The SmartGen EP4300/EP4301 Engine Controller is a sophisticated CAN instrument designed for the control and data display of engines, particularly electric-controlled models. It facilitates essential functions such as engine start/stop, speed control, data measurement, and alarm display. Featuring a color LCD display and powered by 32-bit microprocessor technology, it offers precise measurement of various parameters, value adjustment, and threshold setting. Its compact structure, simple wiring, and high reliability make it suitable for diverse engine automation systems. Parameters can be adjusted directly from the front panel or via USB/RS485 ports using a PC.

مخکی view of SmartGen EP4300/EP4301 controller
شکل 1.1: مخکی view of the SmartGen EP4300/EP4301 controller, showing the color LCD display with RPM, temperature, and pressure readings, along with control buttons and a central knob.

2. ترتیب او نصب کول

2.1. خلاصول او معاینه کول

Carefully unpack the controller and inspect for any signs of damage. Ensure all components are present according to the packing list.

2.2. پورته کول

The controller is designed for panel mounting. Ensure adequate space for ventilation and access to rear connections.

2.3. د تارونو نښلول

Refer to the wiring diagram below for proper connection of power, sensors, auxiliary inputs/outputs, and communication ports (CANBUS, RS485, USB).

شاته view of SmartGen EP4300/EP4301 controller with labeled connection points
شکل ۷: تفصیلي شا view of the SmartGen EP4300/EP4301 controller, showing labeled connection points. These include: 1.A(+) 3.NC, 2.B(-) 3.NC (for RS485), Sensor 1, Sensor 2, MP1, MP2, 5.0V, GND, CAN H, CAN L, Sensor 3, 10.0V (+5V), GND, AUX INPUT 1-3, AUX OUTPUT 1-3, NC, and USB port. Ensure all connections are secure and correctly polarized.
شاته view of SmartGen EP4300/EP4301 controller showing ports
شکل 2.2: شاته view of the SmartGen EP4300/EP4301 controller, providing an overview of the connection ports including RS485, USB, and various input/output terminals.

Key Connection Points:

  • د بریښنا رسول: د بریښنا اصلي رسولو ټاکل شوي ترمینلونو سره وصل کړئ.
  • سینسرونه: Connect engine sensors (e.g., for RPM, temperature, pressure) to Sensor 1, Sensor 2, Sensor 3, MP1, and MP2 terminals as per your engine's requirements.
  • مرستندویه داخلې/آؤټ پټونه: Utilize AUX INPUT 1-3 and AUX OUTPUT 1-3 for additional control and monitoring functionalities.
  • کانبس: Connect CAN H and CAN L for CANBUS communication with compatible engine ECUs.
  • RS485: Use the RS485 terminals (A+ and B-) for serial communication, typically for PC connection or other devices.
  • USB: The USB port is available for direct PC connection for parameter configuration and firmware updates.

۱. لومړنی پاور اپ

After all connections are verified, apply power to the controller. The display should illuminate, and the system will initiate its startup sequence.

3. عملیات

3.1. د ښودلو انٹرفیس

The color LCD display provides real-time data and status information. Key indicators include:

  • RPM: په یوه دقیقه کې د انجن انقلابونه.
  • دحرارت درجه: Engine coolant or oil temperature.
  • فشار: Engine oil pressure.
  • د الارم نښه: Visual alerts for detected faults.
  • د چلولو حالت: Indicates if the engine is running, stopped, or in a specific mode.
  • Comm Indication: Status of communication links (e.g., CANBUS, RS485).
  • د بریښنا اشاره: Status of the controller's power supply.
SmartGen EP4300/EP4301 front panel with labeled indicators and display screens
Figure 3.1: Front panel of the SmartGen EP4300/EP4301 with labels for Alarm Indication, Running Status, Comm Indication, Power Indication, User-defined Buttons 1-4, and the central Knob. Also shown are various display screens including main engine parameters, auxiliary inputs/outputs status, total run time/starts, and high temperature warning.

3.2. Control Buttons and Knob

The controller features several buttons and a central knob for navigation and control:

  • User-defined Buttons (1-4): These buttons can be configured for specific functions as per the system's requirements.
  • غوټۍ: Used for navigating through menus, adjusting values, and confirming selections.

3.3. د پیرامیټر سمون

Most operational parameters and thresholds can be adjusted directly from the front panel using the knob and buttons. For advanced configuration or bulk adjustments, connect the controller to a PC via the USB or RS485 port and use the dedicated SmartGen software.

