Grada RVP-P Rectangular Variable Air Volume Controller Instruction Manual

Grada RVP-P Rectangular Variable Air Volume Controller Instruction Manual

Grada-logo

Grada RVP-P Rectangular Variable Air Volume Controller

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-product

Rectangular control valve vav

  • VAV ensures volume flow control regulation by a given set-point. Set-point can be given as air volume flow or overpressure/underpressure.
  • Parametrization is carried out in the factory in accordance with clients request. Advantages of variable air volume dampers are high regulation precision and no maintainance required.

تفصیل

  • VAV دampers are used to control a variable or constant airflow volume in duct ventilation systems.
  • All VAV dampers are equipped with a compact VAV actuator, which has an in-built pressure differential sensor and PID logic control.
  • The actuator sensor is connected with rubber hoses to the measuring cross, which is used for measuring the duct airflow. By having real-time information about the volume airflow in the duct, VAVs can dynamically respond to the changes in the setpoint (temperature, C02 or humidity) and ensure optimized ventilation with the lowest possible energy consumption.

مواد

  • Casing and damper blade of the VAV damper are produced out of galvanized steel sheet. Sealing gaskets are produced out of EPDM rubber, and measuring cross is made out of aluminium tubes.

ابعاد

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-1 Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-2

محصول اوورVIEW

د موټرو چلول

  • LM 5 Nm
  • NM 10 Nm

MF 5 Nm actuator version (max dimensions 700 x 600)

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-5Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-3

TESTS AND CERTIFICATES

  • All our dampers are submitted to a number of tests by offi- Cial test institutes. Reports of these tests form the basis for the approvals of our dampers. Klimaoprema VAV dampers are also suitable for installation in buildings with high hygienic demands such as hospitals, clinics and pharmaceutical areas.
  • To confirm this, out products are tested by an independent Institute of Hygiene, based in Gelsenkirchen, Ruhr, and comply with directives and guidelines in VDI 6022.

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-4

with Belimo controller
Volume flow control regulation by a given set-point.
Factory parametrization in accordance with clients request.

  • High regulation precision.
  • No maintainance required.
  • Airtightness classes according to EN 1751, CO/C3
  • Hygiene certificate according to VDI 6022.

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-5

اختیارونه

  • Constant, variable, 3-stagای کنټرول
  • Single, master-slave and parallel modes of operation
  • Insulated casing (30mm)

MP- Belimo MP
MOD-BAC Belimo Modbus / Bacnet

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-6

Compact VAV solutions

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-7

  • If not otherwise specified, the regulator is set to standard factory values V and V min

Belimo motor drive

  • motor drives: Belimo (MP, ModBus/Bacnet power supply -AC 24V, 50/60 Hz – DC 24V
  • diagnostic socket for service and PC-Tool software

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-8 Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-9

ACTUATORS

کنټرول متغیرات

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-10

کلاسیک کنټرول

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-11

سرپرست

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-12

د عملیاتو مشخصات

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-13

د حرارت درجه اغیزه

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-14

د تارونو ډیاګرام

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-15

ACTUATORS

Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-16Grada-RVP-P-Rectangular-Variable-Air-Volume-Controller-fig-17

ساتنه

ټرانسپورټ

  • After arrival, check the VAV damper for transport damage and shortcomings. In case of any damage or shortcomings, immediately contact your supplier.

ذخیره

  • که چیرې دamper سمدلاسه نه دی نصب شوی:
  • هر ډول پوښ لرې کړئ.
  • د اور څخه ساتنهamper from dust and contamination.
  • Do not expose the VAV damper to the effects of weather – store the dampپه وچ ځای کې.
  • Do not store the unit below -20 oc or above 50 oc.

Please properly dispose of packaging material!

ساتنه او چلښت
Klimaoprema VAV dampers are designed with a fully enclosed drive mechanism outside of the duct and as such, do not require cleaning and regular maintenance.
However, the activation mechanism should be inspected for proper operation on a regular basis.

  • د d لږترلږه یو کلنی چیک چمتو کړئamper
  • After each intervention, provide a systematic cleaning of dust and especially the solenoid and its movable plate
  • وګورئ چې آیا د بریښنا ټرمینلونه کلک شوي دي
  • د پاکولو لارښوونه: د سپنج، اوبو یا یو نرم صابون سره پاک کړئ
  • Disinfection instruction: spray disinfectant (disinfectant may contain flammable alcohol; take precautions to avoid ignition)

د بدلون اجازه نشتهampers in any way nor perform any changes to their structure (except for the service procedures described in this manual) without the manufacturer’s consent.
د d لږترلږه یو کلنی چیک چمتو کړئamper. The functional test must be carried out in compliance with the basic maintenance principles of the European norms EN 13306, EN 15423 and ENI 5650.

کمیسون کول

  • Carefully unpack RVP-P – be careful of sharp edges and do not use excessive force for unpacking
  • Inspect the product – check the volume flow dampد زیان لپاره
  • Installation of the volume flow damper – according to the installation instructions
  • Before commissioning: check the product functions

دندې

  • Electric actuator: Signal testing – the dampد هغې تیغ باید وتړل شي/پرانستل شي

اسناد / سرچینې

PDF thumbnailRVP-P Rectangular Variable Air Volume Controller
Instruction Manual · sk22708, L N MV-D3-MF, L N MV-D3-MP, L N MV-D3-MOD, L N MV-D3-KNX, GL D B181.1E-3, GL D B181.1E-MO, GL D B181.1E-KN, GL D B181.1E-BA, 327V-024-05 10, 327V-025-05 10 -MB, RVP-P Rectangular Variable Air Volume Controller, RVP-P, Rectangular Variable Air Volume Controller, Variable Air Volume Controller, Air Volume Controller, Volume Controller, Controller