولمو دیوال نصب شوی د مینی سپلایټ هوایی کنډیشن سیسټم نصبولو لارښود
د اولمو دیوال نصب شوي کوچني سپلایټ هوایی کنډیشن سیسټمونو لپاره د نصبولو لارښود، د خوندیتوب لارښوونې، د داخلي او بهرني واحدونو لپاره د ځای انتخاب، او د نصب کولو پلیټونو، پایپونو او بریښنایی اتصالاتو لپاره د نصبولو تفصيلي مرحلې پوښي. د ماډل شمیرې OS-09SRW-115VI څخه تر OS-36SRW-230VO پورې شامل دي.
مخکېview د اولمو سیرا لړۍ ریموټ کنټرولر لارښوونې
د اولمو سیرا لړۍ واحد زون هوایی کنډیشن ریموټ کنټرولر چلولو لپاره جامع لارښوونې، چې مختلف حالتونه، دندې، او د ستونزو حل کول پوښي.
مخکېview د OLMO دیوال نصب شوی مینی سپلیټ هوایی کنډیشن سیسټم: د کارولو او نصبولو لارښود
د OLMO ملټي سیرا دیوال نصب شوي مینی سپلایټ ایر کنډیشن سیسټمونو لپاره جامع کارونې او نصبولو لارښود، چې ماډلونه OS-RM09SW-230VI، OS-RM12SW-230VI، OS-RM18SW-230VI، او OS-RM24SW-230VI پوښي. د عملیاتو او تنظیم لپاره اړین معلومات چمتو کوي.
مخکېview د اولمو ملټي زون ملټي سیرا لړۍ د نصبولو لارښود
دا د نصبولو لارښود د OLMO ملټي زون ملټي SIERRA لړۍ دیوال نصب شوي مینی سپلایټ هوایی کنډیشن سیسټم لپاره تفصيلي لارښوونې چمتو کوي. دا د خوندیتوب احتیاطي تدابیر، د نصب کولو پروسیجرونه، د پایپ اړتیاوې، تارونه، او د OS-RMS18-230VO، OS-RMS27-230VO، OS-RMS36-230VO، او OS-RMS42-230VO ماډلونو لپاره د آزموینې منډې پوښي.
مخکېview د اولمو سیرا لړۍ مینی سپلایټ ایر کنډیشنر نصبولو لارښود
This installation manual provides comprehensive guidance for setting up OLMO Single-Zone Sierra Series Wall Mounted Mini Split Air Conditioning Systems. It covers safety precautions, parts identification, operation, installation steps, testing, maintenance, and troubleshooting.