4. ساتنه

4.1. پاکول

Keep the controller's display and casing clean. Use a soft, dry cloth for cleaning. Avoid abrasive cleaners or solvents that may damage the surface or display.

4.2. د سافټویر تازه معلومات

په دوره یي ډول د تولید کونکي معاینه وکړئ website for firmware updates. Updates can be installed via the USB or RS485 port using a PC and the appropriate software. Always follow the update instructions carefully to avoid damaging the device.

۵. منظمې معاینې

  • Verify all wiring connections remain secure.
  • ډاډ ترلاسه کړئ چې ښودنه روښانه او د لوستلو وړ ده.
  • Test alarm functions periodically to confirm proper operation.

5. ستونزه حل کول

دا برخه د عامو ستونزو لپاره لارښوونې چمتو کوي. د پیچلو ستونزو لپاره، د تخنیکي ملاتړ سره اړیکه ونیسئ.

ستونزهاحتمالي لاملد حل لاره
ښودل خالي ديد برېښنا رسولو نشته؛ تړل شوی اړیکهCheck power input; Verify wiring connections
د سینسر ناسم لوستلFaulty sensor; Incorrect wiring; Calibration issueCheck sensor wiring; Replace sensor; Recalibrate sensor in settings
Communication error (RS485/CANBUS)Incorrect wiring; Baud rate mismatch; Device faultVerify communication wiring; Check baud rate settings; Consult manual for specific error codes
Engine fails to start/stopIncorrect control logic; Wiring issue to starter/fuel solenoidReview control parameters; Check output wiring to engine components

6. مشخصات

فیچرتفصیل
ماډلEP4300, EP4301
ښودلرنګ LCD
پروسیسر32-bit Microprocessor
د مخابراتو بندرونهCANBUS, RS485, USB
افعالEngine Start/Stop, Speed Control, Data Measurement, Alarm Display, Parameter Adjustment
د ژبې اختیارونهچینایي، انګلیسي
د بسته ابعاد (L x W x H)22 cm x 10 cm x 10 cm
د بسته وزن1.0 کیلو ګرامه

7. د کارن لارښوونې

  • د پیرامیټر بیک اپ: Before making significant changes to parameters, it is recommended to back up your current configuration using the PC software.
  • د فرم ویئر تازه معلومات: Always ensure the controller's firmware is up-to-date for optimal performance and access to the latest features.
  • د چاپیریال په اړه نظرونه: While robust, avoid exposing the controller to extreme temperatures, direct sunlight, or excessive moisture to prolong its lifespan.

8. تضمین او ملاتړ

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.

اړوند اسناد - EP4300, EP4301

مخکېview SmartGen SG485-2CAN: User Manual for Communication Interface Conversion Module
User manual for the SmartGen SG485-2CAN, a communication interface conversion module that converts RS485 to CANBUS interfaces. Details specifications, wiring, electrical connections, and dimensions.
مخکېview SmartGen HGM9510N/HGM9530N Paralleled Genset Controller User Manual
Comprehensive user manual for SmartGen HGM9510N and HGM9530N paralleled genset controllers. Learn about features, operation, specifications, wiring, protection, and commissioning for efficient generator synchronization and control.
مخکېview د SmartGen SGUE485 د مخابراتو انٹرفیس تبادله ماډل کارن لارښود
User manual for the SmartGen SGUE485, a communication interface conversion module that converts USB to isolated RS485. Details features, technical parameters, terminal descriptions, applications, and installation for generator control systems.
مخکېview د سمارټ جین HGM7000 لړۍ جینسیټ کنټرولر کارونکي لارښود
This user manual provides comprehensive information on the SmartGen HGM7000 series genset controllers, covering operation, specifications, installation, and troubleshooting for automated genset control systems.
مخکېview د SmartGen SG485-3 د انٹرفیس توسیع ماډل کارن لارښود
User manual for the SmartGen SG485-3 Interface Expansion Module. This document provides detailed specifications, wiring diagrams, connection examples, and installation guidelines for the RS485 communication module.
مخکېview SmartGen HGM6100LT Series Genset Controller User Manual
User manual for SmartGen HGM6100LT series genset controllers (HGM6110LT/HGM6120LT), detailing features, operation, specifications, and troubleshooting for automatic control and monitoring of generators in extreme environments